• 제목/요약/키워드: X-ray analysis

검색결과 4,839건 처리시간 0.047초

시화지구 연약점토의 광물학적 특성 (Characteristics of Clay Minerals in Sihwa Area)

  • 김낙경;박종식;김유신
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.773-780
    • /
    • 2003
  • The characteristics of soft clays is very important for the land development plan. This study is to investigate correlations between the engineering properties and the characteristics of clay minerals of the disturbed clay samples obtained from Sihwa area. This study included X-Ray Diffraction Analysis, X-Ray Fluorescence Spectrometer Analysis, Scanning Electron Microscopy Analysis and Energy Dispersive X-Ray Spectrometer Analysis. The correlations between the clay mineral properties and the laboratory and field testing results were investigated.

  • PDF

Barge의 천골 기저부 X-ray에 대한 연구 (Study about sacral base X-ray of Barge)

  • 민영광
    • 척추신경추나의학회지
    • /
    • 제6권1호
    • /
    • pp.19-26
    • /
    • 2011
  • Objectives : The purpose of this study is to research the necessity of sacral base X-ray that Barge insisted. Methods : I have done a comparative analysis in side of short leg and side of sacral inferior with sacral base X-ray and pelvis A-P Xray pictures of 42 patients with lower back pain from December 1, 2010 to March 31, 2011. Results : Even though most of the subjects in study were male, 36 people had plateau of sacral base and 29 people had symmetry in sacral base X-ray. There was no statistical significance in the side of short leg and side of sacral base inferior in Sacral base X-ray, but there was a statistical significance in pelvis A-P x-ray. 22 people had same side of short leg and side of sacral base inferior in sacral base X-ray and pelvis A-P X-ray and 14 people didn't. 29 people had same side of sacral base inferior in sacral base X-ray and pelvis A-P X-ray and 13 people didn't. Conclusions : According to the result of the study, sacral base X-ray is necessary for correct sacral base inferior analysis.

  • PDF

X-Ray 를 이용한 삼차원(三次元) 좌표해석(座標解析)에 관한 연구(硏究) (A Study on Three Dimensional Coordinates Analysis Using x-Ray)

  • 유복모;박준규;김인섭
    • 대한토목학회논문집
    • /
    • 제7권2호
    • /
    • pp.89-98
    • /
    • 1987
  • X-Ray 사진측량(寫眞測量)은 인체에 대한 해부학적(解剖學的) 또는 생리학적(生理學的) 자료를 사진형태로 기록하여 해석하는 방법이다. 본 연구는 X-Ray를 이용하여 모델이 되는 피사체(被寫體)에 변형(變形)을 준 각 경우와, 인체 부분을 모델로 할 경우의 3 차원 좌표에 대한 정확도를 분석하므로써, X-Ray 사진(寫眞)에 의한 3 차원 위치결정의 정확도(正確度)를 향상시키고, 실용성을 높이는데 그 목적을 두고 있다. X-Ray를 이용하여 인체부분의 실제 피사체(被寫體)를 관측(觀測)한 결과, 높은 정확도(正確度)로 실제응용을 할 수 있었으며, X-Ray 사진을 이용하여 피사체(被寫體) 모든 면에 대한 삼차원(三次元) 좌표(座標)를 결정 할 수 있었다.

  • PDF

A Copper Shield for the Reduction of X-γ True Coincidence Summing in Gamma-ray Spectrometry

  • Byun, Jong-In
    • Journal of Radiation Protection and Research
    • /
    • 제43권4호
    • /
    • pp.137-142
    • /
    • 2018
  • Background: Gamma-ray detectors having a thin window of a material with low atomic number can increase the true coincidence summing effects for radionuclides emitting X-rays or gamma-rays. This effect can make efficiency calibration or spectrum analysis more complicated. In this study, a Cu shield was tested as an X-ray filter to neglect the true coincidence summing effect by X-rays and gamma-rays in gamma-ray spectrometry, in order to simplify gamma-ray energy spectrum analysis. Materials and Methods: A Cu shield was designed and applied to an n-type high-purity germanium detector having an $X-{\gamma}$ summing effect during efficiency calibration. This was tested using a commercial, certified mixed gamma-ray source. The feasibility of a Cu shield was evaluated by comparing efficiency calibration results with and without the shield. Results and Discussion: In this study, the thickness of a Cu shield needed to avoid true coincidence summing effects due to $X-{\gamma}$ was tested and determined to be 1 mm, considering the detection efficiency desired for higher energy. As a result, the accuracy of the detection efficiency calibration was improved by more than 13% by reducing $X-{\gamma}$ summing. Conclusion: The $X-{\gamma}$ summing effect should be considered, along with ${\gamma}-{\gamma}$ summing, when a detection efficiency calibration is implemented and appropriate shielding material can be useful for simplifying analysis of the gamma-ray energy spectra.

