AN EVALUATION OF ENERGY PERFORMANCE IN SUPER HIGH-RISE APARTMENT HOUSING WITH EXTERIOR WINDOW TYPES

  • Sang-Ho Lee;Yong-Ho Park;Jong-Chan Lee
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1637-1642
    • /
    • 2009
  • This study evaluates the energy performance of super high-rise residential buildings with e-QUEST simulation and calculates the annual cooling and heating load. The result of this study have concluded that the most influential factor is the characteristics of the window and also suggest the most efficient window system from the result of calculation of different glasses' cooling and heating load. The result of this study shows that The most efficient method to enhance the energy performance is to use low reflective 3 pairs Low-E glass and Low-E coating(inside of outer glass) pair glass.

  • PDF

Energy demand analysis according to window size and performance for Korean multi-family buildings

  • Huh, Jung-Ho;Mun, Sun-Hye
    • Architectural research
    • /
    • v.15 no.4
    • /
    • pp.201-206
    • /
    • 2013
  • Special attention is required for the design of windows due to their high thermal vulnerability. This paper examines the problems that might arise in the application of the u-value, by reflecting the changes in the u-value of the window, depending on the window-to-wall ratio obtained in an energy demand analysis. Research indicates that the u-value of a window increases with an increase in the difference between the u-values of the frames and the glass. Relative to the changes in the u-value of the windows, the energy demand varied from 1.3% to 9.3%. Windows with a g-value of 0.3 or 0.5 displayed a higher energy demand than windows with a g-value of 0.7. Therefore, when the difference between the performance of the glass and the frame is significant, especially when the g-value is small, a modified heat transmission coefficient should be applied to the window size during the evaluation of the building energy demand.

A Comparative Analysis of the Energy Load due to Window Area Ratio of Domestic Public Buildings

  • An, Kwang-Ho;Hyun, Eun-Mi;Kim, Yong-Sik
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • In the case of public buildings, fast communication and transparency in the administration and the public, as well as ensuring visibility and lighting performance using a glass curtain wall is symbolically expressed through the transparent glass skin. This study is a simulation in order to derive the basic data for the establishment of the improvement of the heating and cooling load analysis according to the window area ratio changes with respect to the high effectiveness of the government's large public building energy consumption analysis and green building certification system of guidelines was analyzed by a change in the energy load. Glass curtain wall is light and visibility, the symbolic meaning of communication, etc., but is widely used in a variety of characteristics, in terms of energy consumption being disadvantaged sheath plan should have been. Design, including the Atrium, is much less energy than energy consumption by the window area ratio. Thus, while compliance with design guide lines, the atrium and I like the burden of a large space ratio and energy load consists of only glass suggest that require more research on that given in the guidelines.

A Study on Impact Damage Characteristics of the Window Glass for High Speed Train (고속열차 객실 유리창 충격파손특성 비교 연구)

  • Jeon, Chang-Sung;Kim, Young-Guk;Yun, Su-Hwan;Kwon, Hyeok-Bin;Park, Tae-Won
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.3
    • /
    • pp.217-223
    • /
    • 2012
  • This study describes an experimental investigation about the impact damage characteristics of various types of high speed train window glass. Kinds of impact test standards for glass were studied and impact test considering scattering ballast were developed. Windows with external impact side made with annealed, heat strengthened and tempered glasses are likely to be broken by sharp tipped falling object. Broken shape of annealed glass is like line in part and that of heat strengthened glass is line on the whole. Tempered glass is destroyed to pieces. The change of tip type from sharp to blunt makes the higher destroyed level. Tempered glass has higher strength than annealed glass with blunt tip. When the protective films are attached to glasses, strength against destruction increases. In case of real ballast test, glasses without protective films were destroyed, but those with protective films are hard to be broken.

Speech Intelligibility Analysis on the Laser Detected Sound of the Glass Windows (유리창의 레이저 탐지음에 대한 음성명료도 분석)

  • Kim, Seock-Hyun;Lee, Hyun-Woo;Kim, Hee-Dong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.127-134
    • /
    • 2009
  • In this study, possibility of the laser eavesdropping is investigated on the window glasses with various thicknesses, Glass windows are excited by maximum length sequency (MLS) signal and the vibration sound is detected by a laser doppler vibrometer. From the detected sound, speech intelligibility is objectively estimated. Speech transmission index (STI), which is based on the modulation transfer function (MTF). is calculated for the estimation. Finally, disturbing wave effect on the speech intelligibility is analysed by using an outside speaker and a window shaker attached on the glass window. The purpose of the study is to estimate the possibility of remote eavesdropping by the laser sensor and to evaluate the performance of the homemade window shaker to protect from the remote eavesdropping.

