• Title/Summary/Keyword: X선 발생장치

Search Result 85, Processing Time 0.024 seconds

Analysis of the Spatial Dose Rates According to the Type of Radiation Source Used in Multi-bed Hospital Room (다인병실에서 이용되는 방사선원의 종류에 따른 공간선량률 분석)

  • Jang, Dong-Gun;Kim, Junghoon;Park, Eun-Tae
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.407-413
    • /
    • 2017
  • Medical radiation offers significant benefits in diagnosing and treating patients, but it also generates unnecessary radiation exposure to those nearby. Accordingly, the objective of the present study was to analyze spatial dose rate according to types of radiation source term in multi-bed hospital rooms occupied by patients and general public. MCNPX was used for geometric simulation of multi-bed hospital rooms and radiation source terms, while the radiation source terms were established as whole body bone scan patients and imaging using a portable X-ray generator. The results of simulation on whole body bone scan patients showed $3.46{\mu}Sv/hr$ to another patient position, while experimental results on imaging using a portable X-ray generator showed $1.47{\times}10^{-8}{\mu}Sv/irradiation$ to another patient position in chest imaging and $2.97{\times}10^{-8}{\mu}Sv/irradiation$ to another patient position in abdomen imaging. Multi-bed hospital room, unnecessary radiation generated in the surrounding patients, while legal regulations and systematic measures are needed for radiation exposure in multi-bed hospital rooms that are currently lacking in Korea.

The New Type Pulse Generator Adopted Cascading Technique (소형트랜스의 Cascading 방식을 적용한 임펄스 출력특성)

  • Kyung-Ae Shin;Whi-Young kim;Myeong-Soon Kim
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.3
    • /
    • pp.363-368
    • /
    • 2001
  • This paper introduced cascading technique as a new technology composed of two pulse transformers and presented the experimental data and results. To obtain the stable pulse voltage adopted cascading technique, we designed and tested a compact pulse generator by adjusting the load resistors and input voltage. Adopting cascading technique to load, we found that average cascading voltage was about 62$\%$ of theoretical value. Cascading ratio was calculated at almost 19 compared with non cascading voltage.

  • PDF

A Study on the Reduction of Scattered Ray in Outside Radiation Field (조사야 외부의 산란선량 감소 방법에 관한 연구)

  • Je, Jaeyong;Jang, Howon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.539-543
    • /
    • 2016
  • In this research, The way to decrease a patient's exposure dose by reducing the scattered radiation dosage outside a radiation field with an diagnosis X-ray was examined. The scattered radiation dosage reaching other parts outside the radiation field was to be reduced by attaching a self-produced $150{\times}190mm^2$ lead plate to the lower part of a collimator. When a lead plate was inserted additionally and the scattered radiation dosage of the X axis was measured in the direction of the central X-ray axis, It was found out to have been decreased by 26 to 36%, and in the direction of Y axis, which was vertical direction from the central axis, The scattered radiation dosage depending on whether a lead plate was used or not displayed no large differences. These results shows that the impact of the scattered radiation by the off focus X-ray that was generated around the focus was bigger than that generated by the shutter of the collimator. Therefore it has been concluded that installing an additional lead plate in the lower part of the existing collimator can decrease the scattered radiation dosage outside a radiation field.

Experimental study for the irradiation effect of x-ray on the hatching process of fertilized eggs (X선 조사가 닭 유정란 부화과정에 미치는 영향)

