• Title/Summary/Keyword: X-ray 시스템

Search Result 499, Processing Time 0.03 seconds

Experimental Study on Deformation and Failure Behavior of Limestones under Dynamic Loadings (동적하중 하에서 석회암의 변형 및 파괴거동에 관한 실험적 연구)

  • Kang, Myoung-Soo;Kang, Hyeong-Min;Kim, Seung-Kon;Cheon, Dae-Sung;Kaneko, Katsuhiko;Cho, Sang-Ho
    • Tunnel and Underground Space
    • /
    • v.22 no.5
    • /
    • pp.339-345
    • /
    • 2012
  • Information on the deformation behavior and fracture strength of rocks subjected to dynamic loadings is important to stability analyses of underground openings underground vibration due to rock blasts, earthquakes and rock bursts. In this study, Split Hopkinson Pressure Bar (SHPB) system was applied to estimate dynamic compressive and tensile fracture strengths of limestone and also examine deformation behavior of limestones under dynamic loadings. A micro-focus X-ray CT scanner was used to observe non-destructively inside the impacted limestone specimens. From the dynamic tests, it was revealed that the limestone have over 140MPa dynamic compressive strength and the strain-rate dependency of the strength. Dynamic Brazilian tensile strength of the limestone exceeds 21MPa and shows over 3 times static Brazilian tensile strength.

이온 에너지 분석을 통한 저손상 그래핀 클리닝 연구

  • Kim, Gi-Seok;Min, Gyeong-Seok;Yeom, Geun-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.218.2-218.2
    • /
    • 2014
  • 그래핀은 높은 전기 전도도와 열전도도, 기계적 강도를 가지고 있고 동시에 높은 전자이동도($200,000cm^2{\cdot}V{\cdot}^1{\cdot}s{\cdot}^1$) 특성을 갖는 물질로써 차세대 소재로 각광받고 있다. 하지만 그래핀을 소자에 응용하기 위해서는 전사공정과 lithography 공정 과정에서 발생되는 PMMA(Poly methyl methacrylate) residue를 완벽하게 제거해야 하는 문제점이 있다. 특히, lithography 공정 중 완벽하게 PMMA residue 가 제거되지 않고 잔류해 있을 경우에 소자의 life time, performance에 악영향을 준다는 보고가 있다. 이와같은 문제를 해결하기 위해 화학적 cleaning, 열처리를 통한 cleaning, 전류 인가에 의한 cleaning과 같은 방법들을 이용하여 그래핀의 PMMA residue를 제거하는 공정들이 보고되고 있지만, 화학적 cleaning 방법의 경우 chloroform 이라는 독성물질 사용으로 인해 산업적으로 응용이 어렵고, 열처리 방법은 전극 등의 금속이 $200^{\circ}C$ 이상의 높은 온도에서 장시간 노출될 경우 쉽게 손상을 입으며, 전류 인가에 의한 cleaning 방법은 국부적으로만 효과를 볼 수 있기 때문에 lithography 공정 후 PMMA residue를 효과적으로 제거하기에는 한계를 보이고 있다. 본 연구에서는 Ar을 이용하는 Ion beam 시스템을 통해 beam energy를 제어함으로써 PMMA residue를 효과적으로 제거하는 연구를 진행하였다. 최적화된 플라즈마 발생 조건을 찾기 위해 QMS(Quadrupole Mass Spectrometer)를 이용하여 입사하는 ion energy와 flux 양을 컨트롤 하였고, 250 W에서 최적화된 ion energy distribution 영역이 존재한다는 것을 확인할 수 있었다. 또한, 25 Gauss 정도의 electro-magnetic field를 이용하여 Ar의 ion energy를 10 eV 이하로 낮추어 damage를 최소화함으로써 효과적으로 그래핀을 cleaning 할 수 있었다. Cleaning과정에서 ion bombardment에 의해 발생한 damage는 $250^{\circ}C$에서 6시간 동안 annealing 공정을 거치면서 회복되는 것을 Raman spectroscopy의 D peak ($1335cm{\cdot}^1$) / G peak ($1572cm{\cdot}^1$) ratio 로 확인할 수 있었고, PMMA residue의 cleaning 여부는 G peak ($1580cm{\cdot}^1$)의 blue shift와 2D peak ($2670cm{\cdot}^1$)의 red shift를 통해 확인하였다. 그리고 AFM (Atomic Force Microscopy)을 이용하여 cleaning 공정과정에서 RMS roughness가 4.99 nm에서 2.01 nm로 감소하는 것을 관찰하였다. 마지막으로, PMMA residue의 cleaning 정도를 정량적으로 분석하기 위해 XPS (X-ray Photoelectron Spectroscopy)를 이용하여 sp2 C-C bonding이 74.96%에서 87.66%로 증가함을 확인을 할 수 있었다.

