• Title/Summary/Keyword: X-ray 시스템

Search Result 500, Processing Time 0.024 seconds

The development of product inspection X-ray DR image processing system using intensifying screen (형광지를 이용한 물품검사 X-선 DR 영상처리 시스템 개발)

  • Park, Mun-kyu;Moon, Ha-jung;Lee, Dong-hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.7
    • /
    • pp.1737-1742
    • /
    • 2015
  • In the industrial field for product inspection needs not only on the surface of the product but also the internal components defect inspection. Generally, optical inspection is mainly used for item inspection from production process. However, this is only to check defect of surface it is difficult to perform inspection of goods internal. To overcome these limitations, Instead of optical device by using the portable X- ray DR image acquisition device system developed to obtain an image in real time at the same time and determine product defects. After obtaining the X- ray image, the inspection product within error range is passed after machine image processing. Also, the results and numbers are stored by users.

Seperate Driving System For Large Area X-ray Detector In Radiology (대면적 X-ray 검출기를 위한 분할 구동 시스템)

  • Lee, D.G.;Park, J.K.;Kim, D.H.;Nam, S.H.;Ahn, S.H.;Park, H.D.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.388-391
    • /
    • 2003
  • The properties of these detectors can be controlled by electronics and exposure conditions. Flat-panel detectors for digital diagnostic imaging convert incident x-ray images to charge images. Flat panel detectors gain more interest real time medical x-ray imaging. Active area of flat panel detector is $14{\times}17$ inch. Detector is based on a $2560{\times}3072$ away of photoconductor and TFT pixels. X-ray conversion layer is deposited upper TFT array flat panel with a 500m by thermal deposition technology. Thickness uniformity of this layer is made of thickness control technology(5%) of thermal deposition system. Each $139m{\times}139m$ pixel is made of thin film transistor technology, a storage capacitor and charge collection electrode having geometrical fill factor of 86%. Using the separate driving system of two dimensional mosaic modules for large area, that is able to 4.2 second per frame. Imaging performance is suited for digital radiography imaging substitute by conventional radiography film system..

  • PDF

Evaluation of Image Qualities for a Digital X-ray Imaging System Based on Gd$_2$O$_2$S(Tb) Scintillator and Photosensor Array by Using a Monte Carlo Imaging Simulation Code (몬테카를로 영상모의실험 코드를 이용한 Gd$_2$O$_2$S(Tb) 섬광체 및 광센서 어레이 기반 디지털 X-선 영상시스템의 화질평가)

  • Jung, Man-Hee;Jung, In-Bum;Park, Ju-Hee;Oh, Ji-Eun;Cho, Hyo-Sung;Han, Bong-Soo;Kim, Sin;Lee, Bong-Soo;Kim, Ho-Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.253-259
    • /
    • 2004
  • in this study, we developed a Monte Carlo imaging simulation code written by the visual C$\^$++/ programing language for design optimization of a digital X-ray imaging system. As a digital X-ray imaging system, we considered a Gd$_2$O$_2$S(Tb) scintillator and a photosensor array, and included a 2D parallel grid to simulate general test renditions. The interactions between X-ray beams and the system structure, the behavior of lights generated in the scintillator, and their collection in the photosensor array were simulated by using the Monte Carlo method. The scintillator thickness and the photosensor array pitch were assumed to 66$\mu\textrm{m}$ and 48$\mu\textrm{m}$, respertively, and the pixel format was set to 256 x 256. Using the code, we obtained X-ray images under various simulation conditions, and evaluated their image qualities through the calculations of SNR (signal-to-noise ratio), MTF (modulation transfer function), NPS (noise power spectrum), DQE (detective quantum efficiency). The image simulation code developed in this study can be applied effectively for a variety of digital X-ray imaging systems for their design optimization on various design parameters.