  • Jeon, Byeong-Kyou;Yeo, Jin-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6413-6419
    • /
    • 2013
  • This study examined the irradiation effect of high energy x-rays on the hatching process of fertilized eggs, particularly with regard to malformation and blood cells change. The experimental groups were five day old fertilized eggs irradiated with x rays at doses of 5, 7.5, 10 Gyusing alinear accelerator. The control group was not irradiated. After three weeks, hatched chicks were sacrificed and examined for blood sampling. The survival rate of the x-ray irradiated groups were significantly lower than that of the control group (46.7vs 80%). The malformation rate of the experimental groups was60%, whereas no congenital malformations were observed in the control group. The experimental groups had a significantly higher malformation rate. The types of malformation were left wing defect, proptosis, microcephaly, cervical spine, and feet anomaly. The incidence of malformation increased with increasing radiation dose. The white blood cell count of control group and eachexperimental groups (5 and 7.5 Gy) were 87.64, 100.76 and 81.42 ($10^3/{\mu}L$), respectively. X-ray irradiation of 5 day old chick embryos increased the rate of death and malformation significantly.The malformations were estimated to have occurred by chromosomal abnormalities. Further genetic studies will be needed to confirm the correlation between high energy X-rays and the cause of malformations.

Development of Radiation Restrictor for Secondary Radiation Shielding of Mobile X-ray Generator (이동형 X선 발생장치의 2차 방사선 차폐를 위한 선속조절기 개발 연구)

  • Koo, Bon-Yeoul;Kim, Gha-Jung
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.397-403
    • /
    • 2018
  • Mobile X-ray generators are used not in the radiation area but in open space, which causes the exposure of secondary radiation to the healthcare professionals, patients, guardians, etc., regardless of their intentions. This study aimed to investigate the shielding effect of the developed radiation restrictor to block the secondary radiation scattered during the use of mobile X-ray generator. Upon setting the condition of mobile X-ray generator with chest AP, spatial doses were measured by the existence of human equivalent phantom and radiation restrictor, and measured by the existences of phantom and radiation restrictor at the same length of 100 cm. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from $-90^{\circ}$ (head direction) to $+90^{\circ}$ (body direction). Upon the study results, spatial doses in all direction were increased by 45% on average when using phantom in the same condition, however, they were decreased by 64% on average when using the developed radiation restrictor. The dose at 100 cm from the center of X-ray was $3.0{\pm}0.08{\mu}Gy$ without phantom and was increased by 40% with $4.2{\pm}0.08{\mu}Gy$ after phantom usage. The dose when using phantom and the developed radiation restrictor was $1.4{\pm}0.08{\mu}Gy$, which was decreased by 66% compared to the case without using them. Therefore, it is considered the scattered radiation can be shielded at 100-150 cm, the regulation of the distance between beds, effectively with the developed radiation restrictor when using mobile X-ray generators, which can lower the radiation exposure to the people nearby including healthcare professionals and patients.

Study on the Exposure Field of Head and Neck with Measurement of X-ray dose Distribution for Dental Panoramic X-ray System (치과 파노라마 장치의 X선 공간선량분포 측정을 통한 두경부 피폭영역 조사에 대한 연구)

  • Oh, Yoonjin;Hong, Girang;Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.17-21
    • /
    • 2015
  • Recently, As people's interest in the health of teeth is increased in the medical field changed into aging society, the number of times for the radiological diagnosis is increased. It can be said that the radiation exposure dose of Korean population is increased. It is also growing concern about radiation exposure. Therefore, the basic data for the dental panoramic X-ray system, its investigation and measuring the radiation dose is needed. In this study, we used ALOKA PDM-117 dosimeter and estimated a two-dimensional dose distribution of the dental panoramic X-ray system (VATEC Pax-400). Dose evaluation about the distribution is confirmed from the point of radiation exposure of a patient. Dose distribution of the dental panoramic X-ray system irradiated chin and the facial region to high dose as well as the parts of teeth. It was founded that the eye lens which are sensitive to radiation are exposed to unnecessary radiation, considering the effect of scattered radiation. The results of this study will be used more accurate dose assessment in a variety of object size and location of measuring dose.