  • PDF

Surface Characteristics of Titanium/Hydroxyapatite Double Layered Coating on Orthopedic PEEK by Magnetron Sputtering System (마그네트론 스퍼터링 시스템을 이용한 정형외과용 PEEK의 타이타늄/하이드록시아파타이트 이중 코팅층의 표면 특성 분석)

  • Kang, Kwan-Su;Jung, Tae-Gon;Yang, Jae-Woong;Woo, Su-Heon;Park, Tea-Hyun;Jeong, Yong-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.3
    • /
    • pp.164-171
    • /
    • 2018
  • In this study, we have fabricated pure titanium (Ti)/hydroxyapatite (HA) double layer coating on medical grade PEEK from magnetron sputtering system, an investigation was performed whether the surface can be had more improve bio-active for orthopedi/dental applications than that of non-coated one. Pure Ti and HA coating layer were obtained by a radio-frequency and direct current power magnetron sputtering system. The microstructures surface, mechanical properties and wettability of the pure Ti/HA double layer deposited on the PEEK were analyzed by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), nano-indentation, and contact angle test. According to the EDS and XRD results, the composition and crystal structure of pure Ti and HA coated surface were verified. The elastic modulus and hardness value were increased by pure Ti and HA coating, and the pure Ti/HA double layer coating surface has the highest value. The contact angle showed higher value for pure Ti/HA double layered coating specimens than that of non-coated (PEEK) surface.

Salt and Pepper Noise Removal Algorithm based on Euclidean Distance Weight (유클리드 거리 가중치를 기반한 Salt and Pepper 잡음 제거 알고리즘)

  • Chung, Young-Su;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.11
    • /
    • pp.1637-1643
    • /
    • 2022
  • In recent years, the demand for image-processing technology in digital marketing has increased due to the expansion and diversification of the digital market, such as video, security, and machine intelligence. Noise-processing is essential for image-correction and reconstruction, especially in the case of sensitive noises, such as in CT, MRI, X-ray, and scanners. The two main salt and pepper noises have been actively studied, but the details and edges are still unsatisfactory and tend to blur when there is a lot of noise. Therefore, this paper proposes an algorithm that applies a weight-based Euclidean distance equation to the partial mask and uses only the non-noisy pixels that are the most similar to the original as effective pixels. The proposed algorithm determines the type of filter based on the state of the internal pixels of the designed partial mask and the degree of mask deterioration, which results in superior noise cancellation even in highly damaged environments.

Evaluation of Approximate Exposure to Low-dose Ionizing Radiation from Medical Images using a Computed Radiography (CR) System (전산화 방사선촬영(CR) 시스템을 이용한 근사적 의료 피폭 선량 평가)

