• 제목/요약/키워드: X-Ray Projection

검색결과 143건 처리시간 0.024초

경사조사(傾斜照射) 강판튜브 방사선영상 영역특성 분석 (Discrimination for Line-clustering Segmental Approach to Steel-tube X-ray Image)

  • 황중원;황재호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.399-400
    • /
    • 2007
  • This paper proposes an regional analytic approach in image data space for radiographic image. Image is segmented into four regions, such as background, thickness, weld area and tube area, due to directional properties. Each region has its own gray level distribution, contrast range and noise property, originated from X-ray project mechanism and electric control system itself. Projection incorrectness and noise influence included on imaging quality is analyzed functionally and statistically. The experimental results shows not only segmental effects, but also visual edge evaluation.

  • PDF

패치 특징 코어세트 기반의 흉부 X-Ray 영상에서의 병변 유무 감지 (Leision Detection in Chest X-ray Images based on Coreset of Patch Feature)

  • 김현빈;전준철
    • 인터넷정보학회논문지
    • /
    • 제23권3호
    • /
    • pp.35-45
    • /
    • 2022
  • 현대에도 일부 소외된 지역에서는 의료 인력의 부족으로 인해 위·중증 환자에 대한 치료가 지연되는 경우가 많다. 의료 데이터에 대한 분석을 자동화하여 의료 서비스의 접근성 문제 및 의료 인력 부족을 해소하고자 하는 연구가 계속되고 있다. 컴퓨터 비전 기반의 진료 자동화는 훈련 목적에 대한 데이터 수집 및 라벨링 작업에서 많은 비용이 요구된다. 이러한 점은 희귀질환이나 시각적으로 뚜렷하게 정의하기 어려운 병리적 특징 및 기전을 구분하는 작업에서 두드러진다. 이상 탐지는 비지도 학습 전략을 채택함으로써 데이터 수집 비용을 크게 절감할 수 있는 방법으로 주목된다. 본 논문에서는 기존의 이상 탐지 기법들을 기반으로, 흉부 X-RAY 영상에 대해 이상 탐지를 수행하는 방법을 다음과 같이 제안한다. (1) 최적 해상도로 샘플링된 의료 영상의 색상 범위를 정규화한다. (2) 무병변 영상으로부터 패치 단위로 구분된 중간 수준 특징 집합을 추출하여 그 중 높은 표현력을 가진 일부 특징 벡터들을 선정한다. (3) 최근접 이웃 탐색 알고리즘을 기반으로 미리 선정된 무병변(정상) 특징 벡터들과의 차이를 측정한다. 본 논문에서는 PA 방식으로 촬영된 흉부 X-RAY 영상들에 대한 제안 시스템의 이상 탐지 성능을 세부 조건에 따라 상세히 측정하여 제시한다. PadChest 데이터세트로부터 추출한 서브세트에 대해 0.705 분류 AUROC를 보임으로써 의료 영상에 대한 이상 탐지 적용의 효과를 입증하였다. 제안 시스템은 의료 기관의 임상 진단 워크플로우를 개선하는 데에 유용하게 사용될 수 있으며, 의료 서비스 접근성이 낮은 지역에서의 조기 진단을 효율적으로 지원할 수 있다.

저조사광 재구성을 위한 필터 설계 (Modifcation of Reconstruction Filter for Low-Dose Reconstruction)

  • 염영호
    • 대한전자공학회논문지
    • /
    • 제17권1호
    • /
    • pp.23-30
    • /
    • 1980
  • C.T.(전산화 단층 영상 처리) 영상재구성의 경우, 투사되는 광양자(X-ray, positron 등)가 적을 때는 잡음에 의한 효과가 증폭되어 재구성된 화면은 거의 알아 볼 수 없게 된다. 그 경우 화질을 높이깅 nl해서는 재구성 필터를 사영 데이터(projection data)의 신호대잡음비에 따라 수정시켜야 할 필요성이 생긴다. 이 논문에서는 사영 데이터에서 얻은 정보를 사용하여 재구성 필터를 수정하는 방법에 관하여 고찰하고 그에 대한 시뮬레이션을 행하였다. 시뮬레이션의 결과, 이 방법은 재구성 화상에서의 잡음을 줄여, 그 분해능력을 크게 향상시킬 수 있음이 판명되었다. 또한 이 필터를 근사적으로 구현하는 방법에 관하여도 논하고, 그 근사 필터의 회귀적 구성(recursive implementation)의 가능성에 관하여도 언급하였다.

