• Title/Summary/Keyword: X선조사야

Search Result 478, Processing Time 0.031 seconds

The Radioprotection Effect of Aronia on Livers of Laboratory Rats Radiated to 6 MV X-ray of Linear Accelerator (선형가속기 6 MV X선에 조사된 흰쥐의 간에서 아로니아의 방사선 방호효과)

  • Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.97-104
    • /
    • 2020
  • This aimed at figuring out if there were the radioprotection effects of aronia on livers of laboratory rats radiated through serum test. For the objects of animal testing, one group consists of five male laboratory rats (weight 200~250 g), and the groups were set as follows: Group 1, normal; Group 2, 5 Gy radiated control group; and Group 3, 5 Gy radiated experiment group with aronia. Group 1(A) was prescribed with ordinary meal without radiation while the control group, Group 2(B) was prescribed with ordinary meal and radiation, and the experiment group, Group 3(C) was orally prescribed with aronia (daily oral dosage: 100 mg/kg/day) diluted with distilled water at the amount of 50 mg/kg/day twice a week, using oral zonde needle for rats for 14 days before being radiated, and then, radiation were made on them. For the study, using Linac (Linear Accelerator) 6 MV X-ray therapy device, rats were irradiated on their whole bodies once, and their blood was sampled for conducting five blood serum tests with regard to liver. For statistical analysis, ANOVA test was conducted. In conclusion, as a result of the analysis, it seemed that there were no the radioprotection effects of aronia on liver. However, it was confirmed statistically that ALB (P>0.05) showed no significance and that TP (P<0.05) showed significant differences. It is expected that there should be more tests in future.

Survey of Technical Parameters for Pediatric Chest X-ray Imaging by Using Effective DQE and Dose (유효검출양자효율과 선량을 이용한 소아 흉부 X-선 영상의 기술적인 인자에 관한 조사)

  • Park, Hye-Suk;Kim, Ye-Seul;Kim, Sang-Tae;Park, Ok-Seob;Jeon, Chang-Woo;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.163-171
    • /
    • 2011
  • The purpose of this study was to investigate the effect of various technical parameters for the dose optimization in pediatric chest radiological examinations by evaluating effective dose and effective detective quantum efficiency (eDQE) including the scatter radiation from the object, the blur caused by the focal spot, geometric magnification and detector characteristics. For the tube voltages ranging from 40 to 90 kVp in 10 kVp increments at the FDD of 100, 110, 120, 150, 180 cm, the eDQE was evaluated at the same effective dose. The results showed that the eDQE was largest at 60 kVp when compares the eDQE at different tube voltage. Especially, the eDQE was considerably higher without the use of an anti-scatter grid on equivalent effective dose. This indicates that the reducing the scatter radiation did not compensate for the loss of absorbed effective photons in the grid. When the grid is not used the eDQE increased with increasing FDD because of the greater effective modulation transfer function (eMTF). However, most of major hospitals in Korea employed a short FDD of 100 cm with an anti-scatter grid for the chest radiological examination of a 15 month old infant. As a result, the entrance surface air kerma (ESAK) values for the hospitals of this survey exceeded the Korean DRL (diagnostic reference level) of $100{\mu}Gy$. Therefore, appropriate technical parameters should be established to perform pediatric chest examinations on children of different ages. The results of this study may serve as a baseline to establish detailed reference level of pediatric dose for different ages.

The Effect of Crystal Structure on the Piezoelectric Properties of PVDF Film (PVDF의 결정구조가 압전특성에 미치는 영향)

  • 이덕출;박강식
    • Electrical & Electronic Materials
    • /
    • v.2 no.2
    • /
    • pp.127-136
    • /
    • 1989
  • PVDF 필름의 압전성과 결정구조와의 관계를 조사하기 위하여 X선 회절과 압전계수를 측정하였다. 코로나 분극처리된 PVDF의 압전계수는 분극전압에 비례하여 증가하고 결정구조도 .alpha.형, 극성.alpha.형, .betha.형의 순으로 변화하였다. 이와같은 결과로부터 PVDF의 압전특성은 결정영역내의 쌍극자 배향에 의한 결정구조변화에 기인됨을 알 수 있었다.

  • PDF

Cation Ordering and Microwave Dielectric Properties of Complex Perovskite Compounds $La(Mg_{1/2}Ti_{1/2})O_3$ and $La(Mg_{1/2}Zr){1/2})O_3$ ($La(Mg_{1/2}Ti_{1/2})O_3$$La(Mg_{1/2}Zr){1/2})O_3$에서의 양이온 규칙과 고주파 유전특성)

  • 조서용;고경현;홍국선;박순자
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.3
    • /
    • pp.330-336
    • /
    • 1997
  • 1:1 복합 페로스카이트 물질인 La(Mg1/2Ti1/2)O3 and La(Mg1/2Zr1/2)O3의 양이온 규칙 존재와 고주파 유전특성을 x선 회절과 회로망분석기를 사용하여 조사하였다. 기존의 연구에서는 두 물질 모두 양이온 규칙이 없으며 입방정 구조를 갖는다고 보고되었지만, 본 연구에서의 x선 분석에서는 양이온 규칙을 나타내는 초격자회절선과 비입방정 구조를 의미하는 기본회절선의 split이 발견되었다. 고주파 영역에서의 유전율은 La(Mg1/2Ti1/2)O3의 경우 29,La(Mg1/2Zr1/2)O3는 24, 품질계수(Q*f)는 각각 73000, 49000이다. 공진주파수 온도계수는 La(Mg1/2Ti1/2)O3의 경우 - 65ppm/$^{\circ}$C,La(Mg1/2Zr1/2)O3는 -80ppm/$^{\circ}$C로 음의 값을 가진다.