  • Yu, Minsun;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.455-464
    • /
    • 2012
  • This study suggested evaluation of approximately exposure to low-dose ionization radiation from medical images using a computed radiography (CR) system in standard X-ray examination and experimental model can compare diagnostic reference level (DRL) will suggest on optimization condition of guard about medical radiation of low dose space. Entrance surface dose (ESD) cross-measuring by standard dosimeter and optically stimulated luminescence dosimeters (OSLDs) in experiment condition about tube voltage and current of X-ray generator. Also, Hounsfield unit (HU) scale measured about each experiment condition in CR system and after character relationship table and graph tabulate about ESD and HU scale, approximately radiation dose about head, neck, thoracic, abdomen, and pelvis draw a measurement. In result measuring head, neck, thoracic, abdomen, and pelvis, average of ESD is 2.10, 2.01, 1.13, 2.97, and 1.95 mGy, respectively. HU scale is $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, and $2,318{\pm}4.64$, respectively, in CR image. At this moment, using characteristic relationship table and graph, ESD measured approximately 2.16, 2.06, 1.19, 3.05, and 2.07 mGy, respectively. Average error of measuring value and ESD measured approximately smaller than 3%, this have credibility cover all the bases radiology area of measurement 5%. In its final analysis, this study suggest new experimental model approximately can assess radiation dose of patient in standard X-ray examination and can apply to CR examination, digital radiography and even film-cassette system.

The Emission and Characteristics Measurement of Electron Beam and Basis Construction for Education Usage (전자빔 인출 및 빔 계측과 교육 활용을 위한 기반구축)

  • Lee, Dong-Hoon
    • Journal of IKEEE
    • /
    • v.11 no.4
    • /
    • pp.257-264
    • /
    • 2007
  • The MM22 microtron has used as a cancer therapy machine from Nov. 1986 to Feb. 2006. This machine was moved and installed to a radiation research center to use as an education and research tool from treatment machine because of aging of MM22 microtron. In this paper, for extracting the electron beam from microtron, operation principle of the microtron, system characteristics of each module, and pulse structures were reviewed. The beam extraction and measurement were performed after measuring pulses of each major module and extraction trials in the beam line. After finishing the movement of MM22 microtron, the 30mA target current in the case of 10 MV X-ray beam was extracted and the beam flatness of radiation distribution was acquired within 3% error ratio after 100 MU was irradiated on X-omatV Film at SSD 100 cm and field size $10{\times}10cm^2$. As a result, the microtron movement and new installation was performed with success.

  • PDF

Evaluation of Dose Distribution of 6 MV X-ray using Optical Dosimetry (광 도시메트리시스템을 이용한 치료용 6 MV X선 선량분포 평가)

  • Kim, Sunghwan
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.925-932
    • /
    • 2019
  • In this paper, we developed optical dosimetry system with a plastic scintillator, a commercial 50 mm, f1.8 lens, and a commercial high-sensitivity CMOS (complementary metal-oxide semiconductor) camera. And, the correction processors of vignetting, geometrical distortion and scaling were established. Using the developed system, we can measured a percent depth dose, a beam profile and a dose linearity for 6 MV medical LINAC (Linear Accelerator). As results, the optically measured percent depth dose was well matched with the measured percent depth dose by ion-chamber within 2% tolerance. And the determined flatness was 2.8%. We concluded that the optical dosimetry system was sufficient for application of absorbed dose monitoring during radiation therapy.

선형 대향 타겟 스퍼터 시스템을 이용하여 성막한 Ti-doped $In_2O_3$ 박막의 전기적, 광학적, 구조적 특성 연구

  • Lee, Ju-Hyeon;Sin, Hyeon-Su;Kim, Han-Gi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.325-325
    • /
    • 2013
  • 본 연구에서는 선형 대향 타겟 스퍼터(Linear Facing Target Sputtering: LFTS) 시스템을 이용하여 성막한 Ti-doped In2O3 (TIO) 투명 전극의 전기적, 광학적 특성을 연구하였다. LFTS 시스템을 이용하여 유리기판 위에 TIO 박막을 증착시킬 때, 타겟과 기판 사이의 거리(Target-to-Substrate Distance)를 30 mm, 타겟과 타겟 사이의 거리(Target-to-Target Distance)를 65 mm, Ar/$O_2$ 가스의 비율 100:1로 각각 고정한 후, TIO 타겟에 인가되는 DC 파워와 공정압력을 변수로 TIO 박막을 하였다. LFTS 공정을 이용한 TIO 투명전극의 성막 공정 중 DC파워와 공정압력 변화에 따른 구조적, 표면적 특성 변화는 field-effect scanning electron microscopy (FE-SEM) 과 x-ray diffractometry (XRD) 분석을 통해 관찰되었다. 이렇게 증착된 200 nm 두께의 TIO 투명전극은 급속열처리 시스템으로 700도에서 후 열처리를 진행하였으며 상온에서 217.5 ohm/sq의 면저항을 나타내는 TIO박막이 열처리후 35 ohm/sq로 면저항이 급격히 감소됨을 확인하였다. 뿐만 아니라 열처리후 가시광선 영역 (400~800 nm)에서의 TIO 박막의 평균 투과율이 81.02%에서 83.4%로 향상됨을 UV/visible spectrometry 분석을 통해 확인하였다. 본 연구에서는 다양한 분석을 통해 TIO 박막의 특성과 ITO와 구별되는 다양한 장점을 소개한다.

