• Title/Summary/Keyword: Wiring Devices

검색결과 71건 처리시간 0.022초

차량용 와이어링 하네스 개선을 위한 브릿지 커넥터 개발에 관한 연구 (A Study of Bridge Connector Development on Wiring Harness Improvement in Vehicles)

  • 류수욱;박경석
    • 한국기계가공학회지
    • /
    • 제9권2호
    • /
    • pp.66-72
    • /
    • 2010
  • Recently a large number of electronic control devices are abruptly increasing in vehicles as the electronic industry advances. Also the number of wiring harnesses and complexity of wiring is proportionally increased to the devices. A newly developed connector named bridge connector is introduced in this study for the purpose of the wiring structure changes. A wiring structure among distributed control systems by using serial communication is proposed with the bridge connector in this paper. The bridge connector contains a auto-recovery fuse made by PTC thermistor material for the protection of the over-currents on local control devices. The auto-recovery function of the fuse is needed for the maintenance free system in the distributed controls. The PTC fuse characteristics organized in this study is tested and the results are showed in detail for the real application.

승압에 따르는 220V용 전기기기의 절연방식 결정에 관한 연구 (A Study on the Insulation Methods of 220V Home Appliances and Wiring Devices)

  • 이승원
    • 전기의세계
    • /
    • 제20권4호
    • /
    • pp.5-11
    • /
    • 1971
  • This is a study on the insulation methods of home appliances and wiring devices proper to the new electric distribution system, primary side is 22.9/13.2KV, 3 phase 4 wire multigrounding system and secondary side is 380/220V, 3 phase 4 wire common neutral system. 1800V is determined as the electrical insulation voltage of the functional insulation because the abnormal voltage rise of the neutral line is 1300V. In the case of the functional insulation faults, the following safety methods will be suggested to protect the accidental faults: (a) class I appliance (accessible metal part is earthed), (b) class II appliance (doublly insulated), (c) class III appliance (operates at low voltage source). The mechanisms of the wiring devices are not improved to guarantee for the harmful electric shock but also the electrical insulation voltage is rised to 2000V.

  • PDF

The Role of a Wiring Model in Switching Cell Transients: the PiN Diode Turn-off Case

  • Jedidi, Atef;Garrab, Hatem;Morel, Herve;Besbes, Kamel
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.561-569
    • /
    • 2017
  • Power converter design requires simulation accuracy. In addition to the requirement of accurate models of power semiconductor devices, this paper highlights the role of considering a very good description of the converter circuit layout for an accurate simulation of its electrical behavior. This paper considers a simple experimental circuit including one switching cell where a MOSFET transistor controls the diode under test. The turn-off transients of the diode are captured, over which the circuit wiring has a major influence. This paper investigates the necessity for accurate modeling of the experimental test circuit wiring and the MOSFET transistor. It shows that a simple wiring inductance as the circuit wiring representation is insufficient. An adequate model and identification of the model parameters are then discussed. Results are validated through experimental and simulation results.

LSI Packaging Technologies for High-End Computers and Other Applications

  • Inoue, Tatsuo
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2001년도 3rd Korea-Japan Advanced Semiconductor Packaging Technology Seminar
    • /
    • pp.147-164
    • /
    • 2001
  • 1. "MLS", state of the art MCM-D wiring substrate. 2. High pin-count LSl assembly. 3. Higher speed needs higher packaging density. 4. Wiring substrate, the key of LSl packaging device. 5. "Inter-Layer Transferability", a new index for the performance of wiring substrates. 6. "MLTF package", a core-less flexible package for high pin-count LSl.

  • PDF

저압용 전열수구에서 방전 신호의 발생과 검출에 관한 연구 (Studies on Generation and Detection of Discharge Signals in a Low-voltage Outlet)

  • 길경석;송재용;서황동;문승보;조영진;황돈하
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권11호
    • /
    • pp.498-502
    • /
    • 2005
  • The objectives of this paper are to provide information on the characteristics of the discharge signals in a low-voltage indoor outlet. Most of electrical fires are caused by short circuits, overheating of wires, deterioration and incomplete connection of wiring devices. The last two cases are predictable before the occurrence of fire because of its slow progress. We have simulated the discharge signals caused by the deterioration and incomplete connection of wiring devices using aged outlets. From the experimental data, we could characterize the frequency spectrums of the discharge signals depending on the cases. The higher frequency components of the signal are attenuated by the capacitance and inductance of power lines as the measuring point is getting away from the discharges. Main frequency components of the discharge signal are existent at 600kHz - 1.5MHz in incomplete connections and at 210H7z - 8MHz in deteriorations of the outlet.

