• Title/Summary/Keyword: Wire communication

검색결과 482건 처리시간 0.082초

전기 철도의 전력선 통신을 위한 전차선과 조가선의 통신 특성 분석 (Analysis of Communication Characteristics on Contact wire and Messenger wire of Electric Railroad for Power Line Communication)

  • 이희준;안승호;강승욱;이종구
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.157-162
    • /
    • 2010
  • Power line communication, using 25[kV] high voltage of railway catenary, is to provide information which is real-time safety information for train operations and train workers in driving. Lots of noise were occupied in the contact wire by electrical and communication equipments. A signal attenuation was caused characteristics of the contact wire and messenger wire. For relaying communications to transmit information using the contact wire, catenary the noise and signal attenuation were investigated. And the final goal of the study was realized to transmit video information by power line communication on electric railway.

전기철도의 전력선 통신망 설계에 관한 연구 (A Study on the Network Design of Electric Railway for Power Line Communication)

  • 김재문;김양수;안승호;이희준;이종구
    • 한국산학기술학회논문지
    • /
    • 제11권10호
    • /
    • pp.3756-3760
    • /
    • 2010
  • 본 논문은 조가선을 이용한 전기철도의 전력선 통신을 위한 네트워크 설계를 제안한다. 전기철도에서 필수적인 전차선 및 조가선을 이용하여 전력선 통신에 대한 타당성 검토를 선행연구로 수행하였다. 이를 위해 우선 무가압상태에서 조가선에 신호결합기를 취부하여 양방향 데이터 통신을 구현하였다. 데이터 전송속도가 양호하게 나타났으며 이를 토대로 전력선 통신을 위한 주요 구성품을 제시하고 네트워크 설계를 제안하였다. 향후 네트워크 설계에 대한 타당성을 확보하기 위해 지속적인 연구를 수행하고자 한다.

자동차 통신을 위한 광대역 커넥터 특성 연구 (A study on the characteristics of wide bandwidth connector for automotive communication)

  • 김병우
    • 한국산학기술학회논문지
    • /
    • 제13권1호
    • /
    • pp.33-38
    • /
    • 2012
  • 본 연구에서는 나선형 형태의 와이어를 자동차 무선통신(5.925GHz)용 차량 커넥터에 적용 가능성을 제안하였다. 이 나선형 와이어 형태의 커넥터 설계는 나선형 평균 반경, 나선형 피치, 나선형 와이어 자체의 반경, 나선형와이에서 접지 부분까지의 거리를 중요 설계인자로 판단하여 실시하였다. 이 같은 설계 해석 및 결과는 자동차 통신용 커넥터 설계를 위한 가장 적합한 나선형 와이어 치수 결정에 사용될 수 있을 것이다. 나선형 와이어가 삽입된 최적화된 자동차 WAVE용 커넥터는 삽입손실이 5.925GHz 대역에서 -0.76dB 이내로 발생되었다. 이 삽입손실 결과는 기존의 일반 커넥터에 비하여 21% 성능이 향상된 것이다. 따라서, 본 커넥터 해석결과는 자동차 통신을 위한 고주파대역의 최적 커넥터 설계에 유용하게 사용할 수 있을 것이다.

전철 피뢰기를 이용한 전력선 통신 데이터 전송 특성 (The Characteristic of Data Transmission for Power Line Communication using an AC Arrester for Electric Railway)

  • 김재문;안승호;김양수;김철수
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.497-502
    • /
    • 2012
  • Power line communication(PLC) is a kind of communication technology, was made use of controling a frequency narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. This paper deals with the PLC of electric railway using capacitive signal coupler. An AC arrester for catenary is used as a capacitive signal coupler, has the characteristic of capacitor. As a result of field test, a messenger wire used PLC contain much of conducted noise about overall frequency band and also signal attenuation rate increased with increasing frequency between two points. and the communication speed of PLC used messenger wire is 793kbps at a distance of 40m. Experimental results show the possibility of PLC using a messenger wire and an AC arrester for catenary at electric railway.

항공기 디지털 전자식 비행제어 시스템 기술 개발 동향 (Aircraft Digital Fly-By-Wire System Technology Development Trend)

  • 채성병
    • 한국전자통신학회논문지
    • /
    • 제18권3호
    • /
    • pp.509-520
    • /
    • 2023
  • 항공기에서 소형 제트기까지 항공기에 적용되는 플라이 바이 와이어 시스템의 구성 및 특성등에 대하여 기술 하였다. 특히 비행조종컴퓨터 다중화 방안과 데이터 통신 버스, 조종면 작동기, 플라이 바이 와이어 시스템을 통하여 적용되는 제어 법칙 등에 대한 기술 개발 동향에 대해 고찰하였다. 전투기에 처음 적용되었던 플라이 바이 와이어 시스템은 여러 가지 장점으로 인해 까다로운 인증과정을 거쳐 민간 항공기에까지 적용되었고, 최근에는 소형제트기까지 적용 범위가 확장되고 있으며 미래에는 대부분 플라이 바이 와이어 항공기가 주를 이룰 것으로 전망된다.

