• Title/Summary/Keyword: Winding technique

Search Result 157, Processing Time 0.032 seconds

Improvement of Output Characteristics and Acoustic Noise Characteristics for Single Phase Induction Motor with Concentrated Winding (집중권 방식 단상유도기의 출력 및 소음 특성 개선)

  • Chae, Myong-Gi;Cha, Hyun-Rok;Yun, Cheol-Ho;Jung, Tae-Uk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.693-698
    • /
    • 2007
  • In general the distributed winding method is applied for induction motor in order to have the sinusoidal flux distribution. Recently the concentrated winding method is the interested technique so as to lower the material cost portion of copper coil. In the concentrated winding induction motor the harmonic flux and the torque deterioration by it would be occurred. To restrain ill effect of harmonic flux distribution by concentrated winding, the skew of rotor conduction bar is very important design variable. This study is focused on the optimal design of rotor bar's skew and winding turns for concentrated winding induction motor. In this study, the control method of harmonic parasitic torque in concentrated winding induction motor is proposed and validated its practicality through the experiment. As a result of this study, large skew angle which was not conventional in distributed winding was favorable in the concentrated winding induction motor. The concentrated winding induction motor which is designed per the proposed method of this study can be manufactured more cost effectively than conventional distributed winding.

Feature Extraction for Fault Signals of High Voltage Motor Stator Windings (고압전동기 결함신호의 특징추출에 관한 연구)

  • Park, Jae-Jun;Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1154-1157
    • /
    • 2004
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in imitation stator winding of high voltage motors. The motor was energized to 4.47kV, 6.67, respectively. Applied voltage to Imitation winding was used two voltage level, 4.47[KV]and 6.67[KV]. Motors having imitation stator winding were installed with 80pF capacitive couplers at the terminal box Case of PD Pattern regarding applied voltage phase angel, the PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). As the result, we could discrimidate using TGA the difference of internal and surface discharge for imitation stator winding. We have used the other technique, in order to feature extraction of faulty signals on stator winding, Daubechies Discrete wavelet transform and Harmonics analysis(FFT) about faulty signals.

  • PDF

A Study on Feature Extraction of Fault Signal for Stator Winding using Epoxy/Mica Coupler (에폭시/마이카 커플러를 이용한 고정자권선 결함신호 특징추출에 관한연구)

  • Park, Jae-Jun;Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.225-226
    • /
    • 2005
  • In this Study, we have acquired 5-simulation Fault types Signals of high voltage Motor stator winding using epoxy/mica coupler. In order to know stator winding fault type using fault signals, we have performed feature extraction to apply wavelet transform technique. we have obtained skewness and kurtosis as statistical parameters of fault signal pattern from non deterioration state winding. We have know that 5 fault signals types have done an exponential function pattern shape but individually fault a class widely was different each other a signal waveform of pattern.

  • PDF

Experimental study on bobbin contact for HTS motor field winding (고온초전도 계자권선의 보빈 접촉법에 대한 실험적 연구)

  • 김석환;손명환;백승규;조영식;서무교;이언용;권영길
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.297-299
    • /
    • 2002
  • To wind a HTS (High Temperature Superconductor) tape conductor on a bobbin, double pancake winding technique is widely used to reduce number of splicing contacts between conductor pieces. However, this makes some Ic (critical current) degradation on kink points which is unavoidable. This paper describes the two ways of winding; usual double pancake and soldered double pancake. Characteristics of the two windings are measured and compared.

  • PDF

Driving Characteristics of SRM with an Auxiliary Fully Pitched Winding

  • Jung, Tae-Uk;Oh, Seok-Gyu;Ahn, Jin-Woo;Hwang, Young-Moon
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.763-767
    • /
    • 1998
  • In this paper, we analyzed the characteristics and source of vibration and acoustic noise in SRM drives. The paper study the reduction technique of those by new SRM which has auxiliary field winding. The operating mechanism and vibration and acoustic noise characteristics is examined. This paper suggests the control strategies of auxiliary field winding in order to reduce vibration and acoustic noise.