  • PDF

ALGEBRAIC CORRECTION FOR METAL ARTIFACT REDUCTION IN COMPUTED TOMOGRAPHY

  • Jeon, Kiwan;Kang, Sung-Ho;Ahn, Chi Young;Kim, Sungwhan
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제18권2호
    • /
    • pp.157-166
    • /
    • 2014
  • If there are metals located in the X-ray scanned object, a point outside the metals has its range of projection angle at which projections passing through the point are disturbed by the metals. Roughly speaking, this implies that attenuation information at the point is missing in the blocked projection range. So conventional projection completion MAR algorithms to use the undisturbed projection data on the boundary of the metaltrace is less efficient in reconstructing the attenuation coefficient in detailed parts, in particular, near the metal region. In order to overcome this problem, we propose the algebraic correction technique (ACT) to utilize a pre-reconstructed interim image of the attenuation coefficient outside the metal region which is obtained by solving a linear system designed to reduce computational costs. The reconstructed interim image of the attenuation coefficient is used as prior information for MAR. Numerical simulations support that the proposed correction technique shows better performance than conventional inpainting techniques such as the total variation and the harmonic inpainting.

The ability of panoramic radiography in assessing maxillary sinus inflammatory diseases

  • Nah, Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • 제38권4호
    • /
    • pp.209-213
    • /
    • 2008
  • Purpose : To evaluate the relative diagnostic accuracy of panoramic radiography and Water's projection in maxillary sinus inflammatory diseases by comparing the radiodensities of the images with those of CT. Materials and Methods : Panoramic radiographs, Waters' projection, and CT images from 55 subjects (11O sinuses) were included in this retrospective study. The radiodensity of each maxillary sinus in panoramic radiography was recorded separately as upper and lower divided horizontally by hard palate. In Waters' projection, the overall sinus radiodensity was recorded. The CT images were considered as gold standard. Results : In panoramic radiography, 83 sinuses had same upper and lower radiodensity and 72 of these were consistent with those of CT, 26 sinuses had different upper and lower radiodensity and 15 of these, upper radiodensity was consistent with CT, the remaining 11, lower radiodensity was consistent with CT. One sinus had upper radiolucency with lower radiopacity and both were consistent with those of CT. Altogether 73 (66.4%) among 110 sinuses in panoramic radiography showed full agreement with CT, 26 (23.6%) showed partial agreement with CT. 9 sinuses had no lower image under the hard palate in panoramic radiography due to the smaller size of sinus. In Waters' projection, the radiodensity of 105 sinuses (95.5%) were consistent with that of CT. Conclusion : The panoramic radiography showed 90.0% of the sinus conditions fully or partially which may appear less accurate than that of Water's view (95.5%) but with more detailed information of the inferior part of sinuses. (Korean J Oral Maxillofac Radiol 2008; 38 : 209-13)

  • PDF

방사선촬영에서 면적선량 및 새로운 실질면적선량 개념의 비교 평가 (Comparative Evaluation of Kerma Area Product and New Fundamental of Kerma Area Product on Radiography)

  • 최우철;김용민;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.53-58
    • /
    • 2021
  • Kerma Area Product (KAP) is best indicator of radiation monitoring on radiographic examinations. KAP can be measured differently depending on the X-ray irradiation area, air kerma, souce-skin distance, type of equipment, etc. The major factors are exposure area and the air krema. The KAP currently used only considers the exposure area with X-rays and has a problem that KAP is always excessively overestimated from the dose received by an actual subject. Therefore, in this study, in order to measure the accurate KAP, a new area dose calculation that can be calculated by dividing the area where the actual X-ray is irradiated is presented, and the KAP is the real area. We compared and analyzed how much it was overestimated compared to the dose. The Skull AP projection and seven other projection were compared and analyzed, and the KAP was overestimated in each test by 52% to 60%. In this way, the effective KAP (EKAP) calculation developed through this study should be utilized to prevent extra calculation of the existing KAP, and only the accurate patient subject area should be calculated to derive the accurate area dose value. EKAP is helpful for control the patient's exposure dose more finely, and it is useful for the quality control of medical radiation exposure.

