• 제목/요약/키워드: Window Glazing

검색결과 72건 처리시간 0.039초

BIPV 시스템에서의 모듈 종류에 따른 건축적 특성 연구 - 채광형 시스템을 중심으로 - (A Study of the Architectural Characteristic Depending upon the Module in the BIPV System)

  • 이응직;이충식
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.196-202
    • /
    • 2008
  • Effective climate protection is a most important tasks of our time. The BIPV is one of the most interesting and promisingly possibilities of an active use of solar energy at the building. In this study it was analyzed by the case study the function of the requirement of the BIPV-module as building material and this architectural characteristic according to the kind of the module. Therefore the goal of this study is to get securing the application information of BIPV as windowpane. BIPV modules are manufactured in the form of G/G. In the case of the crystal type the Transparent and the light Transmission is to be adjusted by the spacer attitude of the cell. Although this type could not be optimal for light effect of indoors because of the inequality of shade, the moving shade play makes a dramatic Roomimage by the run of sun. The application of this type would be for canopy, window or roof in the corridor or resounds. With amorphous the type it is to be manufactured simply largely laminar, and thus that will shorten building process. There is a relatively good economy to use and to the window system easily. After the production technology is easy the transparency of the modules to adjust, and the module shows to a high degree constant characteristics of light permeability and transparency. Without mottle of module shade is good the use for the window or roof glazing of office, library, classroom, etc. to adapt. The BIPV modules took generally speaking a function as building material to the daylight use, shading, isolation and also to the sight. That means that BIPV modules have as multifunctional system to sustainable architecture good successes and they are at the same time as Design element for architecture effectively.

  • PDF

이중 및 삼중 로이창호의 일사획득에 따른 사무소건물의 냉난방에너지 성능분석 (Heating & Cooling Energy Performance Analysis of an Office Building according to SHGC level of the Double & Triple Glazing with Low-e Coating)

  • 김효중;박재성;신우철;윤종호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.90-95
    • /
    • 2008
  • An SHGC(Solar Heat Gain Coefficient) is a determinant of total flux of solar radiation coming indoor and a critical factor in evaluating heating and cooling load. U-value represents heat loss while SHGC denominates heat gain. Recently, windows with high solar gain, mid solar gain or low solar gain are being produced with the development of Low-E coating technology. This study evaluated changes in energy consumption for heating and cooling according to changes in SHGC when using double-layered Low-E glass and triple layered Low-E glass in relation to double layered clear glass as base glass. An Office was chosen for the evaluation. For deriving optical properties of each window, WINDOW 5 by LBNL, an U.S. based company. and the results were analyzed to evaluate performance of heat and cooling energy on anannual basis using ESP-r, an energy interpretation program. Compared to the energy consumption of the double layered clear glass, the double layered Low-E glass with high solar gain consumed $69.5kWh/m^2,yr$, 9% more than the double layered clear glass in cooling energy. The one with mid solar gain consumed $63.1kWh/m^2,yr$, 1% less than the base glass while the one with low solar gain consumed $57.6kWh/m^2,yr$, 10% less than the base glass. When it comes to tripled layered glass, the ones with high solar showed 2% of increase respectively while the one with mid solar gain and low solar gain resulted 5% and 11% in decrease in energy consumption due to low acquisition of solar radiation. With respect to cooling energy. it was found that the lower the SHGC. the less energy consumption becomes.

  • PDF

실측 실험을 통한 단열문의 열성능 평가 (Thermal Performance Assessment of Insulated door by experiment.)

  • 장철용;김치훈;안병립;홍원화
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.47-52
    • /
    • 2011
  • Currently, Exterior wall's U-value about building envelope is 0.36 W/$m^2K$(Central Region), but window's one is 2.1 W/$m^2K$ according to air gap of glazing, filling gas, coating and type of windows. The door"s one is 1.6~5.5 W/$m^2{\cdot}K$ depending on material and configuration of door. As such, energy loss per unit of door is considerably larger like windows. The door for the recognition was relatively low because energy loss through the door is relatively small compared to window area. In this paper, thermal performance was analyzed through simulation targeting the door which has thermal break that can improve the insulation performance and doesn't have one. As a results of simulations, case1 was calculated as the average of 1.63 w/m2k and case 2 was calculated as the average of 4.14 w/m2k. The thermal performance of door depends on the type and condition of insulations. As a results of final simulations, Case1 was calculated as 1.06 w/m2k and Case2 was calculated as 1.27 w/m2k. As a results of the experiments, thermal performance of case 1 was measured as 1.28 w/m2k. Error between experiments and simulations is considered problems encountered when creating the samples. The effect of door frame on the overall thermal performance is slight because it's a small proportion of the door frame.

