Browse > Article

Conducted Noise Reduction in PFC Boost Converter for Air Conditioner  

이성희 (성균관대 메카트로닉스공학과)
김이훈 (성균관대 메카트로닉스공학과)
김영규 (성균관대 메카트로닉스공학과)
원충연 (성균관대 전기전자 및 컴퓨터공학부)
김태덕 (삼성전자 DA총괄 DA연구소)
김대경 (삼성전자 DA총괄 DA연구소)
Publication Information
The Transactions of the Korean Institute of Power Electronics / v.8, no.5, 2003 , pp. 455-462 More about this Journal
Abstract
Switching PFC converters are widely used not only to comply the power quality specification but also for maximum efficiency. However switching PFC converters generate serious electromagnetic interference(EMI). In this paper to solve this problem, we applied the APW(Anti-Phase Winding) and RPWM(Random PWM) technique to PFC boost converter and obtained good results. Simulation and experimental results show the improved harmonics and reduced EMI effect in air-conditioner system.
Keywords
PFC Boost Converter; EMI; APW; RPWM;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Reduction of Power Supply EMI Emission by Switching Frequency Modulation /
[ Feng Lin;Dan Y.Chen ] / IEEE Transactions on Power Electronics   ScienceOn
2 RPWM 기법을 이용한 능동 클램프 ZVS 플라이백 컨버터 전도노이즈 저감 /
[ 최태영 ] / 성균관대학교 석사학위논문
3 Novel Boost PFC with Low Common Mode EMI:Modeling and Design /
[ Wu,Win;M.H.Pong;Z.Y.Lu;Z.M.Qian ] / APEC '2000
4 Balanced Switching Converter to reduce Common-Mode Conducted Noise /
[ M.Shoyama;T.Okunae;G.Li;T.Ninomiya ] / IEEE PESC '2001 Record
5 스위칭주파수 변조방식을 이용한 PWM 컨버터의 EMI 저감 /
[ 박석하 ] / 충남대학교 박사학위 논문
6 RPWM 기법을 이용한 능동클램프 ZVS 플라이백 컨버터 전도노이즈 저감 /
[ 김영규;최태영;원충연;김재문;김규식;최세완 ] / 전력전자학술대회 논문집
7 에어컨의 기술개발 동향 및 전망 /
[ 김경화;윤명중 ] / 전력전자학회지   과학기술학회마을