• Title/Summary/Keyword: X-ray 시스템

Search Result 499, Processing Time 0.025 seconds

New Photochemistry of UV-Absorbing Chemicals in Phase-Controlled Polymer Microspheres (상구조가 조절된 고분자 미립구에서 자외선 흡수제의 거동에 대한 연구)

  • Lee Jong-Suk;Kim Jin-Woong;Kim Junoh;Han Sang-Hoon;Chang Ih-Seop
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.3 s.47
    • /
    • pp.361-367
    • /
    • 2004
  • In this study, a different UV (ultra-violet) ray absorption system is presented in which butyl methoxydiben-zoylmethane (BMDM, a model UV-A absorbent, 320$\~$400 nm) is stabilized in phase-controlled poly(methyl methacrylate) (PMMA) microspheres. The photochemistry of BMDM in the microspheres was investigated considering its phase characteristics therein. The analysis of a differential scanning calorimeter and X-ray diffractometer showed that the BMDM in the microspheres was present with a non-crystalline state. The phase control of BMDM in the polymer microsphere has an excellent ability to protect UV-A with maintaining its photo- and thermal stability. The results obtained in this study illustrate well that the phase control of the UV absorbents in the polymer microspheres is another key factor that de-termines its photochemistry and photostability in the final formulations.

Design a Four Layer Depth-Encoding Detector Using Quasi-Block Scintillator for High Resolution and Sensitivity (고분해능 및 고민감도를 위한 준 블록 섬광체를 사용한 네 층의 반응 깊이 측정 검출기 설계)

  • Seung-Jae Lee;Byungdu Jo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.65-71
    • /
    • 2024
  • To achieve high resolution and sensitivity of positron emission tomography (PET) for small animals, the detector is constructed using very thin and long scintillation pixels. Due to the structure of these scintillation pixels, spatial resolution deterioration occurs outside the system's field of view. To solve this problem, we designed a detector that could improve spatial resolution by measuring the interaction depth and improve sensitivity by using a quasi-block scintillator. A quasi-block scintillator size of 12.6 mm x 12.6 mm x 3 mm was arranged in four layers, and optical sensors were placed on all sides to collect light generated by the interaction between gamma rays and the scintillator. DETECT2000 simulation was performed to evaluate the performance of the designed detector. Flood images were acquired by generating gamma-ray events at 1 mm intervals from 1.3 mm to 11.3 mm within the scintillator of each layer. The spatial resolution and peak-to-peak distance for each location were measured in an 11 x 11 array of flood images. The average measured spatial resolution was 0.25 mm, and the average distance between peaks was 1.0 mm. Through this, it was confirmed that all locations were separated from each other. In addition, because the light signals of all layers were measured separately from each other, the layer of the scintillator that interacted with the gamma rays could be completely separated. When the designed detector is used as a detector in a PET system for small animals, it is considered that excellent spatial resolution and sensitivity can be achieved and image quality can be improved.

Study on Exchange Coupling in Bilayer Systems using Co-Based Multilayer Thin Films (Co계 다층박막을 이용한 이중막에서 Direct Overwriting을 위한 교환결합 연구)

  • 문기석;최석봉;신성철
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.1
    • /
    • pp.15-20
    • /
    • 1996
  • Co/Pd와 Co/Pd 다층박막으로 구성된 이중막 시스템에서 direct overwriting을 구현하는데 필수적인 교환결합 (exchange coupling)에 대하여 연구하였다. Co/Pd 및 Co/Pd 다층박막을 수직자성을 가지도록 하기 위하여 Co층의 두께를 4- .angs. 이하로 하여 전자빔 증착법으로 제작한 후 x-ray 회절 실험으로 구조 분석을 하였고, Kerr spectrometer, VSM을 사용하여 자기 및 자기광학적 성질을 조사하였다. 기억막과 기준막으로 구성된 이중막에서는 exchange coupling이 커서 자화반전이 두 박막에서 동시에 일어나며, 두 박막사이에 적당한 두께의 비자성 사이막(non-magnetic spacer)이 존재하는 경우에는 두 박막사이의 교환결합의 크기가 줄어들어서 두 박막의 자화반전이 분리되어 계단식 자화곡선이 생겼다. 또 비자성 사이막이 두꺼우면 두 박막사이의 교환결합이 사라짐이 관찰 되었다. 두 박막사이의 교환결합은 자구 기록 실험을 통해서도 그 존재를 확인할 수 있었다.

  • PDF

Development of real-time nanoscale contaminant particle characteristics diagnosis system in vacuum condition (진공공간 내 나노급 오염입자의 실시간 진단시스템 개발)

  • Kang, Sang-Woo;Kim, Taesung
    • Vacuum Magazine
    • /
    • v.2 no.3
    • /
    • pp.11-15
    • /
    • 2015
  • Particle characteristics diagnosis system (PCDS) was developed to measure submicron particle characteristics by modulation of particle beam mass spectrometry (PBMS) with scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS). It is possible to measure the particle size distribution in real-time, and the shape, composition can be measured in sequence keeping vacuum condition. Apparatus was calibrated by measuring the size classified NaCl particle which generated at atmospheric pressure. After the calibration, particles were sampled from the exhaust line of plasma enhanced chemical vapor deposition (PECVD) process and measured. Result confirms that PCDS is capable for analyzing particles in vacuum condition.

