• Title/Summary/Keyword: Winding technique

Search Result 157, Processing Time 0.043 seconds

Conducted Noise Reduction in PFC Boost Converter for Air Conditioner (에어컨용 PFC Boost Convertor의 전도 노이즈 저감)

  • 이성희;김이훈;김영규;원충연;김태덕;김대경
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.5
    • /
    • pp.455-462
    • /
    • 2003
  • Switching PFC converters are widely used not only to comply the power quality specification but also for maximum efficiency. However switching PFC converters generate serious electromagnetic interference(EMI). In this paper to solve this problem, we applied the APW(Anti-Phase Winding) and RPWM(Random PWM) technique to PFC boost converter and obtained good results. Simulation and experimental results show the improved harmonics and reduced EMI effect in air-conditioner system.

Conducted Noise Reduction in PFC Boost Converter for Air Conditioner (에어컨용 PFC Boost Converter의 전도 노이즈 저감)

  • Lee S.H.;Kim L.H.;Kim Y.G.;Won C.Y.;Kim T.D.;Kim D.K.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.793-797
    • /
    • 2003
  • Switching PFC converters are widely used not only to comply the power quality specification but also for maximum efficiency. However switching PFC converters generate serious electromagnetic interference (EMI). In this paper to solve this problem, we applied the APW(Anti Phase Winding) and RPWM(Ran-dom PWM) technique to PFC boost converter and obtained satisfactory results. Simulation and experimental results show the improved harmonic and reduced EMI effect in air-conditioner system.

  • PDF

A New Vector Control Scheme of Brushless DC Motor

  • Park, Sung-Jun;Choo, Young-Bae;Park, Han-Woong;Park, Jin-Ghil;Kim, Cheul-U
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.502-505
    • /
    • 1998
  • In this paper, the new vector control scheme of BLDCM producing loss-minimized ripple-free torque based on the d-q-Ο reference frame is presented including 3 phase unbalanced condition. The optimized phase current wave-forms that are obtained by the proposed method can be a reference values and the motor winding currents are forced to track it by delta modulation technique. As a results, it can be shown that the proposed work provides a simple and clear way to obtain an optimal motor excitation current.

  • PDF

Patterning Barrier Ribs of PDP by Transparent Soft Mold

  • Paek, Sin-Hye;Choi, Hyung-Suk;Park, Lee-Soon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.639-642
    • /
    • 2002
  • A new PDP barrier rib formation technique was investigated utilizing transparent soft maid made of silicon resin. Transparent soft mold was fabricated by pouring a silicone resin into the base mold made with photosensitive glass. The photosensitive barrier rib paste was coated on the glass substrate and dried in a 90 $^{\circ}C$ convection oven for 20min. The transparent soft mold was pressed on top of the semi-dry barrier rib layer and then irradiated with a UV lamp to a total dose of $900{\sim}1000mJ/cm^2$ The soft maid was then removed from the pressed barrier rib by winding up and fine pattern of barrier rib was obtained. The photosensitive barrier rib paste makes the demolding easy due to reduced interfacial forces and shrinking of paste materials.

  • PDF

A Study on An Electronically Compensated Current Sensor for Measurement of Power (전력측정을 위한 전자보상 전류센서에 관한 연구)

  • Park, Y.T.;Kwon, S.W.;Lee, J.H.;Yu, K.M.
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.3
    • /
    • pp.1-8
    • /
    • 1995
  • An electronically compensated current sensor for measurement of power is presented in this paper. An electronic technique which is proposed to design an improved current sensor by means of a feedback winding and an electronic compensation is described. A precision power transducer with a proposed current sensor has been constructed for testing and performance evaluation.

