• Title/Summary/Keyword: Working Hour

Search Result 317, Processing Time 0.027 seconds

Development of a Belt Pick-up One-row Soybean Cutter (벨트 파지식 1조 콩 예취기 개발)

  • Jun, Hyeon-Jong;Kang, Tae-Gyoung;Lee, Choung-Keun;Choi, Yong;Lee, Chai-Sik;Hong, Jong-Tae
    • Journal of Biosystems Engineering
    • /
    • v.35 no.6
    • /
    • pp.373-379
    • /
    • 2010
  • This study was carried out to develop a belt pick-up type one-row soybean cutter, using physical properties and production conditions of soybeans. The prototype soybean cutter consisted of 4 parts: cutting part, conveying part, collecting part, and travelling part. The prototype soybean cutter was designed to cut soybeans planted with a row spacing of 600 mm, and at a height of 30 mm from the bed bottom using a disk saw. Through various trials with different peripheral velocities of the disk saw and forward speed of the cutter, determined ranges of the peripheral velocity of the disk saw cutting soybeans stems were greater than 18.3 m/s. Spacing between pick-up belts (clearance) was in a range of 60~90 mm so that soybeans could be picked at heights greater than 25 cm, and the size and shape of the pick-up belt were determined the conventional manual harvesting method. The optimal ratio between the forward speed of cutter and the peripheral speed of pick-up belts were from 1 to 1.2 by theoretical analysis. the pick-up belts had a $35^{\circ}$ of tilted angle and $90^{\circ}$ of twisted angle to pick up soybeans safely from the plant input to the lower end of the belts and convey soybeans to the upper end of belts nearby a container. The soybeans at the rear container were dropped down on the soybean row with an interval. The effective field capacity of the prototype soybean cutter was 0.136 ha/h, reducing the working hour by 92% when compared with the manual cutting.

Fatigue Symptoms and Its Related Factors among General Hospital Nurses (종합병원 간호사들의 피로수준 및 관련요인)

  • Park, An-Suk;Kwon, In-Sun;Cho, Young-Chae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.2164-2172
    • /
    • 2009
  • The purpose of the present study was intended to assess fatigue symptoms of nurses working at special part(operating room, intensive care unit, emergency room) and ward in general hospitals, and to reveal its related factors. The self-administered questionnaires were given to 393 nurses employed in 3 participating hospitals located in Daejeon City. As a results, the special part workers had higher scores of fatigue symptoms than the ward workers. Multiple stepwise analysis revealed that the factors of influence on fatigue symptoms in the special part workers included subjective health status, age and job satisfaction, and in the ward workers, the factors of influence on fatigue symptoms included subjective health status, sleep hour, shift work and job satisfaction. In conclusion, the fatigue symptoms were higher in the special part workers than the ward workers, and its related factors were different from two worker groups.

A STUDY ON THE CORROSION OF AMALGAMS IN CHLORIDE SOLUTION (Chloride용액에서의 아말감부식에 대한 연구)

  • Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.502-514
    • /
    • 1998
  • The purpose of this study is to observe the corrosion characteristcs of four dental amalgams(CAULK FINE CUT, CAULK SPHERICAL, DISPERSALLOY, TYTIN) and to determine a function of chloride concentration through the anodic polarization curve obtained by using a potentiostat. After each amalgam alloy and Hg being triturated, the triturated mass was inserted into the cylinderical metal mold, and condensed by hydrolic pressure. Each specimen was removed from the metal mold. 24 hours after condensation, specimens were polished with the emery paper and stored at room temperature for 6 months. The anodic polarization curves were employed to compare the corrosion behaviours of the amalgam m KCl and KCl-NaCl solution, which had chlonde concentration of 0.4 g/l, 0.8 g/l, 1.2 gil, and 1.6 gil at $37^{\circ}C$ with 3-electrode potentiostat. After the immersion of specimen in electrolyte for 1 hour, the potential scan was begun. The potential scan range was - 1500mV ~+800mV(vs. S.C.E.) in the working electrode and the scan rate was 50mV/sec. The results were as follows, 1. The corrosion potential. the potential of anodic current peak, and transpassive potential in the solution of high chloride concentration shifted to more cathodic direction than those in the solution of low concentration, and the current density in the solution of high chloride concentration was higher than that in the solution of low concentration. 2. The corrosion potential, the potential of anodic current peak, and transpassive potential for CAULK FINE CUT amalgam were the most cathodic among the others, and the current density were the highest among the others. 3. In the solution of low chloride concentration, the corrosion potential, the potential of anodic current peak, and transpassive potential for DISPERSALLOY were the most anodic among the others, however in the solution of high chloride concentration, those for TYTIN were the most anodic among the others. 4. The anodic polarization curve for CAULK SPHERICAL was similar to that for high copper amalgams.

