• Title/Summary/Keyword: Wiring Devices

Search Result 71, Processing Time 0.024 seconds

A Study of Bridge Connector Development on Wiring Harness Improvement in Vehicles (차량용 와이어링 하네스 개선을 위한 브릿지 커넥터 개발에 관한 연구)

  • Ryu, Su-uk;Park, Kyoung-Seok
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.2
    • /
    • pp.66-72
    • /
    • 2010
  • Recently a large number of electronic control devices are abruptly increasing in vehicles as the electronic industry advances. Also the number of wiring harnesses and complexity of wiring is proportionally increased to the devices. A newly developed connector named bridge connector is introduced in this study for the purpose of the wiring structure changes. A wiring structure among distributed control systems by using serial communication is proposed with the bridge connector in this paper. The bridge connector contains a auto-recovery fuse made by PTC thermistor material for the protection of the over-currents on local control devices. The auto-recovery function of the fuse is needed for the maintenance free system in the distributed controls. The PTC fuse characteristics organized in this study is tested and the results are showed in detail for the real application.

A Study on the Insulation Methods of 220V Home Appliances and Wiring Devices (승압에 따르는 220V용 전기기기의 절연방식 결정에 관한 연구)

  • Sung Won Rhee
    • 전기의세계
    • /
    • v.20 no.4
    • /
    • pp.5-11
    • /
    • 1971
  • This is a study on the insulation methods of home appliances and wiring devices proper to the new electric distribution system, primary side is 22.9/13.2KV, 3 phase 4 wire multigrounding system and secondary side is 380/220V, 3 phase 4 wire common neutral system. 1800V is determined as the electrical insulation voltage of the functional insulation because the abnormal voltage rise of the neutral line is 1300V. In the case of the functional insulation faults, the following safety methods will be suggested to protect the accidental faults: (a) class I appliance (accessible metal part is earthed), (b) class II appliance (doublly insulated), (c) class III appliance (operates at low voltage source). The mechanisms of the wiring devices are not improved to guarantee for the harmful electric shock but also the electrical insulation voltage is rised to 2000V.

  • PDF

The Role of a Wiring Model in Switching Cell Transients: the PiN Diode Turn-off Case

  • Jedidi, Atef;Garrab, Hatem;Morel, Herve;Besbes, Kamel
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.561-569
    • /
    • 2017
  • Power converter design requires simulation accuracy. In addition to the requirement of accurate models of power semiconductor devices, this paper highlights the role of considering a very good description of the converter circuit layout for an accurate simulation of its electrical behavior. This paper considers a simple experimental circuit including one switching cell where a MOSFET transistor controls the diode under test. The turn-off transients of the diode are captured, over which the circuit wiring has a major influence. This paper investigates the necessity for accurate modeling of the experimental test circuit wiring and the MOSFET transistor. It shows that a simple wiring inductance as the circuit wiring representation is insufficient. An adequate model and identification of the model parameters are then discussed. Results are validated through experimental and simulation results.

LSI Packaging Technologies for High-End Computers and Other Applications

  • Inoue, Tatsuo
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2001.09a
    • /
    • pp.147-164
    • /
    • 2001
  • 1. "MLS", state of the art MCM-D wiring substrate. 2. High pin-count LSl assembly. 3. Higher speed needs higher packaging density. 4. Wiring substrate, the key of LSl packaging device. 5. "Inter-Layer Transferability", a new index for the performance of wiring substrates. 6. "MLTF package", a core-less flexible package for high pin-count LSl.

  • PDF

Studies on Generation and Detection of Discharge Signals in a Low-voltage Outlet (저압용 전열수구에서 방전 신호의 발생과 검출에 관한 연구)

  • Kil, Gyung-Suk;Song, Jae-Yong;Seo, Hwang-Dong;Moon, Seung-Bo;Cho, Young-Jin;Hwang, Don-Ha
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.498-502
    • /
    • 2005
  • The objectives of this paper are to provide information on the characteristics of the discharge signals in a low-voltage indoor outlet. Most of electrical fires are caused by short circuits, overheating of wires, deterioration and incomplete connection of wiring devices. The last two cases are predictable before the occurrence of fire because of its slow progress. We have simulated the discharge signals caused by the deterioration and incomplete connection of wiring devices using aged outlets. From the experimental data, we could characterize the frequency spectrums of the discharge signals depending on the cases. The higher frequency components of the signal are attenuated by the capacitance and inductance of power lines as the measuring point is getting away from the discharges. Main frequency components of the discharge signal are existent at 600kHz - 1.5MHz in incomplete connections and at 210H7z - 8MHz in deteriorations of the outlet.

