• 제목/요약/키워드: Wrist Band

Search Result 42, Processing Time 0.031 seconds

Comparison of Pain, Sense, Bleeding and Hematoma Depending on the Process of Air Elimination of Pressure Band after Percutaneous Coronary Intervention through Radial Artery (요골동맥을 통한 경피적 관상동맥 중재술 후 압박밴드의 공기제거 방법에 따른 통증 강도, 통증 감각, 출혈 및 혈종 비교)

  • Kim, Mi Seok;Oh, Ji Seon;Cho, Hye Young
    • Journal of Korean Clinical Nursing Research
    • /
    • v.18 no.2
    • /
    • pp.275-283
    • /
    • 2012
  • Purpose: This study was conducted to compare pain, sense, bleeding, and hematoma that patients feel depending on the process of eliminating air of pressure band that was applied to patients after percutaneous coronary intervention (PCI) through radial artery. Methods: It was a nonequivalent control group pretestposttest design to compare pain, sense, bleeding, and hematoma by amount and time of eliminating air of pressure band after PCI through radial artery. Results: On arrival at Coronary Care Unit, meaningful difference didn't exist between pain and sense, however, after two hours of starting eliminating air, the points of pain and sense were meaningfully low (p<.001). Also, there was meaningful difference in reciprocal action between group and time (p<.001). Conclusion: After PCI, the conclusion showed there is positive effect in decreasing wrist pain and sense without any influence of bleeding by eliminating air from patients' pressure bands.

Effects of Functional Electrical Stimulation Intensity Level on Corticomuscular Coherence during Action Observation

  • Kim, Ji Young;Noh, Hyunju;Park, Jiwon
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.5
    • /
    • pp.307-311
    • /
    • 2020
  • Purpose: This study examined the effects of changes in the intensity of Functional Electrical Stimulation (FES) on CorticoMuscular Coherence (CMC) during action observation. This paper presents a neurophysiological basis for the effective intensity of FES. Methods: Twenty-seven healthy volunteers were asked to observed a video with FES. The FES was provided with a sensory stimulation level, nerve stimulation level, and motor stimulation level. Simultaneously, an electroencephalogram (EEG) of the sensorimotor cortex and electromyogram (EMG) from the wrist extensor muscle were recorded. The peak CMC and average CMC were analyzed to compare the differences caused by the FES intensity. Results: The peak CMC showed a significant increase in the alpha band during motor stimulation (p<0.05). The average CMC showed a significant increase in the beta band during motor stimulation (p<0.05). Conclusion: The intensity of FES, which causes actual movement, increased the CMC during action observation. These results show that the intensity of the FES can affect the functional connection between the sensorimotor cortex and muscle.

The Important Frequency Band Selection and Feature Vecotor Extraction System by an Evolutional Method

  • Yazama, Yuuki;Mitsukura, Yasue;Fukumi, Minoru;Akamatsu, Norio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2209-2212
    • /
    • 2003
  • In this paper, we propose the method to extract the important frequency bands from the EMG signal, and for generation of feature vector using the important frequency bands. The EMG signal is measured with 4 sensor and is recorded as 4 channel’s time series data. The same frequency bands from 4 channel’s frequency components are selected as the important frequency bands. The feature vector is calculated by the function formed using the combination of selected same important frequency bands. The EMG signals acquired from seven wrist motion type are recognized by changing into the feature vector formed. Then, the extraction and generation is performed by using the double combination of the genetic algorithm (GA) and the neural network (NN). Finally, in order to illustrate the effectiveness of the proposed method, computer simulations are done.

  • PDF

A Study of the Effects of Wearing Gloves on Grip Strength and Safety (장갑 착용이 악력과 안전에 미치는 영향에 관한 연구)

  • Jung, Hwa-Shik;Koo, Dong-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.4
    • /
    • pp.13-23
    • /
    • 2006
  • Grip strength provides a quick and objective index of the functional integrity of the upper extremities. It is widely used as an assessment measure in physical and rehabilitation medicine. In this study, maximum voluntary grip strength of 20 college students wearing 5 different gloves were measured using Jamar hand dynamometer. The results show that maximum voluntary grip strength was generally reduced when wearing gloves as compared to bare-handed. More specifically, the grip strength was highest when wearing PVC coated glove or bare-handed and getting lowered as wrist band, rubber, leather, and cotton glove in these order. Depending on the measuring posture of grip strength, shoulder height with arm extended forward was higher than the elbow was flexed 90 degree. Moreover, subjects' demographic factors and hand dimensions were not closely related to the grip strength. It is thus recommended that the proper glove should be provided to reduce the negative consequences including dropping a tool, poorer control of a tool. lower quality work, and increased muscle fatigue and in turn to increase the user safety and satisfaction.

