DOI QR코드

DOI QR Code

Surface Characteristics of Titanium/Hydroxyapatite Double Layered Coating on Orthopedic PEEK by Magnetron Sputtering System

마그네트론 스퍼터링 시스템을 이용한 정형외과용 PEEK의 타이타늄/하이드록시아파타이트 이중 코팅층의 표면 특성 분석

  • Kang, Kwan-Su (Medical Device Development Center, Osong Medical Innovation Foundation) ;
  • Jung, Tae-Gon (Medical Device Development Center, Osong Medical Innovation Foundation) ;
  • Yang, Jae-Woong (Medical Device Development Center, Osong Medical Innovation Foundation) ;
  • Woo, Su-Heon (R&D Center, Medyseey Co.) ;
  • Park, Tea-Hyun (R&D Center, Medyseey Co.) ;
  • Jeong, Yong-Hoon (Medical Device Development Center, Osong Medical Innovation Foundation)
  • 강관수 (오송첨단의료산업진흥재단 첨단의료기기개발지원센터) ;
  • 정태곤 (오송첨단의료산업진흥재단 첨단의료기기개발지원센터) ;
  • 양재웅 (오송첨단의료산업진흥재단 첨단의료기기개발지원센터) ;
  • 우수헌 ((주)메디쎄이 기술연구소) ;
  • 박태현 ((주)메디쎄이 기술연구소) ;
  • 정용훈 (오송첨단의료산업진흥재단 첨단의료기기개발지원센터)
  • Received : 2018.06.25
  • Accepted : 2018.06.29
  • Published : 2018.06.30

Abstract

In this study, we have fabricated pure titanium (Ti)/hydroxyapatite (HA) double layer coating on medical grade PEEK from magnetron sputtering system, an investigation was performed whether the surface can be had more improve bio-active for orthopedi/dental applications than that of non-coated one. Pure Ti and HA coating layer were obtained by a radio-frequency and direct current power magnetron sputtering system. The microstructures surface, mechanical properties and wettability of the pure Ti/HA double layer deposited on the PEEK were analyzed by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), nano-indentation, and contact angle test. According to the EDS and XRD results, the composition and crystal structure of pure Ti and HA coated surface were verified. The elastic modulus and hardness value were increased by pure Ti and HA coating, and the pure Ti/HA double layer coating surface has the highest value. The contact angle showed higher value for pure Ti/HA double layered coating specimens than that of non-coated (PEEK) surface.

Keywords

References

  1. Ma R, Tang T, Current Strategies to Improve the Bioactivity of PEEK, Int. J. Mol. Sci., 15 (2014) 5426-5445. https://doi.org/10.3390/ijms15045426
  2. A. Godara, D. Raabe, S. Green, The influence of sterilization processes on the micromechanical properties of carbon fiber-reinforced PEEK composites for bone implant applications, Acta Biomater., 3 (2007) 209-220. https://doi.org/10.1016/j.actbio.2006.11.005
  3. A. Katzer, H. Marquardt, J. Westendorf, Wening JV, G. von Foerster, Polyetheretherketone-Cytotoxicity and mutagenicity in vitro, Biomaterials, 23 (2002) 1749-1759. https://doi.org/10.1016/S0142-9612(01)00300-3
  4. Y. Zheng, C. Xiong, S. Zhang, X. Li, L. Zhang, Bone-like apatite coating on functionalized poly(etheretherketone) surface via tailored silanization layers technique, 55 (2015) 512-523. https://doi.org/10.1016/j.msec.2015.05.070
  5. X. Wu, X. Liu, J. Wei, J. Ma, F. Deng, S. Wei, Nano-TiO2/PEEK bioactive composite as a bone substitute material: in vitro and in vivo studies, Int. J. Nanomedicine, 7 (2012) 1215-1225.
  6. Baştan, F. E., Rehman, M. A. U., Avcu, Y. Y., Avcu, E., Üstel, F., & Boccaccini, A. R., Electrophoretic co-deposition of PEEKhydroxyapatite composite coatings for biomedical applications, Colloids and Surfaces B: Biointerfaces, 169 (2018) 176-182. https://doi.org/10.1016/j.colsurfb.2018.05.005
  7. Y. H. Jeong, Y. M. Ko, H. C. Cheol, Electrochemical Properties of Ti-30Ta-(3-15)Nb Alloys Coated by HA/Ti Compound Layer, J/ Kor. Inst. Surf. Eng., 41 (2008) 57-62. https://doi.org/10.5695/JKISE.2008.41.2.057
  8. "Standard Specification for Polyetheretherketone (PEEK) Polymers for Surgical Implant Applications" ASTM F2026-17.
  9. "Biological evaluation of medical devices -- Part 1: Evaluation and testing within a risk management process" ISO 10993-1:2009.
  10. J. U. Kim, Y. H. Jeong, H. C. Choe, Measurement of oxide thin film dissolution rate on the HA?coated Ti alloy by scanning electron microscopy and impedance spectroscopy. Surface and Interface Analysis, 44 (2012) 1468-1472. https://doi.org/10.1002/sia.4977
  11. V. Kyriazis, M. Tzaphlidou, Skeletal calcium/phosphorus ratio measuring techniques and results. I. Microscopy and microtomography, Scientific World Journal, 4 (2014) 1027-1034.
  12. Joint Committee on Powder Diffraction Standard (JCPDS) and International Center for Diffraction Data (ICDD, 44-1294)
  13. H. J. Kim, Y. H. Jeong, H. C. Choe, W. A. Brantley, Hydroxyapatite formation on biomedical Ti-Ta-Zr alloys by magnetron sputtering and electrochemical deposition, Thin Solid Films, 572 (2014) 119-125. https://doi.org/10.1016/j.tsf.2014.07.058
  14. J. G. C. Wolke, K. De Groot, J. A. Jansen, In vivo dissolution behavior of various RF magnetron sputtered Ca?P coatings. J. Biomed. Mater. Res., 39 (1998) 524-530. https://doi.org/10.1002/(SICI)1097-4636(19980315)39:4<524::AID-JBM3>3.0.CO;2-L
  15. H. Isaksson, S. Nagao, M. MaLkiewicz, P. Julkunen, R. Nowak, J. S. Jurvelin, Precision of nanoindentation protocols for measurement of viscoelasticity in cortical and trabecular bone. Journal of biomechanics, 43 (2010) 2410-2417. https://doi.org/10.1016/j.jbiomech.2010.04.017
  16. K. Das, S. Bose, A. Bandyopadhyay, TiO2 nanotubes on Ti: Influence of nanoscale morphology on bone cell-materials interaction, J. Biomed. Mater. Res. A, 90 (2009) 225-237.
  17. B. G. Zhang, D. E. Myers, G. G. Wallace, M. Brandt, P. F. Choong, Bioactive coatings for orthopaedic implants-recent trends in development of implant coatings. International journal of molecular sciences, Int. J. Mol. Sci., 15, (2014) 11878-11921. https://doi.org/10.3390/ijms150711878