• Title/Summary/Keyword: X-ray analysis

Search Result 4,839, Processing Time 0.035 seconds

Characteristics of Clay Minerals in Sihwa Area (시화지구 연약점토의 광물학적 특성)

  • 김낙경;박종식;김유신
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.773-780
    • /
    • 2003
  • The characteristics of soft clays is very important for the land development plan. This study is to investigate correlations between the engineering properties and the characteristics of clay minerals of the disturbed clay samples obtained from Sihwa area. This study included X-Ray Diffraction Analysis, X-Ray Fluorescence Spectrometer Analysis, Scanning Electron Microscopy Analysis and Energy Dispersive X-Ray Spectrometer Analysis. The correlations between the clay mineral properties and the laboratory and field testing results were investigated.

  • PDF

Study about sacral base X-ray of Barge (Barge의 천골 기저부 X-ray에 대한 연구)

  • Min, Young-Kwang
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.6 no.1
    • /
    • pp.19-26
    • /
    • 2011
  • Objectives : The purpose of this study is to research the necessity of sacral base X-ray that Barge insisted. Methods : I have done a comparative analysis in side of short leg and side of sacral inferior with sacral base X-ray and pelvis A-P Xray pictures of 42 patients with lower back pain from December 1, 2010 to March 31, 2011. Results : Even though most of the subjects in study were male, 36 people had plateau of sacral base and 29 people had symmetry in sacral base X-ray. There was no statistical significance in the side of short leg and side of sacral base inferior in Sacral base X-ray, but there was a statistical significance in pelvis A-P x-ray. 22 people had same side of short leg and side of sacral base inferior in sacral base X-ray and pelvis A-P X-ray and 14 people didn't. 29 people had same side of sacral base inferior in sacral base X-ray and pelvis A-P X-ray and 13 people didn't. Conclusions : According to the result of the study, sacral base X-ray is necessary for correct sacral base inferior analysis.

  • PDF

A Study on Three Dimensional Coordinates Analysis Using x-Ray (X-Ray 를 이용한 삼차원(三次元) 좌표해석(座標解析)에 관한 연구(硏究))

  • Yeu, Bock Mo;Park, Joon Kyu;Kim, In Sop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.89-98
    • /
    • 1987
  • X-Ray photogrammetry is the method that register and analize the anatomical or physiological information about the human body by the photography form. In this paper, using X-Ray, accuracy of three dimensional coordinates of objects which are deformed and a part of human body is analyzed. An objective of this analysis lies in improving the accuracy of three dimensional coordinates and enhancing the practical use. Through the observation, X-Ray Photogrammetry is used in practical use. And X-Ray photograph is used the reform of graphical model by the determination of the three dimensional coordinates about all sides of object.

  • PDF

A Copper Shield for the Reduction of X-γ True Coincidence Summing in Gamma-ray Spectrometry

  • Byun, Jong-In
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.137-142
    • /
    • 2018
  • Background: Gamma-ray detectors having a thin window of a material with low atomic number can increase the true coincidence summing effects for radionuclides emitting X-rays or gamma-rays. This effect can make efficiency calibration or spectrum analysis more complicated. In this study, a Cu shield was tested as an X-ray filter to neglect the true coincidence summing effect by X-rays and gamma-rays in gamma-ray spectrometry, in order to simplify gamma-ray energy spectrum analysis. Materials and Methods: A Cu shield was designed and applied to an n-type high-purity germanium detector having an $X-{\gamma}$ summing effect during efficiency calibration. This was tested using a commercial, certified mixed gamma-ray source. The feasibility of a Cu shield was evaluated by comparing efficiency calibration results with and without the shield. Results and Discussion: In this study, the thickness of a Cu shield needed to avoid true coincidence summing effects due to $X-{\gamma}$ was tested and determined to be 1 mm, considering the detection efficiency desired for higher energy. As a result, the accuracy of the detection efficiency calibration was improved by more than 13% by reducing $X-{\gamma}$ summing. Conclusion: The $X-{\gamma}$ summing effect should be considered, along with ${\gamma}-{\gamma}$ summing, when a detection efficiency calibration is implemented and appropriate shielding material can be useful for simplifying analysis of the gamma-ray energy spectra.