  • PDF

Study on the Comparison of Heat Exchange Performance of Liquefied Gas Vaporizer at Super Low Temperature (초저온 액화가스 기화기의 열 교환성능 비교에 관한 연구)

  • Kim, Pil-Hwan;Kim, Chul-Pyo;Jeong, Hyo-Min;Chung, Han-Shik;Lee, Yong-Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.679-688
    • /
    • 2008
  • Air-heating vaporizer usually is used to regasify LNG at satellite areas because of the small demand of natural gas there. The common type of air heating vaporizer which exists in the market is the longitudinally finned type with 8 fins, 55 mm fin length and 2mm fin thickness. To contribute in developing an efficient air-heating vaporizer, experiment on finned type air-heating vaporizer using 8 fins, 50mm(fin length) with 2 mm(fin thickness) which exist in the market and 4 fins, 75 mm(fin length) with 2 mm(fin thickness), which is proposed, were conducted. Then, both types of vaporizers are compared. The experiments were conducted in one hour by varying the ambient condition and the length of the vaporizer. The ambient air was controlled so that it has the same temperature, humidity and air velocity with air condition in every season available and the length was varied 4000 mm, 6000 mm and 8000 mm for each type of vaporizer. Additional experiment with longer duration, i.e. In this experiment, the main aspects in analyzing the characteristics of the air heating vaporizer the inlet-outlet enthalpy difference and the outlet temperature of the working fluid. $LN_2$ is used to substitute LNG because of safety reason. The results show that the characteristics of the finned type 4fin75le vaporizer are comparable to finned type 8fin50le vaporizer.

A Study on the development of Explosion-proof type's the terminal box of the ventilator with the control of wind volume and operating time (풍량 및 운전시간 제어 방폭 배풍기 인버터 단자함 개발에 관한 연구)

  • Yoo, DongJoo
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.6
    • /
    • pp.187-192
    • /
    • 2018
  • This thesis is about the study of inverter terminal boxes in a explosion proof type exhaust fan that can control wind volume and operating time. In Korea, there is no ventilator to adjust the amount of wind and operating time when working in poor conditions. The purpose of the project is to create a explosion terminal box that can control the operating time and wind speed of a suitable explosion ventilator in hazardous environments. The two explosion-proof switches allow the operation time to be driven 1 hour, 3 hours and continuous time, and the speed of the induction motor rotation was set in 3 stages at 2000 rpm, 2600 rpm and 3000 rpm to control the volume. The tested motor used a half-horsepower barrier three-phase induction motor and a full-bridge inverter to set the desired flow rate and operating time.

Effects of Self-Efficacy on Jop-Stress and Work-Life Balance: Focusing on Using Structural Equation Model (자기 효능감이 직장 스트레스 및 워라밸에 미치는 영향: 구조방정식모델 활용을 중심으로)

  • Han, Seung Jo;Lee, Se Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.679-687
    • /
    • 2020
  • This study quantitatively analyzed the effects of self-efficacy in the workplace on job-stress and work-life balance (WLB) using a structural equation model (SEM) to seek ways to increase the WLB. Because the current government promotes the 52-hour weekly policy, WLB that refers to the balance between work and life that is used throughout society. In addition, self-efficacy, which was used mainly in the home and education system, has expanded its scope of application, and efforts to increase it in the workplace are working as demand for the times. The observation variables to be included in the SEM were collected from a questionnaire of 5,454 adults, and AMOS 21 was used for statistical analysis. As a result of the analysis, self-efficacy in the workplace has a negative correlation with stress, and a higher self-efficacy means a higher WLB. The results of this study did not show that the more workers are passionate about their work in the workplace due to work-oriented thinking and behavior rather than home had a lower WLB. In addition, these results can be used to analyze the WLB policy in the ROK Army.