Voice-based Device Control Using oneM2M IoT Platforms

  • Jeong, Isu;Yun, Jaeseok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.3
    • /
    • pp.151-157
    • /
    • 2019
  • In this paper, we present a prototype system for controlling IoT home appliances via voice-based commands. A voice command has been widely deployed as one of unobtrusive user interfaces for applications in a variety of IoT domains. However, interoperability between diverse IoT systems is limited by several dominant companies providing voice assistants like Amazon Alexa or Google Now due to their proprietary systems. A global IoT standard, oneM2M has been proposed to mitigate the lack of interoperability between IoT systems. In this paper, we deployed oneM2M-based platforms for a voice record device like a wrist band and LED control device like a home appliance. We developed all the components for recording voices and controlling IoT devices, and demonstrate the feasibility of our proposed method based on oneM2M platforms and Google STT (Speech-to-Text) API for controlling home appliances by showing a user scenario for turning the LED device on and off via voice commands.

Effect of Acupuncture at the LU5(Reinforcement), LU10(Reduction) on the Pulsation Scale of Chon, Gwan and Chuk region using High Resolution Infrared Camera (척택.어제 침자가 고해상도 적외선 카메라로 관찰한 촌구맥 부위의 온도 Pulsation 변화에 미치는 영향 연구)

  • Na, Chang-Su;Jeon, Hyo-Sang;Kim, Jee-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.127-133
    • /
    • 2011
  • Arteria radialis is a branch of the brachial artery extending down the forearm around the wrist where it closes to skin surface. In the oriental medicine, the skin above arteria radialis has an important role because oriental medicine practitioners put their finger tips on the area, and diagnose patient's health conditions by feeling the pulsation of the arterial contraction. The finger tip diagnostic method relies on subjective decision of the practitioner; and there is a need to develop an objective diagnostic modality. The pulsation of the arterial contraction appears not only a movement on the site but also as temperature fluctuation due to pulsatile feeding of warmer blood. The goal of this study is to demonstrate a feasibility of using an infrared camera quantitatively to detect the temperature fluctuation on the skin. Clinical important three different areas, called chon, gwan, chuk, near a wrist where the arteria radialis reaches close to skin surface are marked with small pieces of surgical tape. A high-speed and high-resolution infrared camera with a 3 cm of field of view measures these areas for 10 second at 200 frames per second with a 320*240 pixel size. The pulsatile temperature fluctuation is calculated after passing a band pass filter to remove any stationary temperature over 10 second. The temperature fluctuation of a healthy male volunteer is measured at a room temperature as a control, and is compared with another measurement performed after 20 minutes staying in a room at a 40 degree Celsius. This comparison is repeated for three times, and indicates that the fluctuation increases after staying 20 minutes in the warm room. This increase becomes smaller when the person stays in the warm room with an acupuncture treatment that decreases body temperature. So that an objective diagnostics on the site may become feasible.

Measurement of Arterial Pulse Wave at the Temple Using PZT Piezo Sensor

  • Kil Se Kee;Han Young Hwan;Lee Eung Hyuk;Park Young Bae;Cho Heung Ho;Min Hong Ki;Hong Seung Hong
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.772-775
    • /
    • 2004
  • Generally, arterial pulse waves are measured at the radial arterial of wrist or carotid arterial of neck using a sensor such as pressure sensor, piezoelectric sensor or optic sensor. But in this paper, arterial pulse wave is measured at the temple using PZT piezo sensor which is attached on the temple in form of a hair-band. Arterial Pulse waves are generally measured when a reagent is in a static state. But in this paper, we implemented the arterial pulse wave measurement system, as a previous stage of the arterial pulse wave measurement system for running at outdoors or on a running machine, that measures arterial pulse waves at the temple, which is the least moving part when running. Thorough the continuous study, if the motion artifact when running is possible to be removed, the system will be able to perform monitoring of running men's states and especially emergency signals such as serious pulse waves of an/old and feeble persons and handicapped persons.

