• Title/Summary/Keyword: X-ray grid

Search Result 103, Processing Time 0.033 seconds

The analysis and design of X-ray cross sectional imaging system for PCB solder joint inspection (PCB 납땜 검사를 위한 X선 단층 영상 시스템의 해석 및 설계)

  • 노영준;강성택;김형철;김성권
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.109-112
    • /
    • 1996
  • The more integrated and smaller SMD are needed, new solder joints packaging technologies are developed in these days such as BGA(Ball Grid Array), Flip Chip, J-lead etc. But, it's unable to inspect solder joints in those devices by visual inspection methods, because they are hided by it's packages. To inspect those new SMD packages, an X-ray system for acquiring a cross-sectional image of a arbitrary plane is necessary. In this paper, an analysis for designing X-ray cross sectional imaging system is presented including the way for correcting the distortion of image intensifier. And we show computer simulation of that system with a simple PCB model to show it's usefulness in applying PCB solder joint inspection.

  • PDF

A Volume Reconstruction Algorithm and a Coordinate Calibration of an X-ray Three Dimensional Imaging System

  • Roh, Young-Jun;Cho, Hyung-Suck;Jeon, Hyoung-Jo;Kim, Hyeong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.63.3-63
    • /
    • 2001
  • Inspection and shape measurement of three-dimensional objects are widely needed in industries for quality monitoring and control. In this paper, we propose a three dimensional volume reconstruction method, which is an iterative method and as uniform and simulated algebraic reconstruction technique (USART). In this method, two or more x-ray images projected from different views are needed, and also the geometry of the imaging system need to be a priori identified well. That is to say, the relative locations between the x-ray source, imaging plane and the object should be determined exactly by calibration. To achieve this, we propose a series of coordinate calibration methods of the x-ray imaging system using grid pattern images. Some experimental results of these calibrations is presented and discussed in detail ...

  • PDF

Detection of Void Defects in Ball Grid Array X-ray Image Using a New Blob Filter (볼 그리드 배열 기판의 X-ray 영상에서의 새로운 덩어리 검출 필터를 이용한 기포 형태 결함 검출 방법)

  • Peng, Shao-Hu;Lee, Hye-Jung;Nam, Hyun-Do
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2005-2006
    • /
    • 2011
  • Due to the advantages of small sizes, more I/O ports, etc., Ball Grid Array (BGA) has been used in the production of printed circuit board (PCB). However, BGA voids can degrade the performance of the board and cause failure. To automatically detect the voids in X-ray image, a novel blob filter that makes use of the local image gradient magnitude is proposed in this paper. The utilization of the local image gradient magnitude makes the proposed filter invariant to the image brightness, void shape, void position, and component interference. Furthermore, different sizes of box filters are employed to analyze the image in multi-scale, and as a result, the proposed blob filter is robust to void size. Experimental results show that the proposed method can obtain void detection accuracy up to 96.104% while keep low false ratio.

  • PDF

A Study on the Performance Evaluation and Use Status of Grid (격자의 성능평가와 이용실태에 관한 연구)

  • Lee, Who-Min;Kim, Hak-Sung;Lee, Sang-Suk;Oh, Hyun-Joo;Kim, Young-Il;Lim, Han-Young;Kim, Heung-Tae;Lee, In-Ja;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.17 no.1
    • /
    • pp.55-63
    • /
    • 1994
  • We have conducted on experiment with a purpose to evaluate the performance of grids being used at hospitals in Seoul and adjacent cities of Seoul. The results are as follows; Reality of the grids use 1. The focused grids were 105 and the parallel grids were 6 among 111 grids subject to experimenting. 2. The grid interspace material was aluminium of 94 and the remains were wood and bakelite. 3. The umber of Korean products from five companies was 33 and the one of the foreign products was 34 from companies. The physical properties have been examined by the notice of Department of Health and Social Affairs. 4. The intensity of secondary radiation was the highest in 5 : 1 grid ratio. 5. The Bucky factor increased with the increase of grid ratio. The selectivity, the grid improvement factor of grids also increased with increase of the grid ratio. However, with 6 : 1 grid ratio those factors were decreased exceptionally. In measurement of grid density with screen determiners and the beam alignment. 6. In evaluation the results were satifisfied within, 20%. 7. The value of the scale and the value of measurement were within the range of standard deviation, but the value of 103 lines were outranged from the standard deviation with all grid ratio except of 6 : 1 grid ratio.

