• Title/Summary/Keyword: Workplane illuminance

Search Result 12, Processing Time 0.034 seconds

Development of Nomographs for the Evaluation of Lighting Energy Performance in a Semi-infinite Office Space (중규모 사무공간에서 조명에너지 성능평가를 위한 노모그래프 개발에 관한 연구)

  • Kim, Han-Seong;Ko, Dong-Hwan;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.73-80
    • /
    • 2003
  • The purpose of this study was to analyze daylighting performance in a semi-infinite size office space for lighting energy conservation. DOE2.1E was used for simulations for the model space of $12\times12\times2.6m$. Nomographs were developed which could simulate work plane illuminance, glare index, energy consumption rate and energy reduction rate for daylighting design. Major results of simulations are as follows ; 1) When blinds facing south were installed, 43% of workplane illuminance diminished, but the flare index didn't exceed the recommended max-glare value. 2) In a semi-infinite office space facing south. energy consumption rate in the case space of 500 lux workplane illuminance is larger then case space of 300 lux workplane illuminance. Therefore, energy reduction rate is increased when the semi-infinite office faces south and naintains 300 lux workplane illuminance level.

An experimental study of the optimum location and spatial characteristics of photosensor for the improvement of daylight responsive dimming system performance (광센서 조광제어시스템의 성능향상을 위한 광센서의 방향성에 관한 실험적 연구)

  • 정봉근;최안섭
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.87-90
    • /
    • 2002
  • Daylight responsive dimming system, which is always able to automatically maintain the target illuminance, is a energy strategic system. It is importance note that the photosensor depends how to be precisely indicated workplane illuminance at any location of indoor. Therefore, the purpose of this paper is to find out the optimum location and spatial characteristics of photosensor by considering the correlation for the correct calibration of workplane illuminance and photosensor signal.

  • PDF

Evaluation of Lighting Energy Saving Rate in a Small Office Space (소규모 사무공간의 조명에너지 절감율 평가에 관한 연구)

  • Kim, Han-Yong;Yun, Gyeong;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.50-58
    • /
    • 2012
  • The objective of this study is to evaluate the lighting dimming rates with various parameters of the building skin in a small office. We compared to simulated workplane illuminance and measured workplane illuminance for the base model. After that, the five veriables(the presence of vertical wall in double skin facade, the presence of windowsill, window to wall ratio(WWR), window visible transmittance, the width of double skin facade) were applied to base model, and we analyzed the simulated lighting energy saving rates. The results are listed as below. The simulated workplane illuminance results are similar to the measurement. Simulated illuminance was smaller than measured illuminance by 16.5%(60 lx). In accordance with applicable building skin parameters, lighting energy saving rate results are summarized as follows. Lighting energy saving rate of case1(windowsill height 0.7m) is higher than that of base case(windowsill and vertical wall) by 7.3% and the lighting energy saving rate of case2(no vertical wall) is higher than that of base case by 7.6% and the lighting energy saving rate of case3(no windowsill and vertical wall) is higher than that of base case by 12.4%. The lighting energy saving rate is increased by 2.3%, when window visible transmittance is increased from 70% to 86%. The lighting energy saving rate is increased by 4.6%, when we changed the WWR 70% to 90%. lighting energy savings rate is increased by 6.5%, when the width of double skin facade is reduced from 1m to 0.3m.

Optimum Control of a Photoelectric Dimming System in a Small Office with a Double Skin Envelope

  • Kim, Soo Young;Yum, Sung Kon
    • Architectural research
    • /
    • v.7 no.2
    • /
    • pp.47-54
    • /
    • 2005
  • A photoelectric dimming control system for a small private office space with a double skin envelope system was analyzed for the purpose of examining optimum control performances under a variety of daylight conditions. Computer simulations were performed for the three different photosensor types positioned at the center of ceiling in the space. They were applied in both a south and north-facing room. Daylight conditions were a fixed horizontal venetian blind on an external envelope and a retractable shading device on an internal envelope under a clear, intermediate and overcast sky at different times of a day and year. Partially-shielded photosensors provided good control performances providing the required electric light output under clear and intermediate sky conditions. Unshielded photosensors failed to provide necessary illuminance levels producing less electric output and fully-shielded photosensors generally provided excessive light output. Reasonable electric lighting energy savings were achieved except under overcast sky conditions where the control system did not contribute to energy savings due to the less daylight through envelopes. The retractable shading device covering 50% of the internal envelope reduced energy savings up to 19.62%, but the workplane illuminance levels were maintained within recommended ranges. The coefficients of determination between workplane illuminance and photosensor illuminance due to daylight ranged from 0.74 to 0.98. Partially-shielded conditions provided best correlations and the north-facing room yielded stronger correlation than the south-facing room.

A Study on lighting Energy Conservation in a Small Office Space with Daylight Dimming Control System (소규모 사무공간에서 디밍제어를 이용한 조명에너지 절약에 관한 연구)

  • 김한성;김강수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.15-21
    • /
    • 2003
  • This paper presents field measurements on daylighting and electric lighting with dimming controlled systems for a small office in Seoul, Korea. And the main purpose of this study is to provide the evaluation data of lighting energy performance when a dimming system is installed. For the performance evaluation, the mock-up room(3.6x7.2x2.6[m]) was used for the actual test. The results of this study were as follows; 1) The correlation between daylight illuminance at a workplane(Ed) and the photosensor signal(Sd) was an important factor affecting the performance of daylight responsive dimming system, 2) The mock-up office space gained a sufficient workplace illuminance of 579[lux] with the dimming control system 3) About 53[%J of monthly lighting energy could be saved using the dimming control system.

