Abstract
Although stationary inverse-geometry digital tomosynthesis (s-IGDT) is able to reduce motion artifacts, image acquisition time and radiation dose, the image quality of the s-IGDT is degraded due to the truncations arisen in projections. Therefore, the effects of geometric and image acquisition conditions in the s-IGDT should be analyzed for improving the image quality and clinical applicability of the s-IGDT system. In this study, the s-IGDT images were obtained with the various X-ray source arrangement types and the various number of projections. The resolution and noise characteristics of the obtained s-IGDT images were evaluated, and the characteristics were compared with those of the conventional DT images. The s-IGDT system using linear X-ray source arrangement and 40 projections maximized the image characteristics of resolution and noise, and the corresponding system was superior to the conventional DT system in terms of image resolution. In conclusion, we expect that the s-IGDT system can be used for providing medical images in diagnosis.
Keywords
s-IGDT; X-ray source arrangement; Number of projections; Resolution; Noise;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Kirby JS, Armato SG, Drukker K, Li F, Hadjiiski L, Tourassi GD, et al. LUNGx Challenge for computerized lung nodule classification. Journal of Medical Imaging. 2016;3(4):044506.   DOI
2 Andersen AH, Kak AC. Simultaneous Algebraic Reconstruction Technique (SART): A Superior Implementation of the ART Algorithm. Ultrasonic Imaging. 1984;6(1):81-94.   DOI
3 Gomi T, Hirano H. Clinical Potential of Digital Linear Tomosynthesis Imaging of Total Joint Arthroplasty. Journal of Digital Imaging. 2008;21(3):312-22.   DOI
4 Tucker AW, Lu J, Zhou O. Dependency of image quality on system configuration parameters in a stationary digital breast tomosynthesis system. Medical Physics. 2013;40(3):031917.   DOI
5 Fukui R, Matsuura R, Kida K, Goto S. Effect of the Number of Projected Images on the Noise Characteristics in Tomosynthesis Imaging. Progress in Medical Physics. 2021;32(4):50-8.   DOI
6 Maldera A, Marco PD, Colombo PE, Origgi D, Torresin A. Digital breast tomosynthesis: Dose and image quality assessment. Physica Medica. 2017;33:56-67.   DOI
7 Lee D, Yim D, Nam K, Kim S, Lee S. Effect of Tilted Source Trajectory on Image Quality in Stationary-Inverse Geometry Digital Tomosynthesis. The 9th Korea-Japan Joint Meeting on Medical Physics. 2021.
8 Tirada N, Li G, Dreizin D, Robinson L, Khorjekar G, Dromi S, et al. Digital Breast Tomosynthesis: Physics, Artifacts, and Quality Control Considerations. Radiographics. 2019;39(2):413-26.   DOI
9 Siddon RL. Fast calculation of the exact radiological path for a three-dimensional CT array. Medical Physics. 1985;12(2):252-5.   DOI
10 Hu YH, Zhao B, Zhao W. Image artifacts in digital breast tomosynthesis: Investigation of the effects of system geometry and reconstruction parameters using a linear system approach. Medical Physics. 2008;35(12):5242-52.   DOI
11 Hong E, Lee I. Suggestion of The Manual Exposure Condition Guideline for Reducing Patient Dose in Digital Breast Tomosynthesis. Journal of Radiological Science and Technology. 2016;39(4):483-91.   DOI
12 Gomi T, Nakajima H, Fujiwara H, Takeda T, Saito K, Umeda T, et al. Comparison between chest digital tomosynthesis and CT as a screening method to detect artificial pulmonary nodules: A phantom study. British Journal of Radiology. 2012;85(1017):e622-9.   DOI
13 Zhang Y, Chan HP, Sahiner B, Wei J, Zhou C, Hadjiiski LM. Artifact reduction methods for truncated projections in iterative breast tomosynthesis reconstruction. Journal of Computer Assisted Tomography. 2009;33(3):426-35.   DOI
14 Dobbins JT, Godfrey DJ. Digital x-ray tomosynthesis: Current state of the art and clinical potential. Physics in Medicine and Biology. 2003;48(19):R65-106.   DOI
15 Kim K, Kim S. Comparison of Image Quality and Effective Dose by Additional Filtration on Digital Chest Tomosynthesis. Journal of Radiological Science and Technology. 2015;38(4):347-53.   DOI
16 Dobbins JT. Tomosynthesis imaging: At a translational crossroads. Medical Physics. 2009;36(6):1956-67.   DOI
17 Lee Y, Lee S. Geometric dependence of image quality in digital tomosynthesis: Simulations of X-ray source trajectories and scan angles. Nuclear Instruments and Methods in Physics Research Section A. 2020;969(21):163997.   DOI
18 Sechopoulos I, Ghetti C. Optimization of the acquisition geometry in digital tomosynthesis of the breast. Medical Physics. 2009;36(4):1199-207.   DOI
19 Speidel MA. Inverse geometry x-ray imaging: Application in interventional procedures. Journal of American College of Radiology. 2011;8(1):74-7.   DOI
20 Qian X, Tucker A, Gidcumb E, Shan J, Yang G, Calderon-Colon X, et al. High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x-ray source array. Medical Physics. 2012;39(4):2090-9.   DOI
21 Son J, Choi S, Lee D, Kim H. Truncation artifact reduction using weighted normalization method in prototype R/F chest digital tomosynthesis (CDT) system. Journal of Korean Society of Radiology. 2019;13(1):111-8.   DOI
22 Wang X, Mainprize JG, Kempston MP, Mawdsley GE, Yaffe MJ. Digital breast tomosynthesis geometry calibration. Proceedings of SPIE Medical Imaging. 2007;6510(65103B).
23 Chighvinadze T, Pistorius S. The impact of the number of projections on image quality in Compton scatter tomography. Journal of X-ray Science and Technology. 2015;23(6):745-58.   DOI