Browse > Article
http://dx.doi.org/10.7742/jksr.2016.10.7.539

A Study on the Reduction of Scattered Ray in Outside Radiation Field  

Je, Jaeyong (Department of Radiological Technology, Dong-Eui Institute of Technology)
Jang, Howon (Department of LED Convergence Engineering, Specialized Graduate School & Technology Convergence, Pukyong National University)
Publication Information
Journal of the Korean Society of Radiology / v.10, no.7, 2016 , pp. 539-543 More about this Journal
Abstract
In this research, The way to decrease a patient's exposure dose by reducing the scattered radiation dosage outside a radiation field with an diagnosis X-ray was examined. The scattered radiation dosage reaching other parts outside the radiation field was to be reduced by attaching a self-produced $150{\times}190mm^2$ lead plate to the lower part of a collimator. When a lead plate was inserted additionally and the scattered radiation dosage of the X axis was measured in the direction of the central X-ray axis, It was found out to have been decreased by 26 to 36%, and in the direction of Y axis, which was vertical direction from the central axis, The scattered radiation dosage depending on whether a lead plate was used or not displayed no large differences. These results shows that the impact of the scattered radiation by the off focus X-ray that was generated around the focus was bigger than that generated by the shutter of the collimator. Therefore it has been concluded that installing an additional lead plate in the lower part of the existing collimator can decrease the scattered radiation dosage outside a radiation field.
Keywords
collimator; scattered radiation; lead plate;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 J. J. Han and S. K. Kim, "An Analysis of the Radiation Exposure of Radiologic Technologists in the Field of Diagnostic Radiology according to Duty Station", Korean Association for Radiation Protection, Vol. 20, No. 1, pp. 71-75, 1997.
2 H. Y. Ha, "A Study for Reduction of Radiation Dose in the Field of Diagnostic Radiology" - A Point Tube Voltage and Filtration, Korean Association for Radiation Protection, Vol. 15, No. 1, pp. 89-97, 1992.
3 S. J. Eun, S. G. Kim, B. W. Min, "The Measurement of Helper's Exposure Dose of nearby Radiographic Table in X-ray Examination", Journal of the Korean Society of Radiology, Vol. 5, No. 6, pp. 415-420, 2011.   DOI
4 P. K. Cho, "Distribution of the Scatter Ray on Chest X-ray Examinations", The Journal of the Korea Contents Association, Vol. 12, No. 7, pp. 255-260, 2012.   DOI
5 S. K. Na, S. H. Han, “A Study on the Factors of Spatial Scattered Ray Occurrence in the X-ray Radiography Room,” Journal of radiological science and technology, Vol. 32, No. 4, pp. 393-399, 2009.
6 W. R. Hendee, "Real and Perceived Risks of Medical Radiation Exposure", Western Journal of Medicine, Vol. 138, No. 3, pp. 380-386, 1983.
7 S. S. Kang, et. al, Radiation Equipment, 3nd Ed., Chung Ku Pub., pp. 81, 2015.