Assessment of Spatial Dose Distribution in the Diagnostic Imaging Laboratory by Monte Carlo Simulation (몬테카를로 전산해석에 의한 X선 실습실의 공간선량분포 평가)

  • Cho, Yun-Hyeong;Kang, Bo Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.423-428
    • /
    • 2017
  • In this study, the calculation of the effective spatial dose distribution of the diagnostic imaging laboratory of K university was performed by the Monte Carlo simulation. The radiation generator has a maximum tube voltage of 150 kVp and a maximum current of 700 mA. Using the results, we compared the spatial effective dose distributions of diagnostic imaging laboratory when the shielding door was closed and opened. In conclusion, it was found that the effective dose in the operating room of the diagnostic imaging laboratory does not exceed the annual dose limit (6 mSv/y) of the student (occasional visitor) even when the door is opened. However, since the effective dose when the door is open is about 16 times higher in front of the lead glass window and about 3,000 times higher in front of the doorway than the case when the door is closed, closing the shielding door at the time of the practical exercising reduces unnecessary radiation exposure by great extent.

A Study on the Fabrication of bone Model X-ray Phantom Using CT Data and 3D Printing Technology (CT 데이터와 3D 프린팅 기술을 이용한 뼈 모형 X선 팬텀 제작에 관한 연구)

  • Yun, Myeong Seong;Han, Dong-Kyoon;Kim, Yeon-Min;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.879-886
    • /
    • 2018
  • A 3-dimensional (D) printer is a device capable of outputting a three-dimensional solid object based on data modeled in a computer. These features are utilized in the bone model X - ray phantom production etc using CT data by fusing with the radiation science field. A bone model phantom was made using data obtained by CT scan of an existing Pelvis phantom, using PLA, Wood, XT-CF20, Glow fill, Steel filaments which are materials of Fused Filament Fabrication (FFF) 3D printer.Measure Hounsfield Unit (HU) with images obtained by CT scan of the existing Pelvis phantom and five material phantoms made with 3D printer under the same conditions,SI and SNR were measured using a diagnostic X-ray generator, and each phantom was compared and analyzed.As a result, the X - ray phantom in the X - ray examination condition of the limb was found to be most suitable for the glow fill filament.The characteristics of the filament can be known to the base of this research and the practicality of X - ray phantom fabrication was confirmed.

Spatial Dose Distribution for Diagnostic X-ray Examination within X-ray Room using the MCNPX Program (MCNPX 프로그램을 통한 일반 X선 검사 시 검사실 내 공간선량분포)

  • Lee, Dong-yeon;Lee, Jin-soo
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.298-306
    • /
    • 2015
  • This study is the material of the additional filter(Cu, Ni, CaWO4, Gd+Ba) being used when the diagnosis X-ray was varied to evaluate the spatial dose distribution accordingly. And it suggest to find a suitable material. Experiments using MCNPX program based on the Monte Carlo simulation method was carried out by selecting the chest and abdomen taken. As a result, each material per dose, the average scatter dose is approximately 62%, 100 cm radius of the point of the simulated body surface exposure dose and 50 cm radius centered on the point average about 47%. It is determined that an Al material is currently available in accordance with the result to be replaced by Cu, Ni material is sufficient. With just the thickness due to the difference in the atomic number and density adjusted to be about one-tenth of the Al it will be suitable.

A Basic Study on Comparative Analysis with Bone using 3D Printer Filament Material (3D 프린터 필라멘트 재료를 이용한 뼈와의 비교분석에 관한 기초연구)

  • Kyung-Tae, Kwon;Hui-Min, Jang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.825-833
    • /
    • 2022
  • In 3D printing technology, materials that can be printed are increasing along with the development of material engineering, and materials that can be used in the field of radiation are also increasing. Therefore, depending on the composition and density of the materials used, the applied field can be different and applied, so the composition and characteristics of the materials must also be considered. In this study, 10 filaments with different properties were selected using a 3D printer of the FDM (Fused Deposition Modeling) method, and the brightness change of each filament was checked using a diagnostic X-ray generator, and the CT number was measured through CT. I wanted to find a material similar to bone. As a result, a material called silicon carbide was found, which has a similar brightness and CT number to bone. It is thought that further research will be presented as basic data for various studies with a density similar to that of human bones.