• Title/Summary/Keyword: Wire to water efficiency

Search Result 31, Processing Time 0.028 seconds

The development and the characteristics of environmentfriendly sinker for octopus drift-line (문어흘림낚시용 친환경 봇돌의 개발과 그 특성)

  • An, Young-Il;Yoon, Sang-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.44 no.3
    • /
    • pp.184-193
    • /
    • 2008
  • For environment-friendly fishery, the lead sinkers of octopus drift line were developed with the environmentfriendly sinker, and their characteristics and performance were investigated. To make the environmentfriendly sinker, the hydrate ceramic material was developed, and to increase the weight and strength, the iron power was added to it. The fishing hook was machine-made, and standardized, by using 60cm iron wire. For the manufacture of the sinker, the first, the mold was made, and then, hydrate ceramic material and water were quantitatively mixed. The mixture was poured into the mold prepared with a fishing hook already inserted, and had hardened for several hour, before it was taken out of the mold as a complete sinker. The sinkers were made in the 8 types ranging in weight from 150 to 500g, and their specific gravities were diverse from 2.871 to 6.637, which was 0.19 to 0.44 times lower than that of lead. The movement of the environment-friendly sinker by flume tank was possible in the weaker current speed than the similar lead sinker. In the coastal fishing grounds of Gangwon province, the comparison of catching efficiency was made between the improved fishing gears composed of the environment-friendly sinkers and artificial baits, and the current used fishing gears of lead sinkers and pig-fat baits. The result showed the tendency in which the improved fishing gears caught the bigger octopuses than the current used fishing gears. In the quantity and number of the fish catch per unit fishing gear, the improved fishing gear showed a little more catch than the current used fishing gear, regardless of the fishing area. However, the number of the improved fishing gears lost during fishing operation was similar to that of the current used fishing gears.

Developing an improved water discharge anchor & trap bolt to prevent basic salt penetration to harbor structures (해수 염기 침투방지를 위한 성능개선 형 물배출 앵커 및 트랩볼트 개발에 관한 연구)

  • Ock, Jong-Ho;Moon, Sang-Deok;Lee, Hwa-Sun;Shin, Kyung-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.674-682
    • /
    • 2018
  • Large industrial motors require a large area because of the high risk of shutdown accidents and large industrial accidents due to the lowering of the dielectric strength of the armature windings and overheating problems. Therefore, there is a demand for a large-capacity motor that has small size, light weight, and excellent dielectric strength compared with conventional motors. Superconducting motors have advantages of high efficiency and output power, low size, low weight, and improved stability. This results from greatly increasing the magnetic field generation by using superconductive field coils in rotating machines such as generators and motors. It is very important to design and analyze the cooling system to lower the critical temperature of the wires to achieve superconducting performance. In this study, a field loss analysis and low-temperature heat transfer analysis of the cooling system were performed through the conceptual design of a 100-HP high-temperature superconducting synchronous motor. The field loss analysis shows that a uniform pore magnetic flux density appears when high-temperature superconducting wire is used. The low-temperature heat transfer analysis for gaseous neon and liquid neon showed that a flow rate of 1 kg/min of liquid neon is suitable for maintaining low-temperature stability of the high-temperature superconducting wire.

Effects of Red Ginseng on Exercise Capacity and Peripheral Fatigue in Mice

  • Kim, Daehyun;Lee, Byounggwan;Kim, Heejin;Kim, Mikyung
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.2
    • /
    • pp.175-184
    • /
    • 2021
  • Objective: Fatigue can decrease both quality of life and work efficiency. Ginseng is one of the most popular herbal treatments for improving personal health, with applications in treating fatigue. However, the exact mechanisms of anti-fatigue effects are still unclear. Thus, we investigated the effect of red ginseng powder (RGP) on exercise capacity and peripheral fatigue using both behavioral and molecular experiments in mice. Design: Four-groups behavioral and molecular experiment. Methods: Male 6-weeks-old ICR mice were treated with distilled water, 100, and 200 mg/kg RGP for 5 days via oral administration. The exercise capacity of each animal group was measured by locomotor activity, rota-rod, hanging wire, and cold swimming tests. Additionally, after performing the treadmill to induce fatigue, lactate expression and molecular experiments were investigated using mice gastrocnemius. Results: Mice treated with RGP exhibited increased exercise capacity in the behavioral tests. Additionally, RGP induced a dose-dependent decrease in lactate levels after high-intensity exercise, and Monocarboxylate transporter (MCT) 4 expression increased in groups treated with RGP. However, there was no significant change in MCT1. Conclusions: These results suggest that RGP exerts several anti-fatigue properties by lower lactate and improved exercise capacity. Increased MCT4 expression may also affect lactate transport. Thus, this study suggests that the anti-fatigue properties of RGP might be associated with MCT4 activity.