  • PDF

Monte Carlo Simulation-Based Mammographic Anti-Scatter Grids to Evaluate Performance of Digital Mammography Detector (디지털 맘모 디텍터 성능평가를 위한 몬테카를로용 산란선 제거 그리드 작성에 관한 연구)

  • Yeji Kim;Hyejin Jo;Yongsu Yoon
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.1-6
    • /
    • 2024
  • In Recent years, there has been a noticeable increase in the global incidence of breast cancer, with approximately 2.3 million cases of female breast cancer reported worldwide in 2020. Numerous studies are currently underway to enhance the accuracy of breast cancer diagnosis through the development of digital mammography detectors. This study aims to create Monte Carlo simulation-based mammographic anti-scatter grids and investigate their utility in evaluating the performance of digital mammography detector. Two types of mammographic anti-scatter grids, MAM-CP and Senographe 600T HF, were created using Monte Carlo simulation software (MCNPX 2.7.0), with grid ratios of 3.7 : 1 and 5 : 1, respectively. The grid physical characteristics (sensitivity, exposure factor, contrast improvement ratio) were calculated based on the KS C IEC60627 in the simulations using two X-ray qualities, RQA-M2 (28 kVp) and MW4 (35 kVp). As the X-ray tube voltage increased from 28 kVp to 35 kVp, sensitivity and exposure factor exhibited a decreasing trend, while contrast improvement ratio demonstrated an increasing trend. With an increase in grid ratio from 3.7 : 1 to 5 : 1, all physical characteristics showed an upward trend. Our results were consistent with a previous study that conducted measurements of physical properties using a real phantom. However, the pattern of change in the contrast improvement ratio with X-ray tube voltage differed from the previous study.

Dosimetry according to the Object Thickness (피사체(被射體)두께에 따른 선량분포(線量分布))

  • Lee, Sang-Suk;Park, Sung-Ock
    • Journal of radiological science and technology
    • /
    • v.2 no.1
    • /
    • pp.85-88
    • /
    • 1979
  • When X-radiation passes through the human body; some is transmitted some is truly absorbed, and some is scattered. In diagnostic radiography, scattered radiation can reach the film if no protective measures are taken. This scattered ray increased density which not necessary for image formation. We studied about absorbtion, scattered ray and the way of get rid of scatter ray according to the x-ray tube kilovoltage and obtained results as follow; 1. Absorbtion ray increased proportion to KVP. 2. Scattered ray increased at high KVP and thick object. 3. Secondary radiation of the primary increased at high KVP and thick object. 4. Remove .ate of scattered ray decreased at thick object and increase at low KVP make use of 6:1 grid ratio

  • PDF

Error Analysis of General X-ray Examination by Using Simulation Training (시뮬레이션 교육을 통한 일반 X선 검사의 오류 분석)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.919-927
    • /
    • 2018
  • The purpose of this study was to present simulation training model for general X-ray examinations and to analyze the errors that occur during the simulation training. From 2012 to 2018, a total of 183 students (77 men and 106 women) participated. The simulated X-ray system used computed radiography (CR) system. The contents of simulation training were patient's care, X-ray examinations accuracy, images stability, etc. As a result, it were found that the patient's position setting error, the accuracy error of the X-ray beam central ray, the image receptor's size and setting error, the error of the grid use, the marking error, and the error of X-ray exposure technical factors. It is expected that improved practical general X-ray examinations training of radiographer will be needed, focusing on these errors, so that we could contribute to the health care of the people by providing precise examinations and high quality medical service.

The Experimental Study on Performance Evaluation and Use Status of Diagnostic X-ray Grid being used in Che-ju Province (4) 제주도내 진단용 X선 격자의 이용실태와 성능평가에 관한 실험적 연구)

  • Ko In ho;Kim sung hoon;Kang chang soo;Lee kyung sung
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.25 no.1
    • /
    • pp.192-200
    • /
    • 1999
  • This experiment is to examination about the use status and the performance test of x-ray grid being used to medical center, general hospital, local clinic and college, etc in che-ju province. As results of this experiment were as follows; To the use statu

  • PDF

A Study of Scattered Radiation Effect on Digital Radiography Imaging System (디지털 방사선영상 시스템에서 산란선이 영상 품질에 미치는 영향)

  • Baek, Cheol-Ha
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.71-78
    • /
    • 2017
  • Scattered radiation is inherent phenomenon of x-ray, which occurs to the subject (or patient). Therefore it cannot be avoidable but also interacts as serious noise factor because the only meaningful information on x-ray radiography is primary x-ray photons. The purpose of this study was to quantify scattered radiation for various shooting parameters and to verify the effect of anti-scatter grid. We employed beam stopper method to characterize scatter to primary ratio. To evaluate effect on the projection images calculated contrast to noise ratio of given shooting parameters. From the experiments, we identified the scattered radiation increases in thicker patient and smaller air gap. Moreover, scattered radiation degraded contrast to noise ratio of the projection images. We find out that the anti-scatter grid rejected scattered radiation effectively, however there were not fewer than 100% of scatter to primary ratio in some shooting parameters. The results demonstrate that the scattered radiation was serious problem of medical x-ray system, we confirmed that the scattered radiation was not considerable factor of dig ital radiog raphy.