Manufacturing of SPL system having a large scanning area (대면적 SPL(Scanning Probe Lithography) 시스템 제작)

  • Yoon, Sang-Joon;Kim, Won-Hyo;Seong, Woo-Kyeong;Park, Young-Geun;Hwang, Kyu-Ho;Chung, Kwan-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.699-702
    • /
    • 2004
  • Next generation lithography technologies, such as EBL(Electron Beam Lithography), X-ray lithography, SPL(Scanning Probe Lithography), have been studied widely for getting over line width limitation of photolithography. Among the next generation lithography technologies, SPL has been highlighted because of its high resolution advantage. But is also has problem which are slow processing time and sample size limitation. The purpose of this study is complement of present SPL system. Brand new SPL system was made. SPL test was performed with the system in ultra thin PMMA(polymethlymethacrylate) film.

  • PDF

Development and Performance Test of In-situ Particle Monitoring System using Ion-counter in Vacuum Environments (진공 환경내 실시간 입자 모니터링 시스템의 개발 및 성능평가)

  • Ahn Kang-Ho;Kim Yong-Min;Kwon Yong-Taek
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.1 s.14
    • /
    • pp.45-49
    • /
    • 2006
  • In this paper, a new method that monitors the quantity of particles using ion-counter in vacuum environment is introduced. In-situ particle monitoring (ISPM) system is composed by Gerdien type ion-counter (house-made), DC power supply and electrometer. The ion-counter applied by positive voltage detects only positive charged particles. Therefore the particles to be detected should be in known charge state for further data analysis. ion-counter is installed at the exhaust line of process equipment where the pressure loss is structurally low. ISPM system performance has been verified with SMPS (Scanning Mobility Particle Sizer) system. The correlation coefficient is above 0.98 at the particle size range of $20{\sim}300nm$ in diameter with identified charge distribution under $0.1{\sim}10.0$ Torr.

  • PDF

An Application of Single Screen-Film System on General Radiography (일반(一般)X선촬영(線撮影)에 있어서 편면(片面)시스템의 응용(應用))

  • Park, Myeong-Hoan;Cho, Joon-Suk;Song, Jae-Kwan;Huh, Joon;Yoo, Jang-Soo
    • Journal of radiological science and technology
    • /
    • v.13 no.2
    • /
    • pp.15-20
    • /
    • 1990
  • In clinical fields, single screen-film system will be generalized according to high speed and high image qualify of intensifying screen film system in future. In single screen-film system, for imaging the best image, we must choice good film according to speed and gredient. Double screen-film system will be replaced single screen film system in general radiography. Author has thought that single screen film system will be developed new diagnosis area according to X-Ray films.

  • PDF

Power Supply and Control System for Injector of Ion Accelerator (이온 가속기의 인젝터 전원 장치 및 제어 시스템)

  • Im, Geun-Hui;Nikiforov, S.A.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.544-549
    • /
    • 1997
  • Injector of high voltage or linear ion accelerator is intended to generate, extract and form beam of certain species with required parameters at the entrance of accelerating structure or, for low energy case, directly in the processing chamber (end station). Injector is the main part defining the ion accelerator performance and reliability. Its power supply and control system (PSCS) features are conditioned by placing the injector equipment at high voltage potential and by complexity of the plasma-beam load. The injector's PSCS should provide: - Transmission of electric power onto high voltage (h/v) terminal; - Obtaining of required output characteristics for injector equipment operation; - Transmission of the operational data and start/stop signals from h/v terminal to control cabinet; - Rremote control of injector; - Withstanding the high voltage breakdowns and X-ray radiation; - Compatibility with other equipment. The paper is concerned with analysis of injectors' PSCS structure and description of the system developed for 50 keV, 20 mA heavy ion injector.

  • PDF

A Design of Block Cipher Algorithm for PACS (PACS를 위한 블록 암호 알고리즘의 설계)

  • Choung, Hye-Myoung;Jun, Moon-Seog
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2001.04b
    • /
    • pp.1173-1176
    • /
    • 2001
  • 정보통신의 발달로 인하여 의료분야에서도 컴퓨터 기반 환자기록이 보편화되었다. 이러한 의료정보에는 가족 병력 기록, 과거 병력 기록, 정신 질환 기록 등 개인의 텍스트 정보뿐만 아니라 X-ray 등과 같은 영상 정보들이 의료기관간의 내 외부로 이동되고 있다. 이러한 정보들은 네트워크 환경 하에서 자연히 노출될 수 있는 보안상의 문제가 대두되고 있다. 이를 위하여 기존의 의료 정보 시스템과 잘 호환되고, 안전하고, 효율적인 보안 장치가 필요한데 이러한 장치 중의 하나가 견고한 암호 알고리즘의 구축이다. 이 논문에서는 현재 PACS의 표준 프로토콜인 DICOM의 데이터 구조와 같은 크기의 블록으로 나누어 암호화는 알고리즘을 제안한다.

  • PDF

Cargo Inspection System Design and Boundary-Scan Test (화물 검색시스템 구현 및 Boundary_Scan Test)

  • Kim, Bong-Su;Kim, In-Su;Yoo, Sun-Won;Kim, Sung-Won;Lee, Sun-Wha;Yi, Yun;Han, Bum-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.197-200
    • /
    • 2002
  • We newly developed the procedures of X-ray Cargo inspection system with acquisition of multi-channel data, analog to digital converter and post logic circuit which is controlled by the FPGA. The IEEE1149.1 standard defines a four-wire serial interface(a fifth wire is optional)to access complex integrated circuits(ICs) such as PLD. This paper describes that Boundary_Scan test method applied to our home made cargo inspection system.

  • PDF