• Title/Summary/Keyword: X-ray 시스템

Search Result 499, Processing Time 0.026 seconds

Biodiesel Production with Zinc Aluminate Catalysts in a High-Pressure-Fixed-Bed-Reactor (Zinc Aluminate 촉매를 이용한 고압연속식 고정층 반응기에서의 바이오디젤 제조)

  • Vu, Khanh Bao;Phan, Thuy Duong Nguyen;Kim, Sunwook;Shin, Eun Woo
    • Korean Chemical Engineering Research
    • /
    • v.46 no.1
    • /
    • pp.189-193
    • /
    • 2008
  • In this study, the effect of reaction conditions on the transesterification of soybean oil and methanol was investigated in a high-pressure-fixed-bed-reactor-system with zinc aluminate catalysts. Without catalysts, high-pressure-reaction at $300^{\circ}C$ and 1,200 psi brought 19% yields of methyl esters, which was caused by the approach of reaction condition to supercritical point of methanol. However, except the specific reaction condition, the yields in the reaction with no catalyst were very low below 4.5%. The zinc aluminate was prepared as catalyst by coprecipitation and characterized with $N_2$ gas adsorption/desorption and X-ray diffraction. With catalyst, the effect of the reaction parameters such as temperature, pressure, and molar ratio of reactants on biodiesel production was demonstrated. The higher temperature, pressure, and methanol molar ratio to soybean oil, the more yields of methyl esters. It was proved that among the reaction parameters, the reaction temperature be the most influential variable on methyl ester yields.

Characteristics of amorphous indium tin oxide films on PET substrate grown by Roll-to-Roll sputtering system (저온 Roll-to-Roll 스퍼터 시스템을 이용하여 PET 기판위에 성막 시킨 ITO 박막의 전기적, 광학적, 구조적 특성)

  • Cho, Sung-Woo;Bae, Jung-Hyeok;Choi, Kwang-Hyuk;Moon, Jong-Min;Jeong, Jin-A;Jeong, Soon-Wook;Kim, Han-Ki
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.380-381
    • /
    • 2007
  • This paper reports on the deposition conditions and properties of ITO films used as electrode layer in a organic light emitting diodes on a PET substrate. The deposition technique employed was specially designed roll-to-roll sputtering. The oxide was deposited at room temperature in an argon and oxygen plasma on a transparent conducting ITO layer on a PET film. The influence of deposition parameters such as DC power, working pressure and oxygen partial pressure has been investigated, in order to obtain the best compromise between a high deposition rate and adequate electro-optical properties. Electrical and optical properties of ITO films were analyzed by Hall measurement examinations with van der pauw geometry at room temperature and UV/Vis spectrometer analysis, respectively. In addition, the structural properties and surface smoothness were measured by x-ray diffraction and scaning electron microscopy, respectively. From optimized ITO films grown by roll-to-roll sputter system, good electrical$(6.44{\times}10^{-4}\;{\Omega}-cm)$ and optical(above 86 % at 550 nm) properties were obtained. Also, the ITO films exhibited amorphous structure and very flat surface beacause of low deposition temperature.

  • PDF

Preparation and Characterization of Pamidronate-loaded PLGA Wafer for the Treatment of Bone Resorption (골 재흡수 치료를 위한 파미드로네이트를 함유한 이식형 생분해성 PLGA 웨이퍼의 제조와 특성결정)

  • 유제영;김상욱;강길선;성하수;정제교
    • Polymer(Korea)
    • /
    • v.26 no.5
    • /
    • pp.680-690
    • /
    • 2002
  • Implantable biodegradable wafers were prepared with pamidronate -loaded poly (L-lactide-co-glycolide) (PLGA, 75 : 25 mole ratio by lactide to glycolide, molecular weight : 20000 and 90000 g/mole) by direct compression method for the sustained release of pamidronate to investigate the possibility for the treatment of bone resorption. Pamidronate-loaded PLGA powders were prepared by means of physical mixing and spray drying with the control of formulation factors and characterized by scanning electron microscope and X-ray diffractometer. The pamidronate-loaded PLGA powders fabricated into wafers by direct compression under the constant pressure and time at room temperature. These wafers were also observed for their structural characteristic, release pattern, and degradation pattern. The release rate of pamidronate increased with increasing their initial loading ratio as well as increasing wafer thickness. The molecular weight of PLGA affects the release pattern : the higher molecular weight of PLGA, the faster release rate. It can be explained that the higher viscosity of high molecular PLGA solution at same concentration tends to aggregate PLGA and pamidronate resulting in unstable pharmaceutical dosage form. This system had advantages in terms of simplicity in design and obviousness of drug release rate and nay be useful as an implantable dosage form for the treatment of aural cholesteatoma.