Design of 1 MW High-temperature Superconducting Motor with Water-cooled Armature (수냉식 전기자로 구성된 1 MW 고온초전도 동기모터의 설계)

  • Baik, S.K.;Lee, J.D.;Kim, S.H.;Lee, E.Y.;Sohn, M.H.;Kwon, Y.K.;Moon, T.S.;Park, H.J.;Kim, Y.C.;Lee, J.Y.;Hong, J.P.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1258-1260
    • /
    • 2005
  • Superconducting synchronous motors and generators have the field coil composed of superconductor with almost zero resistance at superconducting state. Therefore, co or loss at the conventional field coil is eliminated and the superconducting machine gets higher efficiency. The armature coil of the superconducting machine is composed of cower wire and supported by non-magnetic material such as FRP(Fiber Reinforced Plastic). Although a fully-superconducting machine with superconducting armature coil has been researched, it was not developed toward industrial application because of AC transporting loss and difficulty in construction of the cooling structure and so on. This paper contains the design procedure of a 1 MW superconducting synchronous motor using high-temperature superconductor only for the field coil. Especially, the armature coil is designed by water-cooling in order to dissipate Joule heat easily. Moreover, 3-dimensional electromagnetic design is conducted to get a proper design result and reduce design errors from 2-dimensional approach.

  • PDF

A Study on the Improvement Effects of Soft Ground through In-Situ Construction of Quick Lime Pile (생석회파일 현장시험시공 통한 연약지반 개량효과에 관한 연구)

  • 천병식;고갑수;이용한
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.41-48
    • /
    • 2000
  • Most land development projects and large scale civil works require a great amount of sand. And sand is also the most favorable material for soft ground improvement. The demand for sand is soaring rapidly due to increased number of projects regardless of its limited supply. Therefore, it is not difficult to predict that sand may become depleted and no longer be available as ground improvement material in the near future. Against this backdrop, developing an inexpensive sand-substitution material with an efficient accessibility will be necessary and urgently called for. So quick lime could be recommended as the substitutional material for sand. Quick lime is now preferred by forward developed nations. If Korea is able to take advantage of its abundant supply, economical efficiency could be achieved through massive production as well as being able to take advantage of utilization of natural resources. In this respect the purpose of this paper was to estimate improvement effect of soft ground though in-situ construction of quick lime pile. In-situ construction was peformed in road construction site of soft clay and in this study quick lime from Dan-yang that was estimated prominently in aspect of engineering characteristics was used. Quick lime piles were installed by 1.5m, 2.0m, 3.0m spacing to confirm improvement effect according to spacing and installed piles are 0.4m in diameter, up to 5m in length and the density of quick piles installed is 1.4 t/㎥. Vibrating wire pore water pressure cell was installed to confirm consolidation characteristics in surrounding of quick lime piles and both laboratory test and field test were carried out to confirm strength increase. In conclusion, soft ground improvement by quick lime piles was confirmed.

  • PDF

Electrochemical Characteristics in Sea Water of Al-3%Mg Arc Spray Coating Layer for Corrosion Protection with Sealing Treatment (후처리 적용에 따른 방식용 Al-3%Mg 용사코팅 층의 해수 내 전기화학적 특성)

  • Park, Il-Cho;Kim, Seong-Jong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.5
    • /
    • pp.974-980
    • /
    • 2015
  • Arc thermal spray coating using Al-3%Mg thermal spray wire was carried out to prevent steel from corrosion damage under the marine environment. Post-sealing was applied to Al-3%Mg spray coating treatment using organic/inorganic composite ceramics in order to improve the corrosion resistance of the as-sprayed coating. The results of various electrochemical experiments with sealing treatment indicated that the improvement in corrosion resistance was observed due to low current density in all applied potential range during anodic and cathodic polarization experiments. Futhermore, the natural potential measurement exhibited severe potential fluctuation due to influence of micro-crack presence on the surface of sealed thermal spray coating layer. In addition, the sealed layer was easily eliminated during anodic polarization. Nevertheless, Al-3%Mg spray coating layer improved corrosion resistance by sealing treatment because the sealed coating efficiency was determined to be 92.11%, indicating the exterior environment barrier effect which is based on the Tafel analysis.

A Comparative Study of Sea Trials and Production Processes for Propulsion Type Working Boats with a Tuna Purse Seiner (다랑어 선망어선 탑재용 보조 작업선의 추진기 형태 변화에 대한 제작과정 및 해상시운전 비교 연구)

