• Title/Summary/Keyword: Window area ratio

Search Result 83, Processing Time 0.037 seconds

Study on Estimate of Thermal Resistance of PVC Frame Window Due to Material Composition (PVC 창호의 구성에 따른 단열성능 예측에 관한 연구)

  • Sung, Uk-Joo;Lee, Jin-Sung;Cho, Soo;Jang, Cheol-Yong;Paek, Sang-Hun;Song, Kyoo-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1075-1080
    • /
    • 2006
  • Purpose of this study is proposal of estimating method about window thermal performance that based on KS F 2278 'Test method of thermal resistance for windows and doors' due to material composition of PVC frame window. First step of this study is research of present state about material composition of PVC frame window. Second is selection of main effective elements about window thermal resistance. For example, composition of Glazing, Frame area ratio of total window area, frame width, opening type, area of heat transfer and so on. Third is multiple regression analysis about thermal performance of PVC frame window due to main effective elements. It produces equations of multiple regression analysis due to opening type. Case of sliding window is $Y=0.149+0.034X_g+0.248X_{far}$, 4track sliding is $Y=0.584+0.175X_g+1.355X_{far}-0.008X_{fw}$, Tilt & Turn window is $Y=-0.161+0.076X_g+0.576X_{far}+0.0008X_{fw}$.

  • PDF

Daylighting Performance of a New-Developed Energy Efficient Double-Skin Window System (에너지절약형 이중외피 창호의 기본채광 성능)

  • Park, Jong-Myung;Kim, Jae-Hoon;Choi, Jin-Woo;Lim, Hong-Soo;Kim, Gon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.117-122
    • /
    • 2008
  • The apartment will be much more convenient than the other one in the application of green technologies, providing the merits by mass production. For example, pre-manufactured building materials can be effectively adapted to the formation of buildings. Recently, the form of double-enveloped window system has been developed for the purposed of minimizing energy loss occurred around windows. On the other hand, the expansion of balcony area was legalized and thus, a visual buffer area does not exist any more. All-glass window wall on apartment houses without a balcony produces pretty harmful area with direct sunbeam. A various types of glass can be applied to the window system and it plays a critical role in the determination of inner visual environment. For the purpose of verifying the potential of its daylighting, a mock-up model has been constructed and tested. The refurbished version of conventional window shows its illuminated characteristics. Clear and Low-e glass have been adapted for window area and daylighting ratio has been compared in both test cells.

  • PDF

The Building Energy Efficiency Rating Evaluation of Apartment depending on SC and Window area ratio (차폐계수와 창면적비에 따른 공동주택의 건물에너지효율등급 평가)

  • Jang, Cheol-Yong;Han, Hye-Sim;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.38-43
    • /
    • 2010
  • Enhancement of exterior's insulation performance like wall or window etc. is general way for building's energy efficient and thermal performance. But exterior's opening plan is important for minimizing the energy consumption and heat loss. In this paper, energy saving rate will be analyzed and compared considering the window area's rate and window's SC(Shading Coefficient) in a apartment with Building Energy Efficiency Rating System's evaluation tool. In the process of evaluation, energy saving rate is measured at each stage of the window area's rate from 20% to 60% every 10% term and the shading coefficient value from 1.0 to 0.6. As a result of this research, energy saving evaluation could not be measured exactly with existing evaluation tool. Accord this research, Building Energy Rating System's evaluation range is needed to be broaden for exact evaluation of energy saving rate.