Study of the Tribological Characteristics Based on the Hardness of the Brake Disk between the Sintered Metallic Friction Material and the Heat-resisting Steel Disks (디스크 경도에 따른 소결마찰재와 내열강 디스크의 마찰·마모 특성)

  • Na, Sun Joo;Park, Hyoung Chul;Kim, Sang Ho
    • Tribology and Lubricants
    • /
    • v.31 no.2
    • /
    • pp.42-49
    • /
    • 2015
  • Because of the growing need for high-speed transport options such as trains and aircraft, there is increasing demand for technology related to high-speed trains. Among them, braking systems are important in high-speed trains in terms of reliability. Especially, the disk brake system, in use in most high-speed trains, transforms kinetic energy into thermal energy and noise. Therefore, the material properties of both the friction materials and disks are expected to influence the tribological characteristics. In this paper, the tribological characteristics depend on the hardness of the brake disks between the Cu-based sintered metallic friction material and the heat-treated heat-resisting steel disks. A lab-scale dynamometer used to perform braking tests at a variety of braking speeds using dry conditions. The test results revealed that the hardness of the disks affects the friction coefficients, friction stabilities, and wear rates. Thus, the brake system using the heat-resisting steel disk requires proper heat-treatment. These differences are considered to be caused by the change in tribological mechanisms and the generation of an oxide layer on the friction surfaces. The oxide layers on the friction surfaces are confirmed to Fe2O3 by x-ray diffraction (XRD) and scanning electron microscope-energy dispersive spectroscopy (SEM-EDS) analysis.

Characteristics of Indium Tin Oxide Films Grown on PET Substrate Grown by Using Roll-to-Roll (R2R) Sputtering System (롤투롤 스퍼터 시스템을 이용하여 PET 기판위에 성막 시킨 ITO 박막의 특성 연구)

  • Cho, Sung-Woo;Choi, Kwang-Hyuk;Bae, Jung-Hyeok;Moon, Jong-Min;Jeong, Jin-A;Jeong, Soon-Wook;Park, No-Jin;Kim, Han-Ki
    • Korean Journal of Materials Research
    • /
    • v.18 no.1
    • /
    • pp.32-37
    • /
    • 2008
  • The electrical, optical, structural and surface properties of an indium tin oxide (ITO) film grown on a flexible PET substrate using a specially designed roll-to-roll (R2R) sputtering system as a function of the DC power, $Ar/O_2$ flow ratio, and rolling speed is reported. It was observed that both the electrical and optical properties of the ITO film on the PET substrate were critically dependent on the $Ar/O_2$ flow ratio. In addition, x-ray diffraction examination results showed that the structure of the ITO film on the PET substrate was an amorphous structure regardless of the DC power and the $Ar/O_2$ flow ratio due to a low substrate temperature, which was maintained constant by a main cooling drum. Under optimized conditions, ITO film with resistivity of $6.44{\times}10^{-4}{\Omega}-cm$ and transparency of 86% were obtained, even when prepared at room temperature. Furthermore, bending test results exhibited that R2R-grown ITO film had good flexibility which would be applicable to flexible displays and solar cells.