오피스텔 모델건물의 생애주기비용 분석에 의한 다층유리창 경제성 비교 (Comparison on the Economical Efficiency of the Multiple Glazed Windows According to Life Cycle Costing of an Officetel Model Building)

  • 정근주
    • 한국주거학회논문집
    • /
    • 제17권4호
    • /
    • pp.101-109
    • /
    • 2006
  • The purpose of this study was to suggest ways on reducing the cooling and heating energy cost of the officetel building with the multiple glazing windows according to Life Cycle Costing. This study consisted of an hour-by hour energy simulation program and further data from the EnergyPlus V1-2-2 to the four pane type windows that were applied with 2 low-e polyester film and krypton gas to the officetel model building. It was determined that the four panes type windows that had 2 low-e polyester film and krypton gas applied to, them showed a cooling and heating cost reduction over traditional double glazed windows that were filled with air. According to this study, as well as the information from chart 4.5 and the LCC it was determined that the present value of the four panes of windows that had 2 low-e polyester film and krypton gas applied to them showed. a 11.4% reduction in heating and cooling in comparison to the traditional double glazed windows that were filled with air.

2-Dimensional inverse opal structured VO2 thin film for selective reflectance adjustment

  • Lee, Yulhee;Yu, Jung-Hoon;Nam, Sang-Hun;Seo, Hyeon Jin;Hwang, Ki-Hwan;Kim, Minha;Lee, Jaehyeong;Boo, Jin-Hyo
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.410.1-410.1
    • /
    • 2016
  • Vanadium dioxide ($VO_2$) is a well-known material that exhibits a metal-semiconductor transition at 340 K, with drastic change of transmittance at NIR region. However, $VO_2$ based thermochromics accompany with low visible transmittance value and unfavorable color (brownish yellow). Herein, we demonstrate the adjustment of visible transmittance of $VO_2$ thin film by nanosphere template assisted patterning process using sol-gel method. 2-Dimenstional honeycomb shape was varied as function of diameter of nanosphere and coating conditions. The morphological geometry of the films was investigated by FE-SEM and AFM. Result shows that inversed shape of nanosphere was formed clearly and pattern width was altered according to the bead size. This structure creates the geometrical blank area from the position of nanosphere which improves the optical transmittance at the visible region. Moreover, such patterned $VO_2$ thin film not only maintains the optical switching efficiency, but also generate the gorgeous scattering effect which presumably support the glazing application.

  • PDF

에너지 저감형 그린홈 프로토타이핑을 위한 설계요소 분석 연구 (Analytic Study on the Design Elements for Energy Conservative Green-Home Prototyping)

  • 김정은;장성주;하미경;성혜연;김경완
    • KIEAE Journal
    • /
    • 제11권4호
    • /
    • pp.63-70
    • /
    • 2011
  • In respond to the global energy crisis and climate change, there have been many ongoing national efforts to develop a sustainable housing prototype followed by "2 million Green Home Project" in Korea. More than 50% of nation's population are currently living in apartment housing thus the country is seriously in need of developing green apartment prototype. In this research, we focused on energy-conservative green apartment design prototype that have both passive components and active systems explored in a systemic design approach. After selecting an existing basic apartment unit, we analyzed and compared statistical data with the simulated annual energy consumption to match these two data sets for validating simulation accuracy performed with TRNSYS package. We performed energy simulations with different passive design factors such as varied insulation thickness, window types and infiltration rates as well as the active design factors including boilers and lighting fixtures to analyze their impacts on the energy performance of the housing unit using TRNSYS software. As a result, we acquired significant energy reduction effect with explored design strategies but the life cycle cost analysis for the final design guidline would need to be performed. In this study, we focused on a systematic comparative energy analysis based on TRNSYS that can improve the design of a green apartment housing.

첨단채광시스템 실험용 Mock-Up 모형의 형상 및 모니터링 프로토콜 시스템에 관한 비교분석 - IEA SHC Task21을 중심으로- (Comparative Analysis on the Mock-ups' Configuration and Monitoring Protocol System of Advanced Daylighting Systems for Daylighting Experiment - Focused on IEA SHC Task21-)

  • 정인영;최상현;김정태
    • KIEAE Journal
    • /
    • 제4권1호
    • /
    • pp.11-20
    • /
    • 2004
  • Innovative daylighting systems in buildings in various climatic zones around the world have been developed under the IEA SHC Task21. The performance assessment were obtained by monitoring the most systems using full-scale test model rooms or actual buildings under real sky conditions. This study aims to analyze the configuration and monitoring system of the nine Mock-up models of the IEA SHC Task21 comparatively. For the purpose, the geometry of the test rooms (length, width, height, window area, glazed area and occupied), reflectance of walls, floor and ceiling, transmittance of glazing (transmittance for hemispherical irradiation, normal irradiation and U-value) were compared. And equipment for measurement (manufacturer, range, calibration, maximum calibration error, cosine response error, fatigue error), and data acquisition system (manufacturer, type, number of differential analogue input channels, A/D converter resolution in bits, data acquisition software) were also analyzed comparatively. Some findings of these experimental methodology of standard monitoring have been proven to be a valuable one for future assessment of advanced daylighting systems in our country.