  • PDF

Development of 765kV Shell Type Transformers for Generator Step-up (발전소용 외철형 765kV 변압기 개발)

  • Kim Yungmin;Kim Dogyoon;Joe Gwangje;Bae Yongbae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.12
    • /
    • pp.515-519
    • /
    • 2005
  • We have developed shell type 765kV transformers for generator step-up. Our research and development for shell type 765kV transformers have been continued since 1990. The shell type 765kV transformers of single phase 3MVA for step-up and 500MVA for power transmission were developed in Dec. 1992 and Oct. 1996, respectively. 204MVA 765kV transformer for generator step-up was also developed with the basis of technique and experience to the present. Total 12 phases of 204MVA 765kV transformers will be delivered at Tangjin thermal power plant by 2006. This paper describes electrical and structural features of the shell type 204MVA 765kV transformer.

Evaluation on Insulation Performance of Low-voltage Induction Motors by Partial Discharge Measurement (부분방전 측정에 의한 저압용 유도전동기의 절연성능 평가)

  • Park, Dae-Won;Choi, Su-Yeon;Choi, Jae-Sung;Kil, Gyung-Suk;Lee, Kang-Won
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1887-1891
    • /
    • 2008
  • In this paper, we dealt with a partial discharge (PD) measurement method that has been accepted as an effective and non-destructive technique to estimate insulation performance of low-voltage induction motors. The PD measurement system consists of a coupling network, a low noise amplifier, and associated electronics. A shielded box was used to reduce environmental noise. Frequency characteristic of the coupling network was estimated by a sinusoidal signal input, and the low cut-off frequency of the coupling network was 1 MHz (-3 dB). Also, we carried out a calibration test for the PD measurement system. Sensitivity of the system was of 84 m$V_{max}$/pC between stator winding and enclosure. In application test on a low-voltage three phase induction motor (5 HP), we could detect 88 pC at AC 800 $V_{max}$.

  • PDF

Analysis and Design of a PFC AC-DC Converter with Electrical Isolation

  • Lin, Chia-Ching;Yang, Lung-Sheng;Zheng, Ren-Jun
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.874-881
    • /
    • 2014
  • This study presents a single-phase power factor correction AC-DC converter that operates in discontinuous conduction mode. This converter uses the pulse-width modulation technique to achieve almost unity power factor and low total harmonic distortion of input current for universal input voltage $90V_{rms}$ to $264V_{rms}$) applications. The converter has a simple structure and electrical isolation. The magnetizing-inductor energy of the transformer can be recycled to the output without an additional third winding. The steady-state analysis of voltage gain and boundary operating conditions are discussed in detail. Finally, experimental results are shown to verify the performance of the proposed converter.

Aging Diagnosis of Model Coil of HV Induction Motor Using HFPD and Neural Networks (HFPD 및 신경회로망을 이용한 고압 유도전동기 모델코일 열화진단)

  • Kim, Deok-Geun;Im, Jang-Seop;Yeo, In-Seon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.8
    • /
    • pp.361-367
    • /
    • 2002
  • Many failures in high voltage equipment are preceded by partial discharge activity. In this paper deals with the application of the high frequency partial discharge measurement technique in motorette. HFPD measurement is very effective method to detect the PD occurred in motorette which is the called name of test specimen for accelerating test of stator winding[1] In this study, CT type HFPD sensor is used to detect the partial discharges and a measured HFPD pattern is analyzed by fractal mathematics. The neural network algorithm is used to pattern recognition and ageing diagnosis. As a result of this study, the fractal dimensions are increased along to applied voltage and HFPD pattern recognition using neural network shown excellent recognition rate. Also, the ageing diagnosis of motorette has been Possible.

Steady-State and Transient-State Electromagnetic Analysis of the 30 kVA Superconducting Generator (30 kVA 초전도 발전기의 정상상태 및 과도상태 전자계 해석)

  • Ha, Kyoung-Duck;Hwang, Don-Ha;Park, Doh-Young;Kim, Yong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.91-93
    • /
    • 1998
  • In this paper 30 kVA superconducting generator's transient-state electromagnetic analysis by FEM is described. The transient-state analysis by moving air gap technique was performed to analyze its 3 phase sudden short circuit characteristics. External circuit components were connected to generator model with end-winding resistance and inductance.

  • PDF