Proceedings of the KIEE Conference (대한전기학회:학술대회논문집)
- 1998.07a
- /
- Pages.91-93
- /
- 1998
Steady-State and Transient-State Electromagnetic Analysis of the 30 kVA Superconducting Generator
30 kVA 초전도 발전기의 정상상태 및 과도상태 전자계 해석
- Ha, Kyoung-Duck (KERI, Power Electronics Division, Generator Diagnosis Research Team) ;
- Hwang, Don-Ha (KERI, Power Electronics Division, Generator Diagnosis Research Team) ;
- Park, Doh-Young (KERI, Power Electronics Division, Generator Diagnosis Research Team) ;
- Kim, Yong-Joo (KERI, Power Electronics Division, Generator Diagnosis Research Team)
- 하경덕 (한국전기연구소 전력전자연구부 발전기진단연구팀) ;
- 황돈하 (한국전기연구소 전력전자연구부 발전기진단연구팀) ;
- 박도영 (한국전기연구소 전력전자연구부 발전기진단연구팀) ;
- 김용주 (한국전기연구소 전력전자연구부 발전기진단연구팀)
- Published : 1998.07.20
Abstract
In this paper 30 kVA superconducting generator's transient-state electromagnetic analysis by FEM is described. The transient-state analysis by moving air gap technique was performed to analyze its 3 phase sudden short circuit characteristics. External circuit components were connected to generator model with end-winding resistance and inductance.
Keywords