Study on Distortion Ratio Calculation of Park's Vector Pattern for Diagnosis of Stator Winding Fault of Induction Motor  

Yang, Chul-Oh (순천대학교 공대 전기공학과)
Park, Kyu-Nam (순천대학교 공대 전기제어공학과)
Song, Myung-Hyun (순천대학교 공대 전기제어공학과)
Publication Information
The Transactions of The Korean Institute of Electrical Engineers / v.61, no.4, 2012 , pp. 643-649 More about this Journal
Abstract
The diagnosis technique of stator winding faults based on Motor Current Signature Analysis(MCSA) was suggested. Park's vector pattern, the circle that is drawn by d-q transformed currents($i_d$, $i_q$), is widely used for stator winding faults detection. The current Distortion Ratio(DR), defined by the ratio of max axis and min axis of ellipse of Park's vector's pattern, was more simple and powerful method than the Park's vector pattern. In this study, a calculation method of distortion ratio of Park's vector pattern was suggested for auto diagnosis of stator winding short fault and usefulness of suggested calculation method of distortion ratio was verified through simulation using LabVIEW program.
Keywords
Distortion ratio calculation; Induction motor; Diagnosis; Stator winding fault; Park's vector;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 한민관, 우혁재, 송명현, 박규남, "주파수 해석 방법에 의한 유도전동기의 고정자 권선 고장 진단," 대한전기학회 하계학술대회 논문집, pp.2313-2315, 2002년 7월.
2 G. B. Kliman, W. J. Premerlani, R. A. Koegl, and D. Hoeweler "A new approach to on-line turn fault detection in AC motors," Conference Records IEEE-IAS Annual Meeting, vol.1, pp.687-693, 1996.
3 J. Sottile. and J.L. Lohler, "An on-line method to detect incipient failure of tyrn insulation in random-wound motors," IEEE Transactions on Energy Conversion vol. 28. no.5 pp.1109-1117, September/October 1992.
4 Sang-Bin Lee, R. M Tallam, T. G Habetler, "A robust, on-line turn-fault detection technique for induction machines based on monitoring the sequence component impedance matrix", Power Electronics Specialists Conference, 2001. PESC. IEEE 32nd Annual, vol 4, pp. 2217-2223, June 2001.
5 A.J.M. Cardoso, S.M.A Cruz, D.S.B Fonseca, "Inter turn stator winding fault diagnosis in three phase induction motors, by Park's Vector Approach," IEEE Trans. vol. 14 no.3, pp.595-598, Sept. 1999.
6 한민관, 우혁재, 송명현, 박규남, "Park's Vector 기법을 이용한 소형 3상 유도전동기의 권선고장 진단," 대한전기학회 하계학술대회 논문집, pp.2070-2072, 2003년 7월.
7 송명현, 박규남, 한동기, 우혁재, "LabVIEW를 이용한 소형 유도전동기의 권선고장 자동진단," Trans. KIEE vol. 55p, no. 4. 2006년 12월
8 송명현, 박규남, 한동기, 양철오, "Park's 벡터 패턴의 왜곡률을 이용한 고정자 권선 고장 자동진단," Trans. KIEE. vol. 57p, no. 2, 2008.   과학기술학회마을
9 양철오, 김종선, 김준영, 박규남, 송명현, "유도전동기의 권선 단락고장 자동진단을 위한 팍스벡터 패턴의 왜곡률 분석," 광주전남지역 전기학회 합동 추계학술대회 논문집, pp.9-12, 2010년 12월
10 양철오, 김종선, 김준영, 박규남, 송명현, "유도전동기 권선 단락 상에 따른 팍스 벡터 패턴 왜곡률의 영향 해석," 대한전기학회 하계학술대회 논문집, pp.2075-2076, 2011년 7월.
11 S. Williamson, and K. Mirzoian, "Analysis of cage induction motors with stator winding fault," IEEE Transactions on Power Apparatus and Systems, vol. PAS-104, no. 7, pp. 1838-1842, July 1985.   DOI   ScienceOn
12 J Penman, H.G. Sendding. B. A Lloyd, and W.T Fink. "Detection and location of interturn short circuit in the stator windings of operating motors," IEEE Transactions of Energy Conversion. vol.9 no.4 pp.652-658, December 1994.   DOI   ScienceOn
13 R. A. Leonhard, and W. T. Thompson, "Vibration and stray flux monitoring for unbalanced supply and inter-turn winding fault diagnosis in induction machines," British Joural of Nondestructive testing. pp.211-215, July 1986.