  • Ha, Seoung-Mu;Jang, Ho-Yun;Seo, Hyoung-Seock;Seo, Kwan-Cheol
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.5
    • /
    • pp.595-602
    • /
    • 2017
  • In Korea, much research and development have occurred to enhance the technological competitiveness of tuna purse seining fisheries. Due to these efforts, fishing efficiency has been improved with the development of radar, sonar and global positioning systems for fish detection and revisions to the hull forms of tuna purse seiners. However, for skiff boats, net boats and speed boats, which are auxiliary working boats mounted on tuna purse seiners, technology has lagged behind relative to the modernization of the main vessel. In this study, the hull of an existing propeller-based net boat with steel wire net to protect tuna was changed to the hull of a water jet propulsion vehicle to reduce resistance and improve maneuverability. As a result, a prototype of a water jet propulsion option was produced according to the aluminum structure strength standards specified by the Ministry of Oceans and Fisheries, and safety was confirmed by performing a drop test. Moreover, through a sea trial test, an existing net boat was shown to have a speed of 12.0knots and a towing force of 2,545 kgf at 2,500 RPM. The prototype had a speed of 26.7 knots and a towing force of 2,011 kgf at 3,200 RPM, which satisfied the towing capacity standards of auxiliary working boats mounted on tuna purse seiners.

A Study of Efficient Removal of 2-Methylisoborneol and Geosmin by Pulsed Ultraviolet and Ultrasound (효율적인 2-Methylisoborneol, Geosmin의 제거를 위한 Pulsed UV 공정과 Ultrasound 공정의 비교 연구)

  • Han, Jonghun;Hur, Jiyong;Kim, Kangwook;Lee, Junyoung;Park, Wonseok;Lee, Jongyeol;Her, Namguk
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • The degradation of off-flavors which is 2-Methylisoborneol (2-MIB) and geosmin by means of ultrasound (US) and pulsed ultraviolet (PUV) irradiation and its combination with catalyst (wire mesh, wire mesh coated TiO2, and TiO2) and additive (H2O2) were investigated via water system. A combination treatment of TiO2 and H2O2 heterogeneity with US (24 kHz) and PUV (6000 W) has shown improved results in destroying 2-MIB and geosmin, which may be attributed to chain reactions by the enhanced formation of hydroxyl radicals (·OH) through H2O2 dissociation and reactive oxide ions of TiO2 addition. Rapid degradation of off-flavors occurred within 2 min under PUV process with H2O2 100 mg/L (81.5% for 2- MIB; 79.3% for geosmin) and TiO2 100 mg/L (83.7% for 2-MIB; 79.8% for geosmin), while compared with H2O2 100 mg/L (58.4% for 2-MIB; 58.0% for geosmin) and TiO2 100 mg/L (59.2% for 2-MIB; 38.5% for geosmin) within 5 min under US process. Surprisingly, the emphasis was given on the comparison with the same injected energies between PUV and US on degradation efficiency. Based on the injected energy comparison, the US provided better degradation performance under equal input power of 200 kJ with H2O2 100 mg/L, while compared with H2O2 100 mg/L under PUV process. Our findings suggest that US can be more effective compared to PUV for the degradation of off-flavors in aspect of energy consumptions.

Design and Implementation of Monitoring System for Submarine Optical fiber Cable Work (해저 광케이블 작업을 위한 모니터링 시스템의 설계 및 구현)

  • 이태오;정성훈;임재홍
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.205-208
    • /
    • 2002
  • When establishing the submarine optical fiber table between international and domestic, marine survey in advance it grasps the submarine geological features which is accurate and a depth of water condition. And the route which is safe for selecting and submarine optical fiber cable laying it is a work which secures an ease one location. If also, the PLGR the submarine of optical fiber table root the sea contamination material (rope, wire and net) it removes in advance and if the submarine of the optical fiber cable ease it does to arrive safely. And it is a work the Plough and ROV laying work hour laying work efficiency improvement and laying equipment it will be able to protect. So, This paper presents the monitoring system of ship information management and operation for marine survey and PLGR work in submarine optical fiber table construction enterprise. In order to achieve these purpose, overall serial multi-port communication modulo of configuration, realtime processing for management and operation of receiving data, realtime graph and a printout are described.

  • PDF

Development of Multi-purpose Marine Wastes Cleaning Systems for the Shallow Waters(PART II : System Development and Performance Evaluation) (천수용 다기능 해양폐기물 수거시스템 개발(PART II : 시스템 구성 및 성능시험))

  • Cho Yong-Jin;Moon Il-Sung;Shin Myung-Soo;Yu Jeong-Seok;Kang Chang-Gu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.5 no.2
    • /
    • pp.62-67
    • /
    • 2002
  • This paper - following 'Development of multi-purpose marine waste cleaning systems for the shallow waters (Part I : preliminary conceptual design)'- describes on the system development and the sea trial performance evaluation(Cho[2003]). The multi-functional seabed waste collecting system and the towing hook system were developed. The maximum working depth of these systems are 15 and 100 meters, respectively(MOMAF[2001]). For the multi-purpose use to collect the marine waste, this system contains floating waste collecting device for the waste on seawater and remained waste collecting device for the waste on seabed, while steel wire cutting system is added for higher efficiency In order to evaluate the system performance, the prototype of multi-functional system was constructed and the sea trial test at shallow water were carried out. As a result, this system operated well with safe and without any interaction so that the developed systems are practicable and applicable.

  • PDF