  • PDF

High Voltage Resonant DC-DC Converter Design for X-Ray Imaging (X-Ray 진찰용 고전압 공진형 DC-DC 컨버터 설계)

  • Baek, Jong-Mu;Joo, Hae-Jong;Cho, Moon-Taek;Lee, Chung-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.4
    • /
    • pp.11-16
    • /
    • 2010
  • In this paper, including the X-ray high voltage resonant inverter generators and high frequency high voltage transformer operating systems is proposed. X-ray generator removes the noise and was smaller, 50[kHz] to work more with the driving frequencies, and that occurred when the normal power supply available due to noise, survey the conditions and solve the problems of the poor was a problem. In addition, X-ray tube voltage, frequency controllers and tube current controller filament heating voltage transformer for high frequency transformer design and manufacture of doing X-ray devices were to become more efficient operation.

Small Angle X-Ray Scattering Study on the Oxopolymer Variations of BaTi-ethoxide Sol by Catalysts (촉매제에 의한 BaTi-에톡사이드 솔의 옥소폴리머 변화에 대한 저각 X선 산란연구)

  • 고태경;배호기
    • Korean Journal of Crystallography
    • /
    • v.4 no.1
    • /
    • pp.36-41
    • /
    • 1993
  • Small angle X-ray scattering was used to study on the oxopolymers of sols derived from BaTiethoxide. The growths of the oxopolymers in tools obtained with NH40H as catalyst and catalystfree sol are similar. Their radii of gyration are 1.66-2.08nm. They exhibit a mass fractal behavior with a dimension of 1.6, which is almost inde pendent with amount of NH40H addition. Sols catalyzed with CHSCOOH have greater radii of gyration of 3.24-4.OOnm. Their scattering curves are similar in the intermediate Q region, showing a mass fractal dimension of 1.8. The oxopolymers of the tools from the base and the neutral hydrolysis conditions may have a short chain structure.

  • PDF

EFFECT OF X-RAY IRRADIATION ON THE DENTIN MATRIX FORMATION (X선조사가 상아기질성형에 미치는 영향)

  • You Dong Soo;Change Wan Shik;Hwang Sung Myung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.6 no.1
    • /
    • pp.15-18
    • /
    • 1976
  • The authors has observed the effect of X-ray irradiation on the dentin matrix formation of the albino rat fetuses. The lower abdomen of the pregnant ratswere exposed to X-ray on the 9 1/2th day of gestation, respectively 150, 250 and 350 rads. The fetuses of the right sides of the same pregnant rats which were not exposed to X-ray were as controls. The results were as follows: 1) In the 150 rads irradiated fetuses, predentin formation was identical with control groups, but the arrangement of odontoblasts was distorted, subodontoblastic layer was condesed with pulp cells and blood capillaries were enlarged. 2) In the 250 rads irradiation, dentin matrix was imperfact or osteodentin was occured. Short columnar or cuboidal odontoblasts were presented and pulp cells were dispersed. Blood capillaries were cogested. 3) 350 rads irradiated fetuses showed osteodentin matrix and numerous degenerated odontoblasts. Their dental papilla showed reticular atrophy and enlarged capillary.

  • PDF

EXPERIMENTAL STUDY ON THE EFFECT OF X-IRRADIATION IN THE RAT PERIODONTAL LIGAMENT (X선조사가 발육치근막에 미치는 영향에 관한 실험적 연구)

  • Cho Won Pyo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.10 no.1
    • /
    • pp.9-14
    • /
    • 1980
  • The author studied on the effects of X-ray irradiation to the development of periodontal ligament in gestation rats. They were irradiated in their abdomen with 100, 200 and 300 rads respectively in one shot irradiation with deep radiation therapy equipment (MAXIMAR 250-Ⅲ), In 7th, 14th, 21th and 28th day after delivery, those new born rats were respectively sacrificed with ether anesthesia and removed of their mandibles. After removal, those mandibles were fixed in 10% neutral buffer formalin, decalcified with 5% trichloroacetic acid for 5 days and embedded with paraffine. Staining was performed with H-E, Van Gieson, Mallory azan, Bielshowsky-Gomori silver stain and Halmi's oxytalan fiber stain. The results were as follows: 1. Before tooth eruption, all the fiber: components in dental sac were almost always oriented near the outer enamel epithelial \layer. But in irradiated new born rats, those collagen fiber orientation was more irregular than those of control groups, and this phenomenon was more severe in proportion to the amount of irradiation in the gestation period. 2. Before tooth eruption, the connective tissue fibers in periodontal ligament were stained with lighter in the irradiated groups than those of control groups. Oxytalan fibers of irradiated groups were thin and splitting pattern of their fiber morphology to compare with those of control groups. 3. After tooth eruption, the periodontal ligament fibers of irradiated groups were oriented functionally and their morphology was thick, fine and heavy staining. Oxytalan fibers were revealed with oblique parallel arrangement in the periodontal ligament of irradiated groups.

  • PDF