Comparative Studies on Lighting Environment and Energy Performance depending on the Transmittance of Window and Slat Angle of Blind (창호의 투과율과 블라인드 슬랫각도에 따른 빛환경 및 에너지성능 비교 연구)

  • Sim, Se-Ra;Yoon, Jong-Ho;Shin, U-Cheul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.256-263
    • /
    • 2011
  • Recently, curtain wall structure is constructed according to increasing high rise building. Glass is usually used in opening of curtain wall structure and window area ratio is finally increased. Excessive Daylighting and solar radiation by large window area ratio cause discomfort glare and add to cooling load in the case of office that is heavy on lighting and cooling. Therefore, this study suggests to use low transmittance window for solve those problems. Indoor lighting environment and building energy performance were analyzed by increasing transmittance from 10% to 90% and comparing fixed venetian blind. Consequently, the range of transmittance that is possible to daylighting and prevent discomfort glare. Secondary energy consumption is efficient in the case that transmittance is the range of from 20% to 50%, primary energy consumption is nice on from 20% to 40%. If those result put together, the range of window transmittance from 30% to 50% is proper in the office in lighting environment and energy consumption aspects.

  • PDF

Energy Consumptions and Daylight Illumination levels of a Multi-beded Patient Room according to the Window Shapes and Shading (창의 형태 및 차양 계획에 따른 다인 병실의 에너지소비량과 주광조도의 평가 및 분석)

  • Choi, Changdae;Kwon, Soonjung;Kim, Sunsook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.18 no.3
    • /
    • pp.29-39
    • /
    • 2012
  • Window and shading designs have a great influence on energy consumption and daylighting in buildings. As far as energy is concerned, small window area is advantageous. But it is not good to the patient healing in hospital. So it is important to find out the optimum window shape which is favorable for both energy consumption and patient healing. In this study, annual energy consumption and daylight illumination levels were analyzed according to the window shapes and shading devices for a multi-beded patient room in hospitals. The simulations were conducted for 19 different cases by COMFEN 4.0 computer simulation program. The results of this paper are as follows. First, window to wall area ratio and shading devices have great influences on annual energy consumption. But it is a problem in that they decrease significantly daylight level in bed room. Second, considering the same energy consumption, reducing the width of window rather than the hight of window is desirable for the secure of daylight level. Third, increase of the number of horizontal shade is not desirable in south face of the building for the energy consumption and daylight level. Fourth, sun shade is not necessary in north face of the building for the energy consumption and daylight level.

Comparison assessment of semi-transparent solar cell for BIPV windows (반투과형 태양전지를 이용한 창호형 BIPV 건물의 환경성능 분석)

  • Chung, Min Hee
    • Land and Housing Review
    • /
    • v.11 no.1
    • /
    • pp.87-94
    • /
    • 2020
  • To implement the planning of zero-energy buildings, their energy performance must be improved, and renewable energy applications must also be included. To accelerate the use of renewable energies in such buildings, BIPVs should be actively used in windows and on roofs. Window-type BIPVs are being developed in various forms depending on the size, composition, area ratio of the window, specification of glass, and so on. To analyze the applicability of various solar cells as window-type BIPVs, in this study, we evaluated their applicability, at the current development level, by analyzing the indoor illuminance, heat gain and heat loss; the cooling, heating, and lighting energy levels; and the generation performance of the various solar cells. To enhance the future applicability of window type BIPV, we analyze the overall energy performance of the building, according to changes in visible light transmittance and generation efficiency. The main research results are as follows. The area ratios above the standard illuminance, based on the window type and according to the VLT, were in order of low-e glazing, a-Si window, DSSC window, and c-Si window. The heat gain of the semi-transparent solar cell winodw was remarkably low. The energy consumption of buildings was highest in the order of c-Si window, DSSC window, a-Si window, and clear low-e window. However, in the case of including the power generation performance of the solar cell, the energy consumption was found to be high in order of DSSC window, c-Si window, a-Si window, and clear low-e window. In the future, if a window-type BIPV is developed, we believe that improvement in power generation performance and improvement in visible light transmittance will be needed.

A Study on the Characterization of Fire Plume Ejected from an Opening according to the Opening Form and the Balcony of Apartment in Korea (국내 공동주택의 개구부형태 및 발코니 유·무에 따른 분출화염 성상에 관한 연구)

  • Lee, Kyu-Min;Koo, Tae-Yoon;Hwang, Eu-Cheong;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.37-38
    • /
    • 2017
  • This study identified the effects of flame on the upper by fire plume ejected. we implemented model experiment according to investigation of housing area effect, window aspect ratio and balcony availability. we confirmed that opening ratio was increased according to housing area larger. the square window confirmed that is progressing fire plume ejected of free space. According to the value of an opening aspect ratio 'n' getting higher, the horizontal widow is getting that increased the risk as the fire spread an external to the top of opening. it is determined to the fundamental solution about fire safety in the extended balcony of apartment.