영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구 (Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy)

  • 김진성;조민국;조영빈;윤한빈;김호경;윤명근;신동호;이세병;이레나;박성용;조관호
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.209-218
    • /
    • 2008
  • IMRT, 양성자 치료와 같이 방사선 치료 기술이 발전할수록 치료 시 환자의 위치를 확인하고 그 정확성을 평가하는 기술의 중요성이 강조되고 있다. 현재 국립암센터 양성자치료센터에 설치되어 있는 양성자 치료기의 단순 X-선 영상시스템을 이용하여 콘빔 CT (cone-beam CT) 3차원 영상을 획득, 영상유도 방사선 치료의 가능성을 확인하고자 하였다. 양성자 치료기에 설치되어있는 X-선 영상시스템(SDD: 2,108 mm, SOD: 1,511 mm, Varian a277 x-ray tube & Varian Paxscan 4030: a-Si+DRZ screen)을 이용하여 양성자 갠트리를 $2^{\circ}$씩 회전시켜가면서 기하학적인 오차 측정을 위한 팬톰과 인체 팬톰 (Humanoid phantom, Rando, CA, USA)의 투사영상을 획득하였다. 현재 시스템적으로 연속적인 회전과 영상획득이 지원되지 않아서 영상획득 후 갠트리를 회전하는 방법으로 투사영상을 획득하였다. 기하학적 오차측정을 위한 팬텀과 두경부 팬텀에 대해서 $360^{\circ}$를 회전하며 180장의 투사영상($2,304{\times}3,200$, 14 bit with 127${\mu}m$ pixel pitch)을 관전압 85 kVp, 관전류 80 mA, 조사시간 0.5 s의 조건으로 촬영하였다. 콘빔 CT 영상재구성을 위해 Ram-Lak filter를 적용한 Feldkamp cone-beam 알고리즘을 사용하였으며, 획득한 180장의 투사영상을 사용하여 $0.4{\times}0.4{\times}0.4mm^3$의 voxel size를 가진 $512{\times}512{\times}512$ CT영상을 재구성하였다. 기하학적인 오차 측정방법을 통해 X-선 선원, 검출기와 갠트리의 기하학적 정보를 측정하였다. 측정된 결과에 의하면 검출기가 $0.25^{\circ}$ 회전된 오차를 보이는 것을 발견하였다. 기하학적 교정으로 재구성된 콘빔 CT 영상을 multi-planar view (axial, sagittal and coronal view) 및 3차원 영상으로 재구성하여 비교 평가 하였다. 현재 양성자치료기에 설치되어있는 단순 X-선 영상 시스템에서 기하학적 오차 측정을 위한 볼 팬텀을 이용하여 시스템의 오차를 측정하였다. 측정한 오차를 바탕으로 기하학적 교정을 통해서 두경부 및 복부 팬텀에 대한 3차원 영상인 콘빔 CT 영상들을 재구성하였다. 추후 연속적인 회전을 통한 영상획득이 가능하게 된다면, 보다 정확하고 신속한 영상재구성이 가능 하며 콘빔 CT가 영상유도 양성자 치료에 매우 유용할 것으로 사려된다.