Study on the Improvement of Indirect Intra-Oral Dental Digital X-ray Image Sensor with Optical Coupling

  • Whang, Joo-Ho;Chung, Jin-Bum;Kim, Tae-Woo
    • Nuclear Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.514-525
    • /
    • 2001
  • Optimum characteristics of digital X-ray sensor components were analyzed to develop intra- oral dental digital X-ray image sensor using indirect method. Parametric analysis was carried out to optimize the phosphor thickness and the fiber optic plate (FOP) coupling to charge coupled device (CCD). X-ray absorption and light diffusion in the phosphor layer were analyzed by the Monte Carlo method. Real time X-ray image was obtained with prototype X- ray image sensor using general CCD camera with 1∼10 Ip/mm resolution. It has been previously shown that large resolution degradation in X-ray images was caused by miss alignment of FOP to CCD and optical adhesive selection. In this study, we reported that X-ray image quality was greatly improved by using optimized characteristics of alignment device and phosphor thickness.

  • PDF

Determination of Thin Film Thickness by EDS Analysis and its Modeling (EDS 분석과 모델링에 의한 박막두께 측정 방법에 관한 연구)

  • Yun, Jae-Jin;Lee, Won-Jong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.8
    • /
    • pp.647-653
    • /
    • 2011
  • In this study, a method to measure the thickness of thin film by EDS (energy dispersive spectroscopy) is suggested. We have developed a model which calculates the thickness of thin film from the characteristic x-ray intensity ratio of the elements in thin film and substrate by considering incident electron beam energy, x-ray generation curve, backscattering and absorption of x-ray, take-off angle of x-ray and tilt angle of the sample. We obtained the relation curve between the film thickness measured experimentally and the x-ray intensity ratio of elements. The film thicknesses calculated from the model agrees quite well with those measured experimentally. Therefore, the thin film thickness can be measured rapidly and accurately by using the model developed in this study and the x-ray intensity ratio obtained in EDS analysis.

Vertical Space Analysis for Gradient Radiating Steel-tube Radiographic Image (경사조사(傾斜照射) 강판튜브 방사선 관측영상의 수직 방향 공간분석)

  • Hwang, Jung-Won;Hwang, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.29-31
    • /
    • 2007
  • In this paper we propose an directional analytic approach in image data space for X-ray image which is detected from the X-ray projection system. Such a radiographic nondestructive testing has long been used for steel-tube inspection and weld monitoring. The welded area and thickness of steel-tube are detected from gradient radiating mechanism based on the evaluation of biased X-ray source position. The welded area is an ellipse type on low contrast X-ray image including noise. Noise originates from most of elements of the system. such as shielding CCD camera, imaging screen, X-ray source, inspected object, electronic circuits and etc.. Projection incorrectness and noise influence on imaging quality is to be represented by vertical pixels' distribution. Space analysis due to vertical direction also shows the segmental possibility between regions by visual edge evaluation.

  • PDF

The Correlations between Mineralogy and Engineering Characteristics of Soft Clay in Sihwa Area (시화지구 연약점토의 광물학적 특성과 공학적 특성의 상관관계)

  • Kim Nak-Kyung;Park Jong-Sik;Joo Yong-Sun
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.9
    • /
    • pp.155-166
    • /
    • 2004
  • The characteristics of soft clays are very important for the land development plan. This study is to investigate correlations between the engineering properties and the characteristics of clay minerals of the undisturbed clay samples obtained from Sihwa area. This study included X-Ray diffraction analysis, X-Ray fluorescence spectrometer analysis, scanning electron microscopy analysis and energy dispersive X-Ray spectrometer analysis. The correlations between the clay mineral properties and the laboratory and field testing results were investigated. The characteristics of soft clay in Sihwa area were compared with those in Yangsan and Kunsan area.

Noise Characteristic Analysis of X-Ray Fluorescence Spectrum (형광 X-선 스펙트럼의 잡음 특징 분석)

  • Lee, Jae-Hwan;Chon, Sun-Il;Yang, Sang-Hoon;Park, Dong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2298-2304
    • /
    • 2012
  • X-ray fluorescence spectrum analysis method can be applied in many areas, including concentration analysis of RoHS elements and heavy metals etc. and we can get analysis results in a relatively short time. Because X-ray fluorescence spectrum has noises and several artifacts that lowers the accuracy of the analysis. This paper analyzes the characteristics of the noise of the X-ray fluorescence spectrum to increase the accuracy of analysis. X-ray fluorescence spectrum have the characteristics of shot noise (Poisson noise), so the noise size is relatively large in the small signal portion and the noise the size is relatively small in the large part of the signal. Existing methods of analysis and to remove noises is a method for general purposes algorithm. Since these algorithm does not reflect these noise characteristics, we get distorted analysis result. We can design efficient noise remove algorithm based on the accurate noise analysis method, and we expect high accuracy results of the elemental concentration analysis result.