Image Restoration Simulation of Digital X-ray Images Based upon Filtering Techniques and the Quality Evaluation of the Restored Images (다양한 필터링 기법을 이용한 디지털 X-선 영상복원 시뮬레이션 및 정량적 화질평가)

  • Lee, So-Young;Choi, Sung-Il;Oh, Ji-Eun;Cho, Hee-Moon;Lee, Sung-Ju;Park, Yeon-Ok;Cho, Hyo-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.4
    • /
    • pp.33-40
    • /
    • 2008
  • Images acquired by a digital X-ray imaging system are inherently degraded due to system degradation process and additive noise sources. The system degradation in image quality is typically described as the system response function characterized by the modulation transfer function (MTF) and the noise term described as the noise power spectrum (NPS). In this case, we can restore the blur image as close as possible to the original image by using modified filtering designed for digital imaging system, as we know more precisely about the MTF and the NPS. In this paper, by performing simulation, we tried to restore blurred images taken from a digital X-ray imaging system based upon conventional filtering techniques such as a direct-inverse filtering, limited-inverse filtering, or a Wiener filtering, and evaluated the characteristics of the image restoration.

  • PDF

Development of Agricultural Products Screening System through X-ray Density Analysis

  • Eunhyeok Baek;Young-Tae Kwak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.4
    • /
    • pp.105-112
    • /
    • 2023
  • In this paper, we propose a new method for displaying colored defects by measuring the relative density with the wide-area and local densities of X-ray. The relative density of one pixel represents a relative difference from the surrounding pixels, and we also suggest a colorization of X-ray images representing these pixels as normal and defective. The traditional method mainly inspects materials such as plastics and metals, which have large differences in transmittance to the object. Our proposed method can be used to detect defects such as sprouts or holes in images obtained by an inspection machine that detects X-rays. In the experiment, the products that could not be seen with the naked eye were colored with pests or sprouts in a specific color so that they could be used in the agricultural product selection system. Products that are uniformly filled with a single ingredient inside, such as potatoes, carrots, and apples, can be detected effectively. However, it does not work well with bumpy products, such as peppers and paprika. The advantage of this method is that, unlike machine learning, it doesn't require large amounts of data. The proposed method could be applied to a screening system using X-rays and used not only in agricultural product screening systems but also in manufacturing processes such as processed food and parts manufacturing, so that it can be actively used to select defective products.

Leision Detection in Chest X-ray Images based on Coreset of Patch Feature (패치 특징 코어세트 기반의 흉부 X-Ray 영상에서의 병변 유무 감지)

  • Kim, Hyun-bin;Chun, Jun-Chul
    • Journal of Internet Computing and Services
    • /
    • v.23 no.3
    • /
    • pp.35-45
    • /
    • 2022
  • Even in recent years, treatment of first-aid patients is still often delayed due to a shortage of medical resources in marginalized areas. Research on automating the analysis of medical data to solve the problems of inaccessibility for medical services and shortage of medical personnel is ongoing. Computer vision-based medical inspection automation requires a lot of cost in data collection and labeling for training purposes. These problems stand out in the works of classifying lesion that are rare, or pathological features and pathogenesis that are difficult to clearly define visually. Anomaly detection is attracting as a method that can significantly reduce the cost of data collection by adopting an unsupervised learning strategy. In this paper, we propose methods for detecting abnormal images on chest X-RAY images as follows based on existing anomaly detection techniques. (1) Normalize the brightness range of medical images resampled as optimal resolution. (2) Some feature vectors with high representative power are selected in set of patch features extracted as intermediate-level from lesion-free images. (3) Measure the difference from the feature vectors of lesion-free data selected based on the nearest neighbor search algorithm. The proposed system can simultaneously perform anomaly classification and localization for each image. In this paper, the anomaly detection performance of the proposed system for chest X-RAY images of PA projection is measured and presented by detailed conditions. We demonstrate effect of anomaly detection for medical images by showing 0.705 classification AUROC for random subset extracted from the PadChest dataset. The proposed system can be usefully used to improve the clinical diagnosis workflow of medical institutions, and can effectively support early diagnosis in medically poor area.

