Artifact Reduction in Digital Radiography Images with the Stationary Grid Based on 1-Dimensional Filters (고정 그리드를 사용한 디지털 방사선 영상에서 1차원 필터에 기초한 왜곡의 제거)

  • Kim, Dong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.5
    • /
    • pp.117-126
    • /
    • 2010
  • In order to obtain more clear x-ray images, an antiscatter grid, which can absorb the scattered rays, is employed. In the high-resolution direct digital radiography, however, the artifacts due to the grid are visible. In this paper, the grid artifacts are reduced by applying simple 1-dimensional low-pass filters in the spatial domain based on the rotated grid. Since the proposed algorithm does not use any detection scheme for the artifact frequencies and discrete Fourier transforms for 2-dimensional filters, it can simply and fast reduce the grid artifacts. The performance using the order 1 average filter is compatible to that of using 2-dimensional filters in the frequency domain.

Analysis of the minimum exposure position according to the additional filtration plate (부가여과판에 따른 최소한의 피폭 위치에 대한 분석)

  • Tae-Ri, Kim;Min-Ji, Kang;Sang-Hee, La;Yun-Jeong, Shin;Tae-Gyeom, Hong;Min-Cheol, Jeon
    • Journal of Advanced Technology Convergence
    • /
    • v.1 no.2
    • /
    • pp.11-17
    • /
    • 2022
  • The purpose is to find out where medical workers can receive the minimum radiation does in clinical. In order to sett RQR standard quality of radiation, put a Al 1.5mm filter(row and column: 10 cm × 10 cm) on X-ray tube. Al 0.9 mm, Cu 0.3 mm, Ni 0.3 mm used as a filter. The Acrylic phantom were set to 13.1 cm, 18.5 cm, 21.1 cm. by the object thickness was different. As a results, when we use Al 0.9 mm, 1853 nSv was the highest numeral. It is a point of anode low 50 cm, when we use 13.1 cm Acrylic phantom. When we use Cu 0.3 mm, 173 nSv was the lowest numeral. It is a point of anode low 150 cm, when we use 13.1 cm Acrylic Phantom. In this study, it was confirmed that the spatial scattering dose decreased as the distance from the X-ray tube increased. It is considered that more studies on the exposure of scattered doses are needed in the future.

고에너지 이온선을 이용한 분석 기술

  • 김효배;송종한;김희중
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.2
    • /
    • pp.122-129
    • /
    • 1996
  • Fig. 1에서 보는 바와 같이 수 MeV의 에너지를 가진 입사이온이 고체 시료표면과 충돌했을 때 여러 가지의 상호작용과 과정들이 일어난다. 입사 아온이 표적원자의 원자가전자나 내각전자와 상호작용을 하였을 때 원자를 여기시키거나 이온화시키게 되며 입사 이온이 표적 핵과 매우 가까이 접근했을 때 입사이온과 표적 핵사이에 쿨롱상호작용이나 핵 상호작용이 일어나게 된다. 이러한 여러가지 상호작용의 결과들로부터 분석하고자 하는 시료의 성분, 구조, 상호작용 과정에 대한 정보를 얻을 수 있다. 이러한 고에너지 이온선을 이용한 분석기술로는 Fig. 1에서 보는 바와 같이 후방산란법(BS : Backscattering Spectrometry), 전방산란법(FRS : Forward Recoil Spectrometry), 핵반응법(NRA : Nuclear Reaction Analysis), 양성자여기X선검출법(PIXE : Proton Induced X-ray Emission)등과 이러한 방법들과 같이 조합하여 사용하는 이온 채널링(ion channeling)등이 있다. 본 해설에서는 이러한 분석법중에서도 널리 사용되고 있는 후방산란법과 이온 채널링에 대하여 주로 기술하고자 한다.

  • PDF

An Experimental Method for the Scatter Correction of MV Images Using Scatter to Primary Ratios (SPRs) (산란선 대 일차선비(SPR)를 이용한 MV 영상의 산란 보정을 위한 실험적 방법)

  • Jeon, Hosang;Park, Dahl;Lee, Jayeong;Nam, Jiho;Kim, Wontaek;Ki, Yongkan;Kim, Donghyun;Lee, Ju Hye;Kim, Dongwon
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.143-150
    • /
    • 2014
  • In general radiotherapy, mega-voltage (MV) x-ray images are widely used as the unique method to verify radio-therapeutic fields. But, the image quality of MV images is much lower than that of kilo-voltage x-ray images due to scatter interactions. Since 1990s, studies for the scatter correction have performed with digital-based MV imaging systems. In this study, a novel method for the scatter correction is suggested using scatter to primary ratio (SPR), instead of conventional methods such as digital image processing or scatter kernel calculations. We measured two MV images with and without a solid water phantom describing a patient body with given imaging conditions, and calculated un-attenuated ratios. Then, we obtained SPR distributions for the scatter correction. For experimental validation, a line-pair (LP) phantom using several Al bars and a clinical pelvis MV image was used. As the result, scatter signals of the LP phantom image were successfully reduced so that original density distribution of the phantom was restored. Moreover, image contrast values increased after SPR correction at all ROIs of the clinical image. The mean value of increases was 48%. The SPR correction method suggested in this study has high reliability because it is based on actually measured data. Also, this method can be easily adopted in clinics without additional cost. We expected that the SPR correction can be an effective method to improve the quality of MV image guided radiotherapy.