  • PDF

A Study on the Analysis of Heating and Cooling Load through Applying Window Film Insulation (열 차단 필름의 적용에 따른 냉난방 부하 분석에 관한 연구)

  • Kim, Seok-Hyun;Cho, Young-Hum
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.47-53
    • /
    • 2013
  • In order to reduce the energy consumption of the building, much effort is being made. The problems are that excessive solar radiation in summer and the heat loss in winter by the increase of window area. To prevent this problems, government limited the window area ratio or the performance of windows in new buildings. In order to reduce energy consumption of the existing buildings, the window film insulation is spotlight because the window film insulation was simple to installation. This study confirmed the performance of the window film insulation and affect to heating & cooling load of buildings. The impact of the window film insulation coating was confirmed by experiment. And this study confirmed the annual heating & cooling load by simulation. As a results, the surface temperature of coated window was higher than the surface temperature of existing window. The window film insulation was increased surface temperature of window. And this study confirmed that the increased surface temperature was slightly affected the room air temperature through experiment of the insulation box. The results of the heating and cooling load by simulation, this study confirmed that the case of coated window film insulation decreased cooling load in summer and increased heating load in winter. Also the annual total heating & cooling load was increased a little in the case of coated the window film insulation.

COMPARISON OF ATMOSPHERIC CORRECTION ALGORITHMS FOR DERIVING SEA SURFACE TEMPERATURE AROUND THE KOREAN SEA AREA USING NOAA/AVHRR DATA

  • Yoon, Suk;Ahn, Yu-Hwan;Ryu, Joo-Hyung;Won, Joong-Sun
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.518-521
    • /
    • 2007
  • To retrieve Sea Surface Temperature(SST) from NOAA-AVHRR imagery the spilt window atmospheric correction algorithm is generally used. Recently, there have been various new algorithms developed to process these data, namely the variable-coefficient split-window, the R54 transmittance-ratio method, fixed-coefficient nonlinear algorithm, dynamic water vapour (DWV) correction method, Dynamic Water Vapour and Temperature algorithm (DWVT). We used MCSST (Multi-Channel Sea surface temperature) and NLSST(Non linear sea surface temperature) algorithms in this study. The study area is around the Korea sea area (Yellow Sea). We compared and analyzed with various methods by applying each Ocean in-situ data and satellite data. The primary aim of study is to verify and optimize algorithms. Finally, this study proposes an optimized algorithm for SST retrieval.

  • PDF

Development and comparative analysis of slat angle control algorithm of venetian blind according to window-to-wall ratio and zone orientation (창면적비 및 향변화에 따른 슬랫형 블라인드의 최적각도 제어 알고리즘 산출 및 비교분석)

  • Kwon, Hyuk-Ju;Lee, Keum-Ho;Lee, Kwang Ho
    • KIEAE Journal
    • /
    • v.17 no.4
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: Most contemporary office buildings supply external views, a sense of openness and a sense of time to their occupants by adopting the curtain walls, which are equipped with an outer cover having large window area. As a result, the amount of radiation increases, adversely affecting cooling load during the summer in office buildings. Although solar radiation decreases heating load and reduces energy costs during the winter period, due to the characteristics of offices where occupants work largely during daytime, the cooling load is important compared to the heating. Therefore, diverse measures to resolve those trade-offs and annual energy cost have been investigated. Method: In this study, the annual thermal load was comparatively analyzed according to the slat angle of the venetian blind along with lighting control technique. Result: After selecting effective conditions, in order to resolve such issues, this study established automated control strategies of slat angle depending on the window-to-wall ratio and zone orientation, so that the findings of this study can be effectively generalized to other circumstances.