Development of Liquid Crystal Optic Modulation Based X-ray Dosimeter by Using CdS Sensor (CdS 센서를 이용한 액정 광변조 X-선 검출 시스템 개발)

  • Noh, Si-Cheol;Kang, Sang-Sik;Jung, Bong-Jae;Choi, Il-Hong;Kim, Hyun-Hee;Cho, Chang-Hoon;Park, Jun-Hong;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.357-361
    • /
    • 2011
  • In this study, the liquid-crystal optical modulation X-ray detection system using a CdS which is a family of II-IV compound semiconductor was proposed. The system consist of the detector, the signal processing part, the liquid-crystal driving parts, microcontroller, and I/O parts, and was designed to be suitable for miniaturization and portable. In addition, the system can measure a wide range X-ray by using the detecting range selection. In order to evaluate the performance of the proposed system, the CdS sensor's output characteristics were confirmed in accordance with changes of dose, and excellent correlation was determined. And also, the optical penetration ratio was discussed in accordance with changes of the applied voltage by measuring the change of the liquid-crystal in accordance with changes of the applied voltage. Through these results, the characteristics of the liquid-crystal optical modulation system such as the excellent reproducibility and the noise immunity were confirmed. And we considered that the CdS cell-based liquid-crystal optical modulated portable X-ray detection system could be applied to compact, low-cost, portable system.

Image Quality Evaluation according to X-ray Source Arrangement Type and the Number of Projections in a s-IGDT System (s-IGDT 시스템의 X-선원 배열 형태 및 투영상 개수에 따른 영상 화질 평가에 관한 연구)

  • Lee, Dahye;Nam, KiBok;Lee, Seungwan
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.117-125
    • /
    • 2022
  • Although stationary inverse-geometry digital tomosynthesis (s-IGDT) is able to reduce motion artifacts, image acquisition time and radiation dose, the image quality of the s-IGDT is degraded due to the truncations arisen in projections. Therefore, the effects of geometric and image acquisition conditions in the s-IGDT should be analyzed for improving the image quality and clinical applicability of the s-IGDT system. In this study, the s-IGDT images were obtained with the various X-ray source arrangement types and the various number of projections. The resolution and noise characteristics of the obtained s-IGDT images were evaluated, and the characteristics were compared with those of the conventional DT images. The s-IGDT system using linear X-ray source arrangement and 40 projections maximized the image characteristics of resolution and noise, and the corresponding system was superior to the conventional DT system in terms of image resolution. In conclusion, we expect that the s-IGDT system can be used for providing medical images in diagnosis.

(Automatic detection of pulmonary nodules in X-ray chest images) (흉부 X선 영상에서의 폐 노쥴 자동 탐지 기법)

  • Sung, Won;Kim, Eui-Jung;Park, Jong-Won
    • Journal of the Korea Computer Industry Society
    • /
    • v.3 no.9
    • /
    • pp.1279-1286
    • /
    • 2002
  • Generally, radiologists can fail to detect pulmonary nodules in up to 30%. If an automatic system can inform the radiologists of thelocations of the doubtful nodules in the X-ray chest images, the frequency of mistakenly observed numbers of the nodules can be potentially reduced. This software is using morphological filtering and two feature-extraction techniques. The morphological filtering is the first process, which subsequently adds the operations of erosion and dilation to the original images so that this process can transform the original X-ray chest images into manageable ones. The false-positives are frequently being mistaken as nodules but actually these are not real nodules. The second process is the two feature-extraction techniques which are used to reduce the false-positives. Therefore, this system will make more effective detection of pulmonary nodules by reducing the false-positives when applied to the X-ray chest images which is difficult to get accurate detection.

  • PDF

The Convergence Application Example of Non-destructive Inspection System (비파괴 검사 시스템의 융합 적용 사례)

  • Lee, Jeong-Ick
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.3
    • /
    • pp.191-197
    • /
    • 2017
  • This development is for non-destructive machine using X-Ray source about detecting outline faults of below middle size products. The differentiation is product of research and development unspecialized small and medium-sized products using X-Ray light sources can check real time if the surface of an external fault of radiation dose reference, within the leakage. The speed control is possible by software solution. In addition, we're working on possibly block doors for worker safety and equipment at the same time that inner drive can be identified in the image. These principles, as a key enabler of the current inspection system such as the container is small to medium-sized parts - a long way from utilization level is possible. This research will give rise to major effects for other various non-destructive market industries except car-industry. The most important fact is that this developed non-destructive machine is controlled below $0.2micro-S{\mu}v$.