Measurement of Breast Skin Dose According to Shield Thickness During Whole Spine Scanography Using Digital Radiography System (Digital Radiography 시스템을 사용하여 전 척추검사 시 차폐체 두께에 따른 유방피부선량 측정)

  • Nam, Soon-Kwon;Choi, Joon-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.25-30
    • /
    • 2019
  • Whole Spine Scanography (WSS) using the Digital Radiography (DR) system is an examination that requires whole body X-ray exposure, which involves more exposure to radiation for patients than other general radiographies. This can affect the occurrence of breast cancer. This research measured radiation dose when breasts were shield and not shield using the Auto Exposure Control (AEC) mode. The radiation dose without a shield was 1.540 mGy, and that using a collimator was measured 0.506 mGy. Moreover, 0.733 mGy was measured when 1 shield (0.3 mm) was used, and $0.523{\mu}Gy$ when 5 of them (1.5 mm) were used. The results showed that the radiation dose with 5 shields and the radiation dose with a collimator were similar. Moreover, 0.233 mGy was measured when 8 shields (2.4 mm) were used. The standard deviation were 0.081 when using collimator and 0.014 when 5 shields were used. Also, when 8 shields were used, it was found to be 0.002. Most patients who go under a scoliosis test are children or young people who are highly sensitive to radiation. In the research results, the case where the organs sensitive to radiation, women's breasts, were shielded showed more distinct differences compared to without shields. It is considered that using shields can provide more constant shield than using a collimator and lower the risk of breast cancer caused by exposure to radiation.

A Comparative Study on the Dose of GEANT4-DICOM to TPS for High-Energy Radiation Treatment (고 에너지 방사선치료 시 GEANT4-DICOM과 TPS간 선량비교 연구)

  • Kwak, Keun-Tak;Kim, Yang-Soo;Kwon, Hyoung-Cheol;Kim, Jung-Soo;Lee, Sun-Young
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.567-572
    • /
    • 2018
  • Radiation therapy is one of the beneficial choices in the treatment of cancer. This is a comparison of TPS(Treatment Planning System) and GEANT4-DICOM, which should be preceded by the best radiation therapy. A treatment plan for prostate cancer was established with Eclipse and the point doses 366.1 cGy, 189.1 cGy, 213.4 cGy, 127 cGy, 105.7 cGy of any five prostate, bladder, rectum, right femoral head and left femoral head were identified. GEANT4-DICOM simulation showed that the results of Eclipse and ${\pm}2%$ dose error were confirmed. The monthly X-ray output agreement management value recommended by TG-142 is ${\pm}2%$, which means that the experimental results can be meaningful. In conclusion, GEANT4-DICOM is an infinite way to obtain more extended dose information once the time constraints are overcome in the simulation.

Hydrothermal Growth and Characterization of ZnO Nanostructures on R-plane Sapphire Substrates (R-plane Sapphire 기판에 수열합성법으로 제작된 ZnO 나노구조체의 성장 및 특성)

  • Cho, Guan Sik;Kim, Min Su;Leem, Jae-Young
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.8
    • /
    • pp.605-611
    • /
    • 2012
  • ZnO nanostructures were grown on R-plane sapphire substrates with seed layers annealed at different temperatures ranging from 600 to $800^{\circ}C$. The properties of the ZnO nanostructures were investigated by scanning electron microscopy, high-resolution X-ray diffraction, UV-visible spectrophotometer, and photoluminescence. For the as-prepared seed layers, ZnO nanorods and ZnO nanosheets were observed. However, only ZnO nanorods were grown when the annealing temperature was above $700^{\circ}C$. The crystal qualities of the ZnO nanostructures were enhanced when the seed layers were annealed at $700^{\circ}C$. In addition, the full width at half maximum (FWHM) of near-band-edge emission (NBE) peak was decreased from 139 to 129 meV by increasing the annealing temperature to $700^{\circ}C$. However, the FWHM was slightly increased again by a further increase in the annealing temperature. Optical transmittance in the UV region was almost zero, while that in the visible region was gradually increased as the annealing temperature increased to $700^{\circ}C$. The optical band gap of the ZnO nanostructures was increased as the annealing temperature increased to $700^{\circ}C$. It is found that the optical properties as well as the structural properties of the rod-shaped ZnO nanostructures grown on R-plane sapphire substrates by hydrothermal method are improved when the seed layers are annealed at $700^{\circ}C$.

