Abstract
The objective of this study is to evaluate the lighting dimming rates with various parameters of the building skin in a small office. We compared to simulated workplane illuminance and measured workplane illuminance for the base model. After that, the five veriables(the presence of vertical wall in double skin facade, the presence of windowsill, window to wall ratio(WWR), window visible transmittance, the width of double skin facade) were applied to base model, and we analyzed the simulated lighting energy saving rates. The results are listed as below. The simulated workplane illuminance results are similar to the measurement. Simulated illuminance was smaller than measured illuminance by 16.5%(60 lx). In accordance with applicable building skin parameters, lighting energy saving rate results are summarized as follows. Lighting energy saving rate of case1(windowsill height 0.7m) is higher than that of base case(windowsill and vertical wall) by 7.3% and the lighting energy saving rate of case2(no vertical wall) is higher than that of base case by 7.6% and the lighting energy saving rate of case3(no windowsill and vertical wall) is higher than that of base case by 12.4%. The lighting energy saving rate is increased by 2.3%, when window visible transmittance is increased from 70% to 86%. The lighting energy saving rate is increased by 4.6%, when we changed the WWR 70% to 90%. lighting energy savings rate is increased by 6.5%, when the width of double skin facade is reduced from 1m to 0.3m.
Keywords
Daysim; Lighting energy; illuminance measurement; Saving rate; Dimming Control;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Yun G, Yun KC, Kim KS, An Experimental Study on Control Strategy of LED System Using Daylight, Korea Institute of Ecological Architecture and Environment, Vol.10, Issue 6, pp. 30-40, 2010.12.
2 Kim HS, Kim KS, A Study on Lighting Energy Conservation in a Small Office Space with Daylight Dimming Control System, The Korean Institute of Illuminating and Electrical Installation Engineers, Vol.17, Issue.5, pp. 15-21, 2003.9.   DOI
3 Zack Rogers, David Goldman, Daylighting Metric Development Using Daylight Autonomy Calculations in the Sensor Placement Optimization Tool, DHPS Daylighting Committee Daylighting Forum, Architectural Energy Corporation, 2006.3.
4 Azza Nabil, John Mardaljevic, Useful Daylight Illuminances : A Replacement for Daylight Factors, Energy and Buildings, Vol.38, Issue 7, pp. 905-913, 2006.   DOI
5 Reinhart CF, Tutorial on the use of Daysim simulations for sustainable design, Harvard University, 2010.
6 Perez et al, Modeling daylight availability and irradiance components from direct and global irradiance, Solar Energy, Vol.44, Issue 5, pp. 271-289, 1990.   DOI
7 A.H. Fakra, A simple evaluation of global and diffuse luminous efficacy for all sky conditions in tropical and humid climate, Renewable Energy, Vol.36, Issue 1, pp. 298-306, 2011.   DOI