Implementation of a Sensor Network in a Welding Workplace Based on IoT for Smart Shipyards (스마트 조선소를 위한 사물인터넷 기반 용접 작업장 센서네트워크 구축)

  • Kim, Hyun Sik;Lee, Gi Seung;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.3
    • /
    • pp.433-439
    • /
    • 2021
  • In this paper, we propose a method to implement an IoT-based sensor network for each workplace of a shipyard. Here, at the most common welding workplace in shipyards, the shipbuilding blocks are used as a communication medium to transmit information such as the worker's location, welding progress, and working hour to a server using LoRa and powerline communication. To achieve the data communication, inductive couplers and hybrid modems have been manufactured and installed on wire feeders and pin jigs to establish a sensor network. As a result of field test, the proposed system shows a success rate of data transmission and a rate of successful recognition of worker's location of about 98% or more. In addition, the process management system platform can record and display the work process data generated at the field in real time. The proposed system can be a starting point for enhancing the competitiveness of Korean shipbuilding industry through the establishment of a smart shipyard.

Estimation of Construction Equipment Production Rates: Focus on Efficiency Rate (건설기계 시공능력 산정에 관한 연구 : 작업효율 중심으로)

  • Park, Hee-Sung;Han, Ye Lyeong;Huh, Youngki;Ahn, Bang Ryul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1D
    • /
    • pp.67-72
    • /
    • 2008
  • Heavy equipment is a very important factor for successful construction implementation. Also, the cost for heavy equipment is a major part of construction cost. Therefore, the estimation of equipment cost is a critical job in the construction planning phase. A formula for production rates shown in 'Standard Unit Labor' has been used to estimate construction equipment capability per hour and cost. Although the performance of equipment has been improved, the efficiency rates in the formula are not updated lately. Therefore, this research performed several site visits to measure construction equipment working time and then calculates the efficiency rates for hydraulic backhoe, loader, and dump truck. The results show that the measured efficiencies of backhoe and loader are higher than current ones and vice versa for dump truck. This research proposes the needs for a standardized calculation formula and systematic and long-term data collection and measurement for updating efficiency rates for heavy equipment.

A Study on the Musculoskeletal Pain Experience of Dental Hygienist's Treatment Postur (치과위생사의 진료자세에 따른 근골격계 통증 경험에 대한 연구)

  • Kim, Ji-Hee;Kim, Hye-Jin
    • Journal of dental hygiene science
    • /
    • v.9 no.4
    • /
    • pp.413-418
    • /
    • 2009
  • This study was to investigate the muscoulosckeletla pain from 214 dental hygienist during treatment process in Ulsan and Kyungnam. The data collection was done from March to May in 2009 with questionnaire. The study results were as follows. In the participant's age characteristic, under 23 years old(34.1%) was majority, other participant age group were 24~26 years old(33.6%), 25~29 years old(20.6%), and over 30 years old(11.7%). Other participant characteristic were unmarried participant(86.4%), none religion(43.5%), and graduation from college(88.3%). In the participant's business characteristic, working place were dental clinic(57.5%), and dental hospital(42.5%), career was 1~2 years(42.5%) and a number of change job was once(45.1%). Salary were 1,300,000~1,490,000 won (33.6%), 1,500,000~1,990,000 won(29.9%), under 1,300,000 won(26.2%), 2,000,000~2,490,000 won(7.5%). A number of dental hygienist was over 20 person(85.9%) and the average dental hygienist was 15.6 person. A number of dentist were one person(28.5%), 2 person(22.4%), 4 person(19.2%) and the average dentist was 3.2 person. Dental hygienist's working hour was 8~9(49.5%), a large part of dental hygienist was assistance of general treatment(70.1%). Other results were 5 days/week working(60.3%), and night shift(49.1%). In an effect of musculoskeletal pain during working, neck pain was significantly influenced by body posture such as "head forward 15 degree or head round", "non balanced shoulders", "bend waist", "bend wrist", and "sit astraddle on a chair". Shoulders pain was significantly influenced by body posture such as "head forward over 15 degree", "bend waist", and "stand up straightly". Knee pain was significantly influenced by body posture such as "stand up straightly", and hip pain was influenced by "sit astraddle on chair".