Evaluation on the Accuracy of Targeting Error Correction Through the Application of Target Locating System in Robotic CyberKnife (로봇 사이버나이프에서 위치인식시스템을 이용한 Targeting Error값 보정의 정확성 평가)

  • Jeong, Young-Joon;Jung, Jae-Hong;Lim, Kwang-Chae;Cho, Eun-Ju
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: The purpose is to evaluate the accuracy of correcting the targeting error through the Target Location System (TLS) for the location change error of the reference point which arises from the movement or motion of patient during the treatment using the CyberKnife. Materials and Methods: In this test, Gafchromic MD-55 film was inserted into the head and neck phantom to analyze the accuracy of the targeting, and then the 6 MV X-ray of CyberKnife (CyberKnife Robotic Radiosurgery System G4, Accuray, US) was irradiated. End to End (E2E) program was used to analyze the accuracy of targeting, which is provided by Accuray Corporation. To compute the error of the targeting, the test was carried out with the films that were irradiated 12 times by maintaining the distance within the rage of $0{\pm}0.2\;mm$ toward x, y, z from the reference point and maintaining the angle within the rage of $0{\pm}0.2^{\circ}$ toward roll, pitch, yaw, and then with the films which were irradiated 6 times by applying intentional movement. And the correlation in the average value of the reference film and the test film were analyzed through independent samples t-test. In addition, the consistency of dose distribution through gamma-index method (dose difference: 3%) was quantified, compared, and analyzed by varying the distance to agreement (DTA) to 1 mm, 1.5 mm, 2 mm, respectively. Results: E2E test result indicated that the average error of the reference film was 0.405 mm and the standard deviation was 0.069 mm. The average error of the test film was 0.413 mm with the standard deviation of 0.121 mm. The result of independent sampling t-test for both averages showed that the significant probability was P=0.836 (confidence level: 95%). Besides, by comparing the consistency of dose distribution of DTA through 1 mm, 1.5 mm, 2 mm, it was found that the average dose distribution of axial film was 95.04%, 97.56%, 98.13%, respectively in 3,314 locations of the reference film, consistent with the average dose distribution of sagittal film that was 95.47%, 97.68%, 98.47%, respectively. By comparing with the test film, it was found that the average dose distribution of axial film was 96.38%, 97.57%, 98.04%, respectively, at 3,323 locations, consistent with the average dose distribution of sagittal film which was 95.50%, 97.87%, 98.36%, respectively. Conclusion: Robotic CyberKnife traces and complements in real time the error in the location change of the reference point caused by the motion or movement of patient during the treatment and provides the accuracy with the consistency of over 95% dose distribution and the targeting error below 1 mm.

  • PDF

Truncation Artifact Reduction Using Weighted Normalization Method in Prototype R/F Chest Digital Tomosynthesis (CDT) System (프로토타입 R/F 흉부 디지털 단층영상합성장치 시스템에서 잘림 아티팩트 감소를 위한 가중 정규화 접근법에 대한 연구)

  • Son, Junyoung;Choi, Sunghoon;Lee, Donghoon;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.111-118
    • /
    • 2019
  • Chest digital tomosynthesis has become a practical imaging modality because it can solve the problem of anatomy overlapping in conventional chest radiography. However, because of both limited scan angle and finite-size detector, a portion of chest cannot be represented in some or all of the projection. These bring a discontinuity in intensity across the field of view boundaries in the reconstructed slices, which we refer to as the truncation artifacts. The purpose of this study was to reduce truncation artifacts using a weighted normalization approach and to investigate the performance of this approach for our prototype chest digital tomosynthesis system. The system source-to-image distance was 1100 mm, and the center of rotation of X-ray source was located on 100 mm above the detector surface. After obtaining 41 projection views with ${\pm}20^{\circ}$ degrees, tomosynthesis slices were reconstructed with the filtered back projection algorithm. For quantitative evaluation, peak signal to noise ratio and structure similarity index values were evaluated after reconstructing reference image using simulation, and mean value of specific direction values was evaluated using real data. Simulation results showed that the peak signal to noise ratio and structure similarity index was improved respectively. In the case of the experimental results showed that the effect of artifact in the mean value of specific direction of the reconstructed image was reduced. In conclusion, the weighted normalization method improves the quality of image by reducing truncation artifacts. These results suggested that weighted normalization method could improve the image quality of chest digital tomosynthesis.