Browse > Article

Comparison on the Economical Efficiency of the Multiple Glazed Windows According to Life Cycle Costing of an Officetel Model Building  

Jung Gun-Joo (부경대 건축학부)
Publication Information
Journal of the Korean housing association / v.17, no.4, 2006 , pp. 101-109 More about this Journal
Abstract
The purpose of this study was to suggest ways on reducing the cooling and heating energy cost of the officetel building with the multiple glazing windows according to Life Cycle Costing. This study consisted of an hour-by hour energy simulation program and further data from the EnergyPlus V1-2-2 to the four pane type windows that were applied with 2 low-e polyester film and krypton gas to the officetel model building. It was determined that the four panes type windows that had 2 low-e polyester film and krypton gas applied to, them showed a cooling and heating cost reduction over traditional double glazed windows that were filled with air. According to this study, as well as the information from chart 4.5 and the LCC it was determined that the present value of the four panes of windows that had 2 low-e polyester film and krypton gas applied to them showed. a 11.4% reduction in heating and cooling in comparison to the traditional double glazed windows that were filled with air.
Keywords
Cooling and Heating Energy Cost; Energy Conservation; Multiple Window; Low-e film; Inert gas;
Citations & Related Records
연도 인용수 순위
  • Reference
1 김병수.임오연(2005.3), 시각적 쾌적성과 에너지 성능분 석에 의한 오피스 창호의 적정 투과율 선정. 대한건축학회 논문집 계획계 21권 3호
2 Euro-American Glazing Company, Heat mirror Technology, http://www.eagfacades.com/, 2006.1
3 Advanced Window Technology, Green Building International Council, http://ca.greenbuilding/, 2006.1
4 Glass on web, Articles, Pyrolitic or Vacuum Coated Glass, http://www.glassonweb.com/articles/article/180/, 2006.1
5 Wikipedia web com, http://en.wikipedia.org/wiki/Noble_ gas, 2006.01
6 National Glass Com, Reflected Coated Glass, http:// www.nationalglass.com.au/products/03/03.html, 2006.1
7 Minneapolis Oxygen Company, Krypton Introduce, http://www.mplosz.com/krypton.html, 2006.1
8 US Department of energy, EnergyPlus V1-2-2, http:// www.eere.energy.gov/, 2005.02
9 SQUARE ONE ECOTECT WeatherData, Seoul South Korea Weather Data, ewa file, http://www.squl.com/ downloads/weather.html, 2006.1
10 Lawrence Berkeley National Laboratory, Environmental Energy Technologies Division, Building Technologies Department.http://windows.lbl.gov/software/window/ window.html, 2006.1
11 홍성희.장문석.박효순.양관섭(2001.12), 공동주택의 에 너지소비원단위 설정 연구, 대한건축학회 논문집 계획계 17권 12호
12 Glass on web, Glass manual, http://www.glassonweb.com /glassmanual/topics/index/lowe.htm, 2006.1
13 김광호.김병선(2005.8), 소규모 유리외피 사무소 빌딩 사 례를 통한 온열환경과 냉방부하 저감방안에 관한 연구, 대한건축학회 논문집 계획계 21권 8호
14 석호태.곽현철.정지나.송승영(2005.10), 커튼윌 외피시 스템 벽체부의 전열특성에 관한 실험적 연구, 대한건축학회 논문집 계획계 21권 10호