The Variation of Surface Dose by Beam Spoiler in 10 MV Photon Beam from Linear Accelerator (선형가속기 10 MV 광자선에서 산란판(Beam Spoiler) 사용 시 표면선량 변화)

  • Bae, Seong-Cheol;Kim, Jun-Ho;Lee, Choul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • Purpose: The purpose of this study is to find a optimal beam spoiler condition on the dose distribution near the surface, when treating a squamous cell carcinoma of the head and neck and a lymphatic region with 10 MV photon beam. The use of a optimal spoiler allows elivering high dose to a superficial tumor volume, while maintaining the skin-sparing effect in the area between the surface to the depth of 0.4 cm. Materials and Methods: The lucite beam spoiler, which were a tissue equivalent, were made and placed between the surface and the photon collimators of linear accelerator. The surface-dose, the dose at the depth of 0.4 cm, and the maximum dose at the dmax were measured with a parallel-plate ionization chamber for $5{\times}5cm\;to\;30{\times}30cm^2$ field sizes using lucite spoilers with different thicknesses at varying skin-to-spoiler separation (SSS). In the same condition, the dose was measured with bolus and compared with beam spoiler. Results: The spoiler increased the surface and build-up dose and shifted the depth of maximum dose toward the surface. With a 10 MV x-ray beam and a optimal beam spoiler when treating a patient, a similer build-up dose with a 6 MV photon beam could be achieved, while maintaining a certain amount of skin spring. But it was provided higher surface dose under SSS of less than 5 cm, the spoiler thickness of more than 1.8 cm or more, and larger field size than $20{\times}20cm^2$ provided higher surface dose like bolus and obliterated the spin-sparing effect. the effects of the beam spoiler on beam profile was reduced with increasing depths. Conclusion: The lucite spoiler allowed using of a 10 MV photon beam for the radiation treatment of head and neck caner by yielding secondary scattered electron on the surface. The dose at superficial depth was increased and the depth of maximum dose was moved to near the skin surface. Spoiling the 10 MV x-ray beam resulted in treatment plans that maintained dose homogeneity without the consequence of increased skin reaction or treat volume underdose for regions near the skin surface. In this, the optimal spoiler thickeness of 1.2 cm and 1.8 cm were found at SSS of 7 cm for $10{\times}10cm^2$ field. The surface doses were measured 60% and 64% respectively. In addition, It showed so optimal that 94% and 94% at the depth of 0.4 cm and dmax respectively.

  • PDF

Study on the Exposure Field of Head and Neck with Measurement of X-ray dose Distribution for Dental Panoramic X-ray System (치과 파노라마 장치의 X선 공간선량분포 측정을 통한 두경부 피폭영역 조사에 대한 연구)

  • Oh, Yoonjin;Hong, Girang;Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.17-21
    • /
    • 2015
  • Recently, As people's interest in the health of teeth is increased in the medical field changed into aging society, the number of times for the radiological diagnosis is increased. It can be said that the radiation exposure dose of Korean population is increased. It is also growing concern about radiation exposure. Therefore, the basic data for the dental panoramic X-ray system, its investigation and measuring the radiation dose is needed. In this study, we used ALOKA PDM-117 dosimeter and estimated a two-dimensional dose distribution of the dental panoramic X-ray system (VATEC Pax-400). Dose evaluation about the distribution is confirmed from the point of radiation exposure of a patient. Dose distribution of the dental panoramic X-ray system irradiated chin and the facial region to high dose as well as the parts of teeth. It was founded that the eye lens which are sensitive to radiation are exposed to unnecessary radiation, considering the effect of scattered radiation. The results of this study will be used more accurate dose assessment in a variety of object size and location of measuring dose.