  • PDF

Animal Diagnosis System Using Wireless Digital Stethoscope (무선 디지털청진기를 이용한 동물 진단시스템)

  • Park, Kee-Young;Hong, Soo-Mi;Lee, Jong-Ha;Park, Jin-Ho;Jung, Eui-Bung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.9
    • /
    • pp.722-727
    • /
    • 2013
  • Medical treatment for animals is very difficult as the opinions of pets' masters take priority over treatment regardless of the seriousness of pets' disease or the needs of medical treatment. In case that a pet has heart disease, especially, it is difficult to get the direct answer from the pet's master on the decision or confirmation of treatment. For those reasons, it is almost impossible to predict and treat the pet before an emergency like the heart failure or an unexpected death happens. Using stethoscope can be the first diagnosis method to check the heart or any kinds of disease inside the body. High-tech equipments like CT, X-ray or Ultrasound can be used, but they can only be used as a second choice of diagnosis method since it requires professional skills and its high price. That's why stethoscope is still the best diagnostic tool when one makes the first diagnosis. In this study, we give a detailed account of digital diagnosis system in which veterinarians can analyze the sound from stethoscope without bringing it to their ears and make a diagnosis wherever they are. And we suggest a new concept of diagnosis system surrounding, which shows the relativeness of disease through Level Crossing Rate(LCR) and energy level from the stethoscope sound made in this system.

Development of an Automatic Seed Marker Registration Algorithm Using CT and kV X-ray Images (CT 영상 및 kV X선 영상을 이용한 자동 표지 맞춤 알고리듬 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.54-61
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The purpose of this study is to develop a practical method for determining accurate marker positions for prostate cancer radiotherapy using CT images and kV x-ray images obtained from the use of the on- board imager (OBI). $\underline{Materials\;and\;Methods}$: Three gold seed markers were implanted into the reference position inside a prostate gland by a urologist. Multiple digital image processing techniques were used to determine seed marker position and the center-of-mass (COM) technique was employed to determine a representative reference seed marker position. A setup discrepancy can be estimated by comparing a computed $COM_{OBI}$ with the reference $COM_{CT}$. A proposed algorithm was applied to a seed phantom and to four prostate cancer patients with seed implants treated in our clinic. $\underline{Results}$: In the phantom study, the calculated $COM_{CT}$ and $COM_{OBI}$ agreed with $COM_{actual}$ within a millimeter. The algorithm also could localize each seed marker correctly and calculated $COM_{CT}$ and $COM_{OBI}$ for all CT and kV x-ray image sets, respectively. Discrepancies of setup errors between 2D-2D matching results using the OBI application and results using the proposed algorithm were less than one millimeter for each axis. The setup error of each patient was in the range of $0.1{\pm}2.7{\sim}1.8{\pm}6.6\;mm$ in the AP direction, $0.8{\pm}1.6{\sim}2.0{\pm}2.7\;mm$ in the SI direction and $-0.9{\pm}1.5{\sim}2.8{\pm}3.0\;mm$ in the lateral direction, even though the setup error was quite patient dependent. $\underline{Conclusion}$: As it took less than 10 seconds to evaluate a setup discrepancy, it can be helpful to reduce the setup correction time while minimizing subjective factors that may be user dependent. However, the on-line correction process should be integrated into the treatment machine control system for a more reliable procedure.