  • PDF

Effect of Shift Interval for the Clinical Nurse on the Circadian Rhythm (임상 간호사의 교대근무 기간이 circadian rhythm 변화에 미치는 영향)

  • 황애란;정현숙;임영신;이혜원;김조자
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.2
    • /
    • pp.129-149
    • /
    • 1991
  • Circadian rhythm is entrained in the 24-hour time interval by periodic factors in the environment, known as zeitgeber. But most rotating work schedules are outside the range of the entrainment of the pacemaker timing the human circadian sleep - wake cycle. It has been postulated that physiological and emotional disturbances occur in most human functions when the circadian rhythm is disturbed. So application of circadian principles to the design of shift schedules can aid in maintaining the temporal integrity of the circadian system and thereby minimize for the shift worker any detrimental consequences of circadian disruption. This study was a quasi-experimental study to test the effect of shift intervals for the clinical nurse on the circadian rhythm. Twenty nurses newly employed in general units of two hospitals were selected as an experimental group and twelve college nursing students as a control group. Both groups were selected according to an established criteria using a purposive sampling technique. Ten subjects were assigned to a weekly shift group and another ten to a biweekly shift group engaged in a semi -continuous shift schedule(sunday off) with a backward direction, that is, morning -evening - night shift. The control group worked a morning shift for 42 days. Oral temperature rhythm, waking tim, sleep - wake cycle, fatigue, and mental performance were measured during the experimental period. The data collection period was from April 30, 1990 to June 10, 1990. MANOVA, paired t-test, ANOVA, and Student Newman Keuls method were used for statistical analysis. The results are summarized as follows. 1. Phase delay in the acrophase of temperature rhythm was shown according to the backward rotating shift. A complete adaptation to work on the night shift was achieved between the sixth and ninth day of the night shift. 2. There was no difference in either waking time or sleep- wake cycle according to the duration of the working day for every shift group. Significant difference was found in the waking time and the sleep -wake cycle for subjects on the morning, evening, and night shift in both of the shift groups(weekly shift group : λ=0.121, p<0.01, λ=0.112, p<0.01, biweekly shift group : λ=0.116, p<0.01, λ=0.084, p<0.01). 3. There was no difference in fatigue between the first working day and the last working day for the control group and for the biweekly shift group. In the weekly shift group, physical fatigue was significantly different for the first day and the sixth day of the night shift(t=-2.28, p<0.05). Physical fatigue and total fatigue on the first day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=5.79, p<0.01, F=4.56, p<0.05). There was a significant difference between the shift groups and the control group(p<0.05), Physical fatigue, neurosensory fatigue and total fatigue on the last day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=12.65, p<0.01, F=7.77, p<0.01, F=9.68, p<0.01). There was a significant difference between the shift groups and the control group(p<0.05). 4. No difference in mental performance was seen between the first day and the last day of work in each case. An arithmatic test on the first day of the night shift revealed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=3.79, p<0.05). There was a significant difference between the shift groups and the control group(p<0.05) . The digital symbol substitution test and the arithmetic test on the last day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=3.68, p<0.05, F=5.55, p<0.01), and both showed a significant difference between the shift groups and the control group(p<0.05). Accordingly, this study showed that during night duty, the waking time, sleep- wake cycle, and fatigue increased and mental performance decreased compared with morning and evening duty. It was also found that the weekly shift group had a higher fatigue score on the sixth day of night duty as compared to the -first day, but the waking time, sleep- wake cycle, and mental performance revealed no difference for the duration of the night duty or between shift groups, and complete adaptation of temperature rhythm was achieved between the sixth and ninth day of night duty. It is possible to conclude from these results that for intermediate circadian type in a healthy young woman, a biweekly shift system is more compatible with the circadian timing system than weekly shift system.

  • PDF