  • PDF

유아 발 전체의 뼈에 대한 합성 전후축방향 엑스선촬영법 연구 (A Composite DorsoPlantar Axial X-ray Projection Study on the Bones of the Whole Infant's Foot)

  • 박윤;안병주
    • 한국방사선학회논문지
    • /
    • 제15권7호
    • /
    • pp.1007-1013
    • /
    • 2021
  • 본 연구는 유아 발의 합성 전후축방향 엑스선 촬영에서 발전체가 다리와 겹침 없이 균일한 농도와 선예한 영상을 평가하기 위하여 Receiver Operating Characteristic 와 Signal to Noise Ratio 분석 결과 Cronbach Alpha 값이 0.813로 유의하게 높았으며 신호대잡음비(SNR)의 연구에서는 발허리뼈에서 발꿈치뼈를 향하여 엑스선관을 10° 기울여 검사 시 5.948 높게 나타났으며, 발꿈치뼈에서 발허리뼈를 향하여 엑스선관을 20° 기울여 검사 시 6.957으로 가장 높았다. 또한, 주관적평가에서는 발허리뼈에서 발꿈치뼈로 10° 기울려 검사시 18점으로 높은 점수를 얻었으며, 발꿈치뼈에서 발허리쪽뼈을 향하여 엑스선관을 20° 기울여 검사 시 18 점을 얻었다. 본 연구의 결과 유아 발 합성 전후축방향 검사 시 엑스선관을 발허리뼈 뒤쪽으로 10° 기울였을 경우와 발꿈치뼈에서 전방으로 20° 기울였을 때 균일한 농도와 선예한 영상을 얻을 수 있다.

현장 적용이 가능한 X선 CT 시스템 개발 II- 밀도분포를 이용한 목재의 CT영상 구성 - (Development of Portable X-ray CT System II - CT Image Reconstruction of Wood using Density Distribution -)

  • 김광모;이상준;이전제
    • Journal of the Korean Wood Science and Technology
    • /
    • 제34권1호
    • /
    • pp.23-31
    • /
    • 2006
  • X선은 강한 투과성과 직진성으로 인하여 비파괴 검사법으로써 다양한 분야에서 활용되고 있다. 본 연구에서는 고건축물과 같은 목조 건축물에 사용되고 있는 구조부재의 열화를 현장에서 탐지할 수 있는 비파괴 검사법을 개발할 목적으로 X선 CT시스템의 적용가능성을 검토하였다. 먼저 이전 연구의 결과를 바탕으로 CT영상을 구성하는 체계를 확립하고, 얻어진 CT영상을 실제 부재의 단면 형태와 비교함으로써 개발된 시스템의 적용가능성을 확인하였다. 개발된 X선 CT시스템의 적용을 통해 결함의 형태와 크기, 위치뿐만 아니라 결함에서의 밀도 또한 비교적 정확하게 탐지할 수 있음이 확인되었다. 이러한 결과는 건축물에서 사용되고 있는 목재 부재에 열화가 발생하였을 경우에, 열화 발생의 원인을 파악하고 그에 따른 효과적인 대처방안을 수립하는데 있어서 유용하게 활용될 수 있을 것으로 기대된다. 그러나 현재의 시스템은 개발 초기단계로 측정에 따른 소요시간이나 측정회수, 측정 정밀도에 있어서 여러 제약을 받는다. 따라서 이러한 제약을 극복하기 위한 추가적인 연구가 요구된다.

반도체 공정용 리소그래피 기술의 최근 동향 (Recent Trends of Lithographic Technology)

  • 정태진;유종준
    • 전자통신동향분석
    • /
    • 제13권5호통권53호
    • /
    • pp.38-52
    • /
    • 1998
  • Phase-shifting masks (PSM), optical proximity correction (OPC), off-axis illumination (OAI), annular illumination (AI)의 리소그래피 분해능 향상 기법과 deep ultraviolet photoresist의 개발 및 리소그래피의 최근 기술 동향을 요약 소개한다. DUV 리소그래피의 대안으로 관심을 끌고 있는 scattering with angular limitation projection electron-beam lithography (SCALPEL), extreme ultraviolet lithography (EUVL), X-ray lithography (XRL), ion projection lithography (IPL) 등의 새로운 리소그래피 기술들의 기본 원리와 최근 기술 동향도 소개하였다. 리소그래피는 반도체 공정에 있어서 가장 중요한 부분을 차지하기 때문에 리소그래피의 최근 기술 동향을 검토해 봄으로써 국내 리소그래피 장비 산업의 기술 개발을 위한 방향 설정에 도움이 될 것으로 생각한다.