지능형 LED 조명 시스템의 신뢰성 확보를 위한 유무선 이중망 통합 인터페이스 구현 (Implementation of Integrated Interface based on Wire and Wireless Dual Network for Ensuring the Reliability of Intelligent LED Lighting System)

  • 이운선;박태진;박만곤
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.306-312
    • /
    • 2014
  • The ZigBee communication method, which is the most frequently applied to the LED lighting control system, has drawbacks of low-speed and low-capacity, and the communication failure possibility due to environmental influences is on the rise. Therefore, it is important to secure the communication reliability by applying an integrated interface with a wire-wireless dual-network. This paper developed a communication module, which has a platform converging and combining the ZigBee of USN environments with the PLC of power line communication environments, to implement a dualized communication interface system supporting the wire-wireless integrated protocol, and implemented a wire-wireless networking device and a control system software technology. As a result, it was automatically switched into the PLC communication within 4.4 seconds on average when there was an access failure in the ZigBee communication network, so a reliable communication network was built.

Implementation of Single-Wire Communication Protocol for 3D IC Thermal Management Systems using a Thin Film Thermoelectric Cooler

  • Kim, Nam-Jae;Lee, Hyun-Ju;Kim, Shi-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제12권1호
    • /
    • pp.18-23
    • /
    • 2012
  • We propose and implement a single-wire communication protocol for thermal management systems using thin film thermoelectric modules for 3D IC cooling. The proposed single-wire communication protocol connects the temperature sensors, located near hot spots, to measure the local temperature of the chip. A unique ID number identifying the location of each hot spot is assigned to each temperature sensor. The prototype chip was fabricated by a $0.13{\mu}m$ CMOS MPW process, and the operation of the chip is verified.

메시지 스케줄링을 이용한 Brake-by-wire 시스템의 Redundancy Management (Redundancy Management of Brake-by-wire System using a Message Scheduling)

  • 윤종운;김기웅;김태열;김재구;이석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.717-720
    • /
    • 2000
  • Event-driven communication protocols such as CAN(Controller Area Network) have inherent packet delays due to the contention process for the use of network medium. These delays are stochastic in nature because most packets arrive at random time instants. The stochastic property of the delay adversely influences the control system's performance in terms of stability, responsiveness and steady-state error. Another problem for safety-critical application such as brake-by-wire systems is the reliability of the communication modules that can fail abruptly. This paper deals with two methods to overcome the above problems : (i) scheduling method that can maintain packet delays under some acceptable level, and (ii) redundancy management of communication modules that prescribes dual-redundancy modules' behavior when one of them fails.

  • PDF

전송선로를 가진 Chua 회로에서의 카오스 암호화 (Chaos Secure Communication of Chua's Circuit with Transmission Line)

  • 고재호;배영철;임화영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 B
    • /
    • pp.530-532
    • /
    • 1997
  • In this paper, a transmitter and a receiver using two identical Chua's circuits are proposed and a wire secure communications are investigated. A secure communication method in which the desired information signal is synthesized with the chaos signal created by the Chua's circuit is proposed and information signal is demodulated also using the Chua's circuit. The proposed method is synthesizing the desired information with the chaos circuit by adding the information signal to the chaos signal in the wire transmission system. After transmitting the synthesized signal through the wire transmission system, it is confirmed the feasibility of the secure communication from result of demodulated signals and recovered wire tapped signals.

  • PDF

$\cdot$무선통신을 이용한 해양환경 모니터링 시스템의 개발 (Development of a sea environmental monitoring system using wire and wireless communication)

  • 김진호;한정만;김상봉
    • 한국해양공학회지
    • /
    • 제10권4호
    • /
    • pp.160-165
    • /
    • 1996
  • This paper introduces a sea environmental monitoring system for measuring pH,DO, level and temperature. This system is developed using a personal computer(PC) and multiple single board computers. A PC communicates with the single board computers by awireless communication method and transfers data to another personal computer for processing data by a modem. The values of pH,Do,level and temperature, which are basic components to estimate sea environment, are real-timely processed in the single board computer at each stations, and transferred to the monitoring PC. These data are graphically shown on the PC monitor and logged on the data processing system in the form of file. Using the wire and wireless communication system, user can constantly analyze the acquired data and detect the sea contamination.

  • PDF