Survey of Technical Parameters for Pediatric Chest X-ray Imaging by Using Effective DQE and Dose (유효검출양자효율과 선량을 이용한 소아 흉부 X-선 영상의 기술적인 인자에 관한 조사)

  • Park, Hye-Suk;Kim, Ye-Seul;Kim, Sang-Tae;Park, Ok-Seob;Jeon, Chang-Woo;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.163-171
    • /
    • 2011
  • The purpose of this study was to investigate the effect of various technical parameters for the dose optimization in pediatric chest radiological examinations by evaluating effective dose and effective detective quantum efficiency (eDQE) including the scatter radiation from the object, the blur caused by the focal spot, geometric magnification and detector characteristics. For the tube voltages ranging from 40 to 90 kVp in 10 kVp increments at the FDD of 100, 110, 120, 150, 180 cm, the eDQE was evaluated at the same effective dose. The results showed that the eDQE was largest at 60 kVp when compares the eDQE at different tube voltage. Especially, the eDQE was considerably higher without the use of an anti-scatter grid on equivalent effective dose. This indicates that the reducing the scatter radiation did not compensate for the loss of absorbed effective photons in the grid. When the grid is not used the eDQE increased with increasing FDD because of the greater effective modulation transfer function (eMTF). However, most of major hospitals in Korea employed a short FDD of 100 cm with an anti-scatter grid for the chest radiological examination of a 15 month old infant. As a result, the entrance surface air kerma (ESAK) values for the hospitals of this survey exceeded the Korean DRL (diagnostic reference level) of $100{\mu}Gy$. Therefore, appropriate technical parameters should be established to perform pediatric chest examinations on children of different ages. The results of this study may serve as a baseline to establish detailed reference level of pediatric dose for different ages.

The Necessity of Resetting the Filter Criteria for the Minimization of Dose Creep in Digital Imaging Systems (디지털 영상 시스템에서 선량 크리프 최소화를 위한 부가 필터 두께 권고 기준의 재설정에 대한 연구)

  • Kim, Kyo Tae;Kim, Kum Bae;Kang, Sang Sik;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.757-763
    • /
    • 2019
  • Recently, Following the recent development of flat panel detector with wide dynamic ranges, increasing numbers of healthcare providers have begun to use digital radiography. As a result, filter thickness standards should be reestablished, as current clinical practice requires the use of thicknesses recommended by the National Council on Radiation Protection and Measurements, which are based on information, acquired using conventional analog systems. Here we investigated the possibility of minimizing dose creep and optimizing patient dose using Al filters in digital radiography. The use of thicker Al filters resulted in a maximum 19.3% reduction in the entrance skin exposure dose when medical images with similar sharpness values were compared. However, resolution, which is a critical factor in imaging, had a significant change of 1.01 lp/mm. This change in resolution is thought to be due to the increased amount of scattered rays generated from the object due to the X-ray beam hardening effect. The increase in the number of scattered rays was verified using the scattering degradation factor. However, the FPD, which has recently been developed and is widely used in various areas, has greater response to radiation than analog devices and has a wide dynamic range. Therefore, the FPD is expected to maintain an appropriate level of resolution corresponding to the increase in the scattered-ray content ratio, which depends on filter thickness. Use of the FPD is also expected to minimize dose creep by reducing the exposure dose.

Annealing Effects on $Zn_{0.9}Cd_{0.1}$/Se/ZnSe Strained Single Quantum Well (Zn_{0.9}Cd_{0.1}/ZnSe 변형된 단일 양자우물구조의 열처리 효과)

  • 김동렬;배인호;손정식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.6
    • /
    • pp.467-471
    • /
    • 2000
  • The thermal annealing effect of $Zn_{0.9}Cd_{0.1}$ single quantum-well structures grown by molecular beam epitaxy is investigated. As the results of before and after rapid thermal annealed samples a red shift of E1-HH1 peak by Cd interdiffusion during thermal annealing of ZnCeSe/ZnSe sample was observed. In the case of annealed sample over $450^{\circ}C$ donor and acceptor impurities related peaks were observed which seems to be due to a diffusion of Ga and As from GaAs substrate. And also interdiffusion phenomena is idenified by the results of DCX measurements and which are consisten with the PL measurements.

  • PDF

The Measurement of Helper's Exposure Dose of nearby Radiographic Table in X-ray Examination (X선 촬영시 테이블 주변 촬영도움자의 피폭선량 측정)

  • Eun, Sung-Jong;Kim, Sung-Gil;Min, Byung-Woon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.415-420
    • /
    • 2011
  • The purpose of this study is to know the exposure dose nearby table on the general radiography(skull AP, chest PA, abdomen AP, lumbar lateral, hip joint, knee joint) and to find the reducing it. We measured beside the 45cm and 75cm table center, and 70cm, 80cm, 130cm, 150cm height from the bottom. That were measured highly from the radiography of lumbar lateral, abdomen AP and hip joint as followed $66.21{\mu}Sv$, $34.22{\mu}Sv$, and $32.35{\mu}Sv$ at the 80cm height beside 45cm from the center of table. Measured doses were reduced in order of chest PA, abdomen, hipjoint, skull, knee joint projection. It appears exposure dose of nearby radiographic table was extremely low amount compared with limit of dose(1mSv). If it protected by Pb apron, exposure dose of assisting person will not be exceed a limit of dose. Conclusively, Wearing apron is very important to avoid radiation from the general radiography.