의료용 도뇨관 표면의 도선용 구리 박막 증착을 위한 스퍼터링-열증착 연속공정장비의 설계 및 개발 (Design and Development of Sputter-evaporation System for Micro-wiring on Medical Catheter)

  • 장준근;정석
    • 한국정밀공학회지
    • /
    • 제16권3호통권96호
    • /
    • pp.62-71
    • /
    • 1999
  • Integrating micro-machined sensors and actuators on the conventional devices with the copper power lines was incompatible to fabricate the mass produced micro electromechanical system (MEMS) devices. To achieve the compatibility of the wiring method between MEMS parts and devices, we developed the three-dimensional sputter-evaporation system that coats micropatterned thin copper films on the surface of the MEMS element. The system consists of a process chamber, two branch chambers, the substrate holder, and a linear-rotary motion feedthrough. Thin copper film was sputtered and evaporated on the biocompatible polymer, Pellethane$^{circed{R}}$ and silicone, catheter that is 2 mm in diameter and 700 mm in length. The metal film coating technique with three-dimensional thin film sputter-evaporation system was developed to apply the power and signal lines on the micro active endoscope. In this paper, we developed the three-dimensional metal film sputter-evaporation system operated on the low temperature for the biopolymeric substrates used in the medical MEMS devices.

  • PDF

3상 히터의 불평형전류 검출에 의한 결함예측 및 보호장치의 선정 (Fault Prediction Based on Unbalanced Current Detection of Three Phase Heater and Selection of the Protective Device)

  • 이문형;정재희
    • 한국안전학회지
    • /
    • 제30권1호
    • /
    • pp.28-33
    • /
    • 2015
  • Three phase heaters in 7 buildings of 2 sites were examined for precise diagnosis. The sample size was 626. Precise examinations of current and the heater wiring status revealed contact failures and arcs in equipments that had CUF larger than 10%. Contact failures and arcs may cause electrical fire. Therefore, the correlation between the CUF and the imperfections in heater equipment and its wiring was analyzed for three phase heaters. In addition, the protection devices used for detection of heater imperfections were found to be unsuitable for the purpose. Current status of the protection devices was analyzed, and suggestions for improvements were made for new standards of the protection device selection.

박막 공정을 이용한 초소형 내시경의 MicroWiring System의 개발 (The Development of Micro Wiring System for Micro Active Endoscope)

  • 정석;장준근;한동철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.362-365
    • /
    • 1997
  • In the field of Micro-Mechanics, it has been known diffcult to integrate the micro-machine with sensor and source line for the conventional copper line cnanot be used in compact and small size. We developed a system to make thethin copper film as a connect line on the poyurethane pipe (2mm in diameter) by the evaporation technique. This system consists of an evaporation chamber two long branches, substrate hoider and a Linear-Rotary motion feed feedthrough. The results showed that thin copper film coated polyurethanc pipe could be applied th the small medical devices such as the micro active endoscope.

  • PDF

필드버스를 이용한 신호설비 제어 및 감시에 관한 연구 (A study on Control and Monitoring for Signaling system use Fieldbus)

  • 박채영;이준호;김용규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.1016-1020
    • /
    • 2005
  • The real-time monitoring and controlling between the interior and the field signaling security devices is a necessity for the train safety in terms of the train operating plan. The type wiring lower the safety level of signaling security device, because too much wiring makes the maintenance more difficult and it might be have a problem of an induction field and contact. It also need high cost. The single network communication(Fieldbus) does not need that much wiring, and the maintenance will be easier. It also guarantee the high level of stability.

  • PDF

Z-Segmentation 알고리즘을 이용한 발사체의 배선 점검 방법 (Wiring Test Method of Projectile using Z-Segmentation Algorithm)

  • 오세권;이대현;김영성;안종흠
    • 한국항행학회논문지
    • /
    • 제25권5호
    • /
    • pp.370-376
    • /
    • 2021
  • 항공 우주 산업의 발전으로 발사체의 연구가 많아지고 있다. 더불어 많은 시험이 진행하고 있고 그에 따라 많은 실패도 발생한다. 발사체는 다른 전자장비보다 위험성이 높기 때문에 실패를 최소화할 수 있어야 한다. 따라서 발사체에 전원을 공급하기 전에 배선을 검증할 필요가 있다. 이에 따라 저항 측정을 통해 배선 상태를 검증하였다. 하지만 이전의 저항측정 방식의 배선 점검은 발사체 회로의 커패시터, 인덕터등의 소자들 때문에 정확한 측정을 할 수 없다. 본 논문에서는 TDR 미터를 이용하여 케이블 및 발사체의 연결 상태에서 임피던스를 측정한다. 측정한 정상상태의 임피던스의 기준 값을 설정하기 위해 Z-Segmentation 알고리즘을 사용한다. Z-Segmentation 알고리즘은 우선 임피던스 파형의 피크 값들을 칼만 필터를 이용하여 찾고 찾은 피크값을 Segmentation을 통해 최종 impedance peak segment를 얻는다. 이런 방법으로 배선의 정상 상태에 대한 기준 값으로 설정하고 이를 기준으로 배선 상태를 판정한다.