  • PDF

Novel Topology and Control Strategy of HVDC Grid Connection for Open Winding PMSG based Wind Power Generation System

  • Zeng, Hengli;Nian, Heng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.215-221
    • /
    • 2014
  • To satisfy the high voltage direct current (HVDC) grid connection demand for wind power generation system, a novel topology and control strategy of HVDC grid connection for open-winding permanent magnet synchronous generator (PMSG) based wind power generation system is proposed, in which two generator-side converter and two isolated DC/DC converters are used to transmit the wind energy captured by open winding PMSG to HVDC grid. By deducing the mathematic model of open winding PMSG, the vector control technique, position sensorless operation, and space vector modulation strategy is applied to implement the stable generation operation of PMSG. Finally, the simulation model based on MATLAB is built to validate the availability of the proposed control strategy.

Study on Distortion Ratio Calculation of Park's Vector Pattern for Diagnosis of Stator Winding Fault of Induction Motor (유도전동기의 고정자 권선고장 진단을 위한 팍스벡터 패턴의 왜곡률 연산에 대한 연구)

  • Yang, Chul-Oh;Park, Kyu-Nam;Song, Myung-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.643-649
    • /
    • 2012
  • The diagnosis technique of stator winding faults based on Motor Current Signature Analysis(MCSA) was suggested. Park's vector pattern, the circle that is drawn by d-q transformed currents($i_d$, $i_q$), is widely used for stator winding faults detection. The current Distortion Ratio(DR), defined by the ratio of max axis and min axis of ellipse of Park's vector's pattern, was more simple and powerful method than the Park's vector pattern. In this study, a calculation method of distortion ratio of Park's vector pattern was suggested for auto diagnosis of stator winding short fault and usefulness of suggested calculation method of distortion ratio was verified through simulation using LabVIEW program.

A Study on the Partial Discharge Wave Propagation along Stator Winding (회전기 권선의 펄스 전송특성 연구)

  • Kang, Dong-Sik;Sim, Woo-Yong;Hwang, Don-Ha;Kim, Yong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.738-740
    • /
    • 2003
  • A lot of R&D on the diagnosis of stator winding insulation for large rotating machines has been carried out since the 1970s. The on-line partial discharge measurement has proved to be an effective technique in the evaluation of the state of stator insulation in high voltage rotating machines. It is well known that if the discharge pulses propagate through the winding conductor, they are attenuated and delayed. In the present study, to investigate the attenuation and the time delay of discharge pulses through the winding conductor, a series of tests were conducted using a model coils and slot. Thus it could be concluded that while the high frequency pulse propagates in radiation or end-winding coupling modes, the low frequency one does in a series mode through the coil conductor.

  • PDF

Analysis of Impulse Response of Power Transformer using Electric Equivalent Circuit (등가회로를 이용한 전력용 변압기의 과도응답 특성 해석)

  • Chang, Kyung-Woon;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.97-99
    • /
    • 1998
  • This paper presents a numerical study of the behavior of the transformer winding, when stressed by the standard impulse voltage. The mathematical model of the transformer takes several points into the account. Capacitance of not adjacent winding as well as adjacent winding, eddy current loss caused by self and mutual inductance given as the functions of frequency. Not like the previous approach where calculation of capacitance is performed, in average sense. In this paper, capacitance of both adjacent and not adjacent winding is calculated using the numerical approach(B.E.M.), so they can get the more accurate value of capacitance. Because of frequency dependency of inductance, numerical-laplace-transform technique is required. Finally, to validate this approach, a simple test winding is simulated.

  • PDF

A study on Quench Characteristics considering Winding Tension in Superconducting Coil using Acoustic Emission Technique (권선장력을 고려한 초전도 계자코일의 퀀치특성 및 AE 신호특성에 관한 연구)

  • 이준현;이민래;손명환;권영길
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.2
    • /
    • pp.8-14
    • /
    • 1999
  • In this study, acoustic emission(AE) technique has been applied to detecting quench which is one of the serious peoblems to assure the integrity of superconducting coil at cryogenic temperature. The characteristics of AE parameters have been analyzed by correlating with the number of quenches, whinding tension of superconducting coil and charge rate of transport current. The quench localization was also performed using AE signals and there was also good correlation between quench current and AE parameters such as AE energy and AE events. In this study, it was confirmed that AE signals were mainly due to the conductor motion which caused by premature quenching. It was also found that optimized winding tension at superconducting coil was needed to prevent quench caused by conductor motion.

  • PDF