Study on the Improvement of Indirect Intra-Oral Dental Digital X-ray Image Sensor with Optical Coupling

  • Whang, Joo-Ho;Chung, Jin-Bum;Kim, Tae-Woo
    • Nuclear Engineering and Technology
    • /
    • 제33권5호
    • /
    • pp.514-525
    • /
    • 2001
  • Optimum characteristics of digital X-ray sensor components were analyzed to develop intra- oral dental digital X-ray image sensor using indirect method. Parametric analysis was carried out to optimize the phosphor thickness and the fiber optic plate (FOP) coupling to charge coupled device (CCD). X-ray absorption and light diffusion in the phosphor layer were analyzed by the Monte Carlo method. Real time X-ray image was obtained with prototype X- ray image sensor using general CCD camera with 1∼10 Ip/mm resolution. It has been previously shown that large resolution degradation in X-ray images was caused by miss alignment of FOP to CCD and optical adhesive selection. In this study, we reported that X-ray image quality was greatly improved by using optimized characteristics of alignment device and phosphor thickness.

  • PDF

EDS 분석과 모델링에 의한 박막두께 측정 방법에 관한 연구 (Determination of Thin Film Thickness by EDS Analysis and its Modeling)

  • 윤재진;이원종
    • 한국전기전자재료학회논문지
    • /
    • 제24권8호
    • /
    • pp.647-653
    • /
    • 2011
  • In this study, a method to measure the thickness of thin film by EDS (energy dispersive spectroscopy) is suggested. We have developed a model which calculates the thickness of thin film from the characteristic x-ray intensity ratio of the elements in thin film and substrate by considering incident electron beam energy, x-ray generation curve, backscattering and absorption of x-ray, take-off angle of x-ray and tilt angle of the sample. We obtained the relation curve between the film thickness measured experimentally and the x-ray intensity ratio of elements. The film thicknesses calculated from the model agrees quite well with those measured experimentally. Therefore, the thin film thickness can be measured rapidly and accurately by using the model developed in this study and the x-ray intensity ratio obtained in EDS analysis.

경사조사(傾斜照射) 강판튜브 방사선 관측영상의 수직 방향 공간분석 (Vertical Space Analysis for Gradient Radiating Steel-tube Radiographic Image)

  • 황중원;황재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.29-31
    • /
    • 2007
  • In this paper we propose an directional analytic approach in image data space for X-ray image which is detected from the X-ray projection system. Such a radiographic nondestructive testing has long been used for steel-tube inspection and weld monitoring. The welded area and thickness of steel-tube are detected from gradient radiating mechanism based on the evaluation of biased X-ray source position. The welded area is an ellipse type on low contrast X-ray image including noise. Noise originates from most of elements of the system. such as shielding CCD camera, imaging screen, X-ray source, inspected object, electronic circuits and etc.. Projection incorrectness and noise influence on imaging quality is to be represented by vertical pixels' distribution. Space analysis due to vertical direction also shows the segmental possibility between regions by visual edge evaluation.

  • PDF

시화지구 연약점토의 광물학적 특성과 공학적 특성의 상관관계 (The Correlations between Mineralogy and Engineering Characteristics of Soft Clay in Sihwa Area)

  • 김낙경;박종식;주용선
    • 한국지반공학회논문집
    • /
    • 제20권9호
    • /
    • pp.155-166
    • /
    • 2004
  • 국내 연약지반 활용을 위한 효율적이고 경제적인 안정처리 공법의 선정과 설계 및 시공을 위해서는 대상지반의 특성을 파악하는 것이 대단히 중요하다. 본 연구는 시화지구 연약점토의 물리적, 역학적 특성과 광물학적 특성을 파악하여 연약점토의 물리적, 역학적 특성과 광물학적 특성과의 상관관계를 알아보는 데 그 목적이 있다. 본 연구에서 는 연약점토의 광물학적 특성을 파악하기 위하여 X선 형광분석, X선 회절분석, 주사전자현미경분석과 에너지분산미분석 실험을 실시하였으며 시화지구 연약지반의 시추조사결과, 실내시험 및 현장시험결과와의 상관관계를 알아보았다. 또한 시화지구 연약점토의 특성을 양산과 군산 지역 연약점토의 특성과 비교하였다.

형광 X-선 스펙트럼의 잡음 특징 분석 (Noise Characteristic Analysis of X-Ray Fluorescence Spectrum)

  • 이재환;천선일;양상훈;박동선
    • 한국산학기술학회논문지
    • /
    • 제13권5호
    • /
    • pp.2298-2304
    • /
    • 2012
  • 형광 X-선 스펙트럼을 분석 방법은 RoHS 성분 및 중금속 함량 분석 등 여러 분야에 응용이 가능하며 비교적 빠른 시간 안에 함량 분석 결과를 얻을 수 있다. 형광 X-선 스펙트럼에는 잡음 및 여러 요인이 포함되어 있어 분석 정확도를 떨어뜨린다. 본 논문에서는 여러 요인 중 잡음의 특징을 분석하여 형광 X-선 스펙트럼 분석의 정확도를 높이고자 한다. 형광 X-선 스펙트럼은 산탄잡음(푸아송 잡음)의 특징을 가지고 있으며, 따라서 작은 신호에서는 잡음의 크기가 상대적으로 크고, 큰 신호에서는 잡음의 크기가 상대적으로 작은 특징을 가지고 있다. 기존에 잡음을 분석하고 제거하는 방법 및 알고리즘은 이러한 특징을 반영하지 않은 일반적인 목적으로 사용되는 방법으로 일반적인 알고리즘을 사용하여 잡음을 제거하게 되면 왜곡된 결과를 얻게 된다. 정확한 잡음 분석을 기반으로 효율적인 잡음 제거 알고리즘을 설계할 수 있고, 또한 높은 정확도의 원소 함량 분석 결과를 기대할 수 있다.