  • PDF

A Study on the Satisfaction of Working Uniform on Nuclear Power Plant (원자력 발전소 작업복의 착용만족도에 관한 연구)

  • Kim, Younghee;Cho, Kyungsook
    • Fashion & Textile Research Journal
    • /
    • v.18 no.5
    • /
    • pp.668-676
    • /
    • 2016
  • The purposes of this study were to investigate the satisfaction of working uniform in Nuclear Power Plant and to suggest the improvement of dissatisfaction. 150 workers in control area of Nuclear Power Plant were participated in survey and 30 questionnaires were asked and subjective description was allowed. 65%/35% Poly/Rayon coverall type working uniform was investigated for this survey which had been wearing usually and basically in control area in Nuclear Power Plant. According to the results, respondents were most highly dissatisfied with the wearing convenience aspect of current coverall among any other aspects, like textile and management. In wearing convenience aspects, wrist and ankle opening band system, the design, number and placement of pocket, waist belt design, the width of sleeve and pants, and ADR opening system were dissatisfied and requested for improvement. In textiles aspects, weight, protection from radiation materials, prevention from static electricity, moisture absorption, ventilation and flexibility/elasticity were dissatisfied and requested for improvement. In management aspect, washing uniform and size variation were dissatisfied and requested for improvement. Therefore, for more comfortable human interfaced working uniform, wearing convenience system as well as textile and management system must be compensated and should be newly developed for improving worker comfort, mobility, and productivity.

The Meta-Analysis of the Effect of Acupressure for Nausea and Vomiting in Cancer Patients Receiving Chemotherapy (지압이 항암요법환자의 오심과 구토에 미치는 효과 관련 연구 분석)

  • Jang, Soon-Yang;Park, Jeong-Sook
    • Asian Oncology Nursing
    • /
    • v.11 no.2
    • /
    • pp.116-126
    • /
    • 2011
  • Purpose: This study was to analyze the characteristics and effect size of intervention studies that used acupressure for the control of chemotherapy-induced nausea and vomiting (CINV). Methods: Nine electronic databases including Korea Education Research and Information, the National Assembly Library, KISS, Korea Med, NDSL, PubMed, EBSCO, Cochrane library, and OVID (to December, 2009) were searched. Thirteen studies of randomized controlled trials (RCTs) or controlled clinical trials (CCTs) were selected. Data were analyzed by SPSS/WIN 18.0. Results: Overall effect size of acupressure was moderate (0.684). Nausea had a moderate effect size (0.770) and nausea and vomiting had a high effect size (0.899). Acupressure using sticker needles had a high effect size (1.368) among finger acupressure, si-acupuncture, and wrist band treatment. Conclusion: This study suggests that acupressure using sticker needles on the spots of nei-guan, chok-samni and hap-kok can reduce the levels of nausea and vomiting in cancer patients receiving chemotherapy. For improving the reliability of the meta-analysis results, further randomized controlled trials with better study methodology are needed.

Automatic Detection and Analysis of Desktop Bus'(D-Bus) Privilege Bypass in Tizen (타이젠 용 데스크톱 버스 (D-Bus) 권한 우회 취약점 분석 및 자동 탐지)

  • Kim, Dongsung;Choi, Hyoung-Kee
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.30 no.6
    • /
    • pp.1023-1030
    • /
    • 2020
  • Wearable devices, such as a smart watch and a wrist band, store owner's private information in the devices so that security in a high level is required. Applications developed by third parties in Tizen request for an access to designated services through the desktop bus (D-Bus). The D-Bus verifies application's privileges to grant the request for an access. We developed a fuzzing tool, so-called DAN (the D-bus ANalyzer), to detect errors in implementations for privilege verifications and access controls within Tizen's system services. The DAN has found a number of vulnerable services which granted accesses to unauthorized applications. We built a proof-of-concept application based on those findings to demonstrate a bypass in the privilege examination.