실내 주광조도 간이 예측식을 활용한 담천공 시의 자연 채광 성능 평가 (Application of Simplified Daylight Prediction Method for Daylighting Performance Evaluation on Overcast Sky)

  • 윤갑천;윤수인;김성식;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제34권5호
    • /
    • pp.1-9
    • /
    • 2014
  • Daylight is very useful to control the indoor environment, and can save energy in buildings. So it is necessary to evaluate the daylighting performance of buildings. We proposed a simplified equation that can be used in the early stages of design. And we verified the equation by using the measured illuminance data from the 1/5 scale model. We compared the calculated indoor illuminances and measured illuminance including Daylight Factors of scale model in order to verify the applicability of the simplified equation, and proved the analyzed values are acceptable. When we have a target value of the Daylight Factor, we just have to determine the window area, transmittance of the glazing system, and indoor surface reflectance, then can achieve it with this simplified equation.

투과율에 따른 비정질실리콘 BIPV 시스템 효율 평가 (Performance Evaluation of a-Si BIPV System According to Transmittance Variation)

  • 차광석;이병두;김강석;신승철;이대우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.60.1-60.1
    • /
    • 2010
  • 공동주택에서 태양광발전(PV)을 통한 세대 전기에너지 이용은 모듈 설치 면적의 제약으로 인해 전 세대를 대상으로 활용하기에 현실적으로 어려움이 있다. 특히 남향이나 남동, 남서향으로 위치한 거실 창호를 활용하는 경우에도 결정질 실리콘(crystalline silicon) 태양전지 셀로 인한 실내 음영문제 등으로 건물통합형 태양광발전(BIPV) 시스템의 가시성을 확보하는데 한계가 있다. 따라서 이런 문제점을 극복하고자 투광형 비정질실리콘(amorphous silicon) 태양전지를 이용한 발코니창호/커튼월 BIPV 시스템을 구축하고, 테스트베드를 통한 적용성 평가 검증을 수행하였다. 테스트베드는 KCC 중앙연구소 1층 외부 측창에 결정질 BIPV 모듈(A2PEAK 사(社), 최대 출력 210 Wp, W 2,000 mm ${\times}$ H 1,066 mm)과 10% 및 30% 투광형 비정질 BIPV 모듈(Sharp 사(社) See Through type, 최대 출력 135 Wp/123 Wp, W 1,930 mm ${\times}$ H 1,180 mm)을 각각 설치(남서 $30^{\circ}$, 수직 $90^{\circ}$)하여, 2009년 5월에서 8월 사이 4개월에 걸친 모니터링을 통해 실제 발전량 데이터를 확보, 시스템에 대한 분석을 진행하였다. 분석 결과, 설치용량당 일평균 발전량은 결정질형이 1.46 kWh/kWp, 10% 투광형은 1.10 kWh/kWp, 30% 투광형은 0.73 kWh/kWp을 나타내었다. 10% 투광형과 30% 투광형의 모듈 성능 차이는 크지 않으나 발전량에 있어서는 큰 차이를 보였고, 10% 투광형의 설치용량당 일평균 발전량은 경정질형의 75.2% 수준으로 투광형 비정질실리콘 BIPV 시스템의 창호 적용 가능성을 확인하였다. 특히 세대 거실 창호를 통한 가시성 확보는 기존 결정질 BIPV 창호의 단점을 개선하였다. 건자재 일체화로 구축된 가시성확보 BIPV시스템 창호는 단위 세대별 적용이 쉽고, 공동주택에서 PV 시스템의 설치면적을 극대화시키므로 향후 Zero Energy 공동주택 구축에도 활용성이 클 것으로 기대된다.

  • PDF

역사적 건축물의 에너지 효율 향상을 위한 계획기법 -서양의 연구동향 및 사례를 중심으로- (Technical Measures for Improving Energy Efficiency in Historic Buildings -Focused on Researches and Case Studies of the West-)

  • 김태영
    • 한국농촌건축학회논문집
    • /
    • 제20권1호
    • /
    • pp.69-76
    • /
    • 2018
  • This study is to research technical measures for improving energy efficiency in the conservation and reuse of historic buildings focused on the recent research trends and case studies of the west. These measures are broadly classified into three types, the passive measures for saving energy and increasing comfort, the most cost-effective energy saving strategies, and the renewable energy sources. Firstly, the passive measures are divided into the elements and systems. The passive elements are awnings and overhanging eaves, porches, shutters, storm windows and doors, and shade trees. There are also the natural ventilation systems such as the historic transoms, roofs and attics to improve airflow and cross ventilation to either distribute, or exhaust heat. Secondly, the most cost-effective energy efficiency strategies are the interior insulation, airtightness and moisture protection, and the thermal quality improvement of windows. The energy efficiency solutions of modern buildings are the capillary-active interior insulation, the airtightness and moisture protection of interior walls and openings, and the integration of the original historic window into the triple glazing. Beyond the three actions, the additional strategies are the heat recovery ventilation, and the illumination system. Thirdly, there are photovoltaic(PV) and solar thermal energy, wind energy, hydropower, biomass, and geothermal energy in the renewable energy sources. These energy systems work effectively but it is vital to consider its visual effect on the external appearance of the building.