Design and Development of Sputter-evaporation System for Micro-wiring on Medical Catheter (의료용 도뇨관 표면의 도선용 구리 박막 증착을 위한 스퍼터링-열증착 연속공정장비의 설계 및 개발)

  • Chang, Jun-Keun;Chung, Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.3 s.96
    • /
    • pp.62-71
    • /
    • 1999
  • Integrating micro-machined sensors and actuators on the conventional devices with the copper power lines was incompatible to fabricate the mass produced micro electromechanical system (MEMS) devices. To achieve the compatibility of the wiring method between MEMS parts and devices, we developed the three-dimensional sputter-evaporation system that coats micropatterned thin copper films on the surface of the MEMS element. The system consists of a process chamber, two branch chambers, the substrate holder, and a linear-rotary motion feedthrough. Thin copper film was sputtered and evaporated on the biocompatible polymer, Pellethane$^{circed{R}}$ and silicone, catheter that is 2 mm in diameter and 700 mm in length. The metal film coating technique with three-dimensional thin film sputter-evaporation system was developed to apply the power and signal lines on the micro active endoscope. In this paper, we developed the three-dimensional metal film sputter-evaporation system operated on the low temperature for the biopolymeric substrates used in the medical MEMS devices.

  • PDF

Fault Prediction Based on Unbalanced Current Detection of Three Phase Heater and Selection of the Protective Device (3상 히터의 불평형전류 검출에 의한 결함예측 및 보호장치의 선정)

  • Lee, Mun Hyung;Jung, Jae Hee
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.28-33
    • /
    • 2015
  • Three phase heaters in 7 buildings of 2 sites were examined for precise diagnosis. The sample size was 626. Precise examinations of current and the heater wiring status revealed contact failures and arcs in equipments that had CUF larger than 10%. Contact failures and arcs may cause electrical fire. Therefore, the correlation between the CUF and the imperfections in heater equipment and its wiring was analyzed for three phase heaters. In addition, the protection devices used for detection of heater imperfections were found to be unsuitable for the purpose. Current status of the protection devices was analyzed, and suggestions for improvements were made for new standards of the protection device selection.

The Development of Micro Wiring System for Micro Active Endoscope (박막 공정을 이용한 초소형 내시경의 MicroWiring System의 개발)

  • Jung, Seok;Chang, Jun-Keun;Han, Dong-Chul
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.362-365
    • /
    • 1997
  • In the field of Micro-Mechanics, it has been known diffcult to integrate the micro-machine with sensor and source line for the conventional copper line cnanot be used in compact and small size. We developed a system to make thethin copper film as a connect line on the poyurethane pipe (2mm in diameter) by the evaporation technique. This system consists of an evaporation chamber two long branches, substrate hoider and a Linear-Rotary motion feed feedthrough. The results showed that thin copper film coated polyurethanc pipe could be applied th the small medical devices such as the micro active endoscope.

  • PDF

A study on Control and Monitoring for Signaling system use Fieldbus (필드버스를 이용한 신호설비 제어 및 감시에 관한 연구)

  • Park, Chae-Young;Lee, Jun-Ho;Kim, Yong-Kyu
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.1016-1020
    • /
    • 2005
  • The real-time monitoring and controlling between the interior and the field signaling security devices is a necessity for the train safety in terms of the train operating plan. The type wiring lower the safety level of signaling security device, because too much wiring makes the maintenance more difficult and it might be have a problem of an induction field and contact. It also need high cost. The single network communication(Fieldbus) does not need that much wiring, and the maintenance will be easier. It also guarantee the high level of stability.

  • PDF

Wiring Test Method of Projectile using Z-Segmentation Algorithm (Z-Segmentation 알고리즘을 이용한 발사체의 배선 점검 방법)

  • Oh, Se-Kwon;Lee, Dae-Hyun;Kim, Yung-Sung;An, Jong-Heum
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.5
    • /
    • pp.370-376
    • /
    • 2021
  • development of the aerospace industry is increasing the research of projectiles. In addition, many tests are under way and many failures occur accordingly. Projectiles should be able to minimize failures because they are more dangerous than other electronic equipment. Therefore, it is necessary to verify wiring before powering the projectile. Accordingly, the wiring status was verified by resistance measurements. However, the wiring test of the previous resistance measurement method cannot be accurately measured due to devices such as capacitors and inductors in the projectile circuit. In this paper, impedance is measured in the connection state of cables and projectiles using a TDR meter. The Z-Segmentation algorithm is used to set the reference value for the measured steady state impedance. The Z-Segmentation algorithm first finds the peak values of the impedance waveform using a Kalman filter and obtains the final impedance peak segment through segmentation. In this way, the wiring status is determined based on the reference value for the normal state of the wiring.