Heating & Cooling Energy Performance Analysis of an Office Building according to SHGC level of the Double & Triple Glazing with Low-e Coating (이중 및 삼중 로이창호의 일사획득에 따른 사무소건물의 냉난방에너지 성능분석)

  • Kim, Hyo-Joong;Park, Ja-Son;Shin, U-Cheul;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.90-95
    • /
    • 2008
  • An SHGC(Solar Heat Gain Coefficient) is a determinant of total flux of solar radiation coming indoor and a critical factor in evaluating heating and cooling load. U-value represents heat loss while SHGC denominates heat gain. Recently, windows with high solar gain, mid solar gain or low solar gain are being produced with the development of Low-E coating technology. This study evaluated changes in energy consumption for heating and cooling according to changes in SHGC when using double-layered Low-E glass and triple layered Low-E glass in relation to double layered clear glass as base glass. An Office was chosen for the evaluation. For deriving optical properties of each window, WINDOW 5 by LBNL, an U.S. based company. and the results were analyzed to evaluate performance of heat and cooling energy on anannual basis using ESP-r, an energy interpretation program. Compared to the energy consumption of the double layered clear glass, the double layered Low-E glass with high solar gain consumed $69.5kWh/m^2,yr$, 9% more than the double layered clear glass in cooling energy. The one with mid solar gain consumed $63.1kWh/m^2,yr$, 1% less than the base glass while the one with low solar gain consumed $57.6kWh/m^2,yr$, 10% less than the base glass. When it comes to tripled layered glass, the ones with high solar showed 2% of increase respectively while the one with mid solar gain and low solar gain resulted 5% and 11% in decrease in energy consumption due to low acquisition of solar radiation. With respect to cooling energy. it was found that the lower the SHGC. the less energy consumption becomes.

  • PDF

A study on the Pressure Test of the Glass Window for High Speed Train (고속철도차량용 창문유리의 압력시험에 관한 연구)

  • Chang, Dae-Sung;Yi, Won
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.5
    • /
    • pp.391-397
    • /
    • 2011
  • In this paper, the pressure endurance test of passenger train's glass window which was developed for next high speed train was studied. At first, pressure test equipment which will be able to generate the maximum pressure same as crossing case between two trainsets in the tunnel was developed. Afterwards the pressure test and evaluation that are based on NFF31-314 were carried out and studied.

A study on the functional transition of Korean rolling stock's window pane. (한국 철도차량 창호유리의 기능적 변천에 대한 고찰)

  • Lee, Heung-Jae;Chang, Dae-Sung
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.323-337
    • /
    • 2009
  • This paper researched the adiabatic characteristic, safety and sound insulation characteristic of rolling stock window pane type and transition process of korean train vehicle window glass, and also including investigating a hereafter course of development. The window pane have provided the romantic feeling and the external scenery of train travel to the passenger in period of korea 110 year railway history. From the adiabatic viewpoint, this paper reviewed heat conductivity(U-value) and solar factor according to window pane type, including the safety and sound transmission loss of window pane.

  • PDF

A Study on the Window Glass Pressure for High-speed Train (고속철도차량의 유리창 압력에 관한 연구)

  • Kwon, Hyeok-Bin;Chang, Dae-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.4
    • /
    • pp.371-375
    • /
    • 2010
  • In order to decide the strength requirement of the window glass for the high-speed train, the pressure change during the passage of the EMU type high-speed train has been numerically simulated. Based on the calculation results, the pressure difference between the inner and outer pressure of the cabin has been calculated to yield the amount of load acting on the window glass of the cabin. To simulate the pressure field generated by the high-speed train passing through the tunnel, computational fluid dynamics based on the axi-symmetric Navier-Stokes equation has been employed. The pressure change inside a train has been calculated using first order difference approximation based on a linear equation between the pressure change ratio inside a train and the pressure difference of inside and outside of the train.

An Experimental Study on Transmission Loss of Window (창호의 차음성능에 관한 실험적 연구)

  • 이성호;정갑철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.241-246
    • /
    • 2001
  • This study considered the transmission loss and frequency characteristecs of window, and examined the transmission loss for each type of windows to design an optimized window for blocking external noise. Moreover this has detect the transmission loss which depending on the thickness and the types(single and fair glass) of window as several major factors of transmission loss design. With this result, this study suggests a window design guide for much silent condition which is below the level of noise standard recommended.

  • PDF