In order to reduce the energy consumption of the building, much effort is being made. The problems are that excessive solar radiation in summer and the heat loss in winter by the increase of window area. To prevent this problems, government limited the window area ratio or the performance of windows in new buildings. In order to reduce energy consumption of the existing buildings, the window film insulation is spotlight because the window film insulation was simple to installation. This study confirmed the performance of the window film insulation and affect to heating & cooling load of buildings. The impact of the window film insulation coating was confirmed by experiment. And this study confirmed the annual heating & cooling load by simulation. As a results, the surface temperature of coated window was higher than the surface temperature of existing window. The window film insulation was increased surface temperature of window. And this study confirmed that the increased surface temperature was slightly affected the room air temperature through experiment of the insulation box. The results of the heating and cooling load by simulation, this study confirmed that the case of coated window film insulation decreased cooling load in summer and increased heating load in winter. Also the annual total heating & cooling load was increased a little in the case of coated the window film insulation.
Keywords
Window; Window film insulation; College building; Heating&cooling load; Energy simulation;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Kim. S. H., The Evaluation of Cooling Loadby The Window Film Insulation in College Building, Journal of the Korea Solar Energy Society, spring conference, 2012, vol. 32, No. 1, pp. 549-552, 2012
2 Yool Park, Jong-Il Park, A study of Energy use Impacts by SHGCs of Windows in Detached House, Korea Journal of Air-Conditioning Refrigeration Engineering, vol. 22 No. 4, pp. 189-196, 2010   과학기술학회마을
3 Yool Park, Jong-Il Park, Analysis of Energy Performance by Window Directions in Apartment, 2012 Summer Conference of Air-Conditioning Refrigeration Engineering, pp. 1041-1044, 2012
4 Yoon, Yong-Sang, Yoon, Jae-Hoon, Choi, Won-Ki, Kwon, Young-Cheol, A Fundamental Study on the Optimal Window Applications According to the Window Ratio and SHGC in Office Buildings, Journal of KIAEBS Vol. 6, No. 1, 2012, pp. 38-45
5 Nam. J. W., Won. J. S., Thermal Performance Evaluation of The Window Film Insulation for Building Energy Savings, Journal of the Korea Solar Energy Society, fall conference, 2008, pp. 75-80, 2008
6 Kang. E. Y., Oh. M. W., Kim. B. S., A Study on the Heat Transfer Phenomen on through the Glazing System, Journal of the Korea Solar Energy Society, fall conference, 2009, Vol. 29, No. 2, pp. 32-36, 2009
7 Sung. U. J., Jang. C. Y., Cho. S., Lee. S. S., Experimental Study On Thermal Performance Of Heat Absorbing Glass Window, Association Branch of the Architectural Institute of Korea, annual conference, 2006, v. 01, pp. 675∼678, 2006