Characteristics of the Illuminance Distributions by Artificial Lighting in Different Shading Systems (쉐이딩 시스템에 따른 인공조명에 의한 조도분포 특성에 관한 연구)

  • Park, Byoung-Chul;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.169-172
    • /
    • 2009
  • Daylight responsive dimming system, which is one of the method for utilizing available daylight. continuously adjusts lighting output with an algorithm of the correlation of photosensor signal and workplane illuminance levels. This system must be related with shading systems which are to control penetrating daylight. The purpose of this research is to analyze illuminance distributions by artificial lighting in different shading systems. Lighting power is changed by 5 levels in nighttime for comparing correlation between illuminance and lighting power in different shading systems.

  • PDF

A Study on the Perception of the Brightness Change according to Daylight Responsive LED Dimming Systems and Venetian Blind (블라인드연동 LED조명의 조광제어에 따른 재실자의 밝기 변화 인식에 관한 연구)

  • Youm, Hyun-Ju;Kim, In-Tea;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.44-53
    • /
    • 2013
  • This study has attempted to investigate how subjects perceive changes of brightness and their visual comfort according to daylight responsive LED(Light Emitting Diode) dimming systems in the office with venetian blind. Two studies was conducted. First study is that how subjects perceive changes of brightness and their visual comfort depending on angle control method of the venetian blind while the workplane illuminance level is being maintained through daylight responsive LED dimming system. Second study is that how subjects perceive changes of brightness and their visual comfort depending on the amount of daylight penetrated into the building while the illuminance level is being maintained through daylight responsive LED dimming system. The results of this study could be proposed as basic data in the control of the venetian blind and LED lighting in consideration of their perception on changes of brightness and visual comfort.

A Computational Analysis on Candela Distribution Curves and Performance Prediction of a Fiber Optic Dish Daylighting System by Photopia (Photopia를 이용한 추적식 디쉬형 집광기의 배광분포 분석 및 자연채광 성능 예측)

  • Oh, Seung-Jin;Han, Hyun-Joo;Jeon, Young-Il;Chun, Won-Gee
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.104-113
    • /
    • 2012
  • A set of candela distribution curves(CDCs) were generated for a fiber optic dish daylighting system by Photopia under clear sky conditions at different solar altitudes. The candela distribution curves were then exported to Radiance for photometric analysis of a windowless lecture room. Observations were made on the Radiance rendered illuminance images, which provided photo realistic scenes varying with solar altitudes. If no tracking error were assumed, the daylight collection efficiency of the system remained at a constant value of 68.4% during its operation. Higher the solar altitude angle, greater in photometric quantities were observed, which are represented by candela(cd) and total lumens(lm). In all cases considered, however, the angle of light distribution remained fixed reflecting the solar tracking feature of the system. The illuminance uniformity on the workplane lingered around 0.12, which is quite low. This is quite a contrast to its average value of 0.68 of the $2.7m^2$ area directly below the terminal device (diffuser) of the system. The maximum illuminance of 1,340lux was obtained at a solar altitude of 80 degrees.

A Fundamental Study on the Changes of Coefficients of Utilization by Surface Reflectance and Photometry (공간 반사율 및 배광에 따른 이용률 변화에 관한 기초적 연구)

  • Kim, Yu-Sin;Park, Byoung-Chul;Jeong, Keun-Young;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.101-106
    • /
    • 2008
  • Zonal cavity method, which is a kind of the lumen method, is used the calculation of the average illuminance on the workplane in an interior. Important factors of the method are cavity ratio, coefficient of utilization, and light loss factor. A Coefficient of Utilization varies with a kind of luminaires and is affected by surface reflectance of space. For this, the data from Coefficient of Utilization computation were analyzed with the same lumens and different photometry. This paper analyzes the changes of Coefficients of Utilization on the photometry of luminaires and surface reflectance of space.

  • PDF

An Experimental Study on Control Strategy of LED System Using Daylight (주광을 활용한 LED조명시스템의 컨트롤에 관한 실험적 연구)

  • Yun, Gyeong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.33-39
    • /
    • 2010
  • Visual Environment and productivity are correlated. So we need to create a comfortable visual environment and maintain proper workplane illumination level. We can obtain lighting energy savings and comfortable visual environment using daylight and LED lights. In this study, we characterized the indoor illuminance level according to the sky condition and proposed dimming control strategy of LED lights. Energy savings in On/Off control mode are 40% at clear sky and 28% at intermediate sky. In dimming control mode, energy savings are 77.2% at clear sky and 64.1% at intermediate sky. Then we obtain the appropriate dimming control strategy of LED lights based on data. Dimming rates are 0-14.2-80(min-avg-max, %) for LED 1, 0-19.9-60% for LED 2 and 30-61.4-90% for LED 3. Lighting energy savings are 68.2% for LED dimming system applied this control method.