• 제목/요약/키워드: Winding simulation

검색결과 291건 처리시간 0.028초

중전압 계통 연계를 위한 멀티 센트럴 대용량 태양광 발전 시스템의 공통 모드 전압 억제 (Suppression of Common-Mode Voltage in a Multi-Central Large-Scale PV Generation Systems for Medium-Voltage Grid Connection)

  • 배영상;김래영
    • 전력전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.31-40
    • /
    • 2014
  • This paper describes an optimal configuration for multi-central inverters in a medium-voltage (MV) grid, which is suitable for large-scale photovoltaic (PV) power plants. We theoretically analyze a proposed common-mode equivalent model for problems associated with multi-central transformerless-type three-phase full bridge(3-FB) PV inverters employing two-winding MV transformers. We propose a synchronized PWM control strategy to effectively reduce the common-mode voltages that may simultaneously occur. In addition, we propose that the existing 3-FB topology may also have the configuration of a multi-central inverter with a two-winding MV transformer by making a simple circuit modification. Simulation and experimental results of three 350kW PV inverters in a multi-central configuration verify the effectiveness of the proposed synchronization control strategy. The modified transformerless-type 3-FB topology for a multi-central PV inverter configuration is verified using an experimental prototype of a 100kW PV inverter.

IGBT PWM 인버터 구동 유도전동기 고정자 권선에서의 과도전압 분포특성 (Distribution Characteristics of Irregular Voltage in Stator Windings of IGBT PWM Inverter-Fed Induction Motors)

  • 황돈하;김용주;이인우;배성우;김동희;노체균
    • 전력전자학회논문지
    • /
    • 제8권4호
    • /
    • pp.351-358
    • /
    • 2003
  • 본 논문에서는 IGBT PWM 인버터 구동 유도전동기 고정자 권선에서의 스위칭 써지전압 분포특성을 분석하였다. 고정자 권선의 턴 및 코일간의 전압분포를 해석하기 위하여 케이블을 포함한 유도전동기의 등가모델을 제안하고, 유한요소법을 이용하여 고주파 파라메타를 산출하였다 또한, 유도전동기, IGBT PWM 인버터 및 케이블등에 대한 전체 시스템의 EMTP 시뮬레이션을 통하여 인버터 상승시간, 케이블 길이 및 스위칭 주파수 등의 영향에 따른 전압분포를 분석하였다. 380[V], 50[HP] 유도전동기 고정자 권선을 대상으로 한 전압분포 특성실험을 통하여 인버터용 전동기 설치 및 과전압 억제용 필터 설계시의 유용한 자료를 제시하였다.

에너지 변환 이론에 의한 직선형 피스톤 액추에이터의 권선부 인가 전압의 특성 해석 (Analysis of the Voltage Characteristics Applied to a Actuator Winding by Electromechanical Energy Conversion Theory)

  • 김양호;손웅태;황석영
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.469-472
    • /
    • 2004
  • 본 논문에서는 직선형 피스톤 액추에이터의 응용모델을 제안하고 이를 구현하였다. 구성된 액추에이터의 해석을 위해서 패러데이 법칙으로부터 기본 방정식을 유도하였고, 이를 바탕으로 소형, 경량, 고속 응답을 요구하는 시스템에 적용 가능한 실험적 자료를 얻었다. 또한 본 논문에서는 자계로부터 일반적으로 구할 수 있는 전자기력을 에너지 변환 이론적 관점에서 기계 방정식과 결합하고 전원 공급부의 인가 전압의 변화로부터 액추에이터에 나타나는 현상을 Matlab 프로그램을 활용하여 간접적 방법으로 고찰하였다. 그 결과는 실제적인 설계에 적용할 경우 설계 프로그램의 자료나 부분적 변경시 참조 할 수 있으리라 사료된다. 이 결과를 바탕으로 Linear Actuator MfdBl 시스템과 구현된 직선형 피스톤 액추에이터의 동작이 실제 시스템에 활용될 수 있는 방법으로 가능함을 검증할 수 있었다.

  • PDF

50[kVA] 몰드변압기 권선부의 열전달 특성 해석 (Analysis on Thermal Transfer Characteristics of 50 kVA Mold-Transformer)

  • 이현진;정중일;허창수;조한구
    • 조명전기설비학회논문지
    • /
    • 제16권3호
    • /
    • pp.47-54
    • /
    • 2002
  • 본 논문은 단상 50[kVA] 몰드변압기 권선부의 열전달 특성에 대한 연구 결과이다. 1차 권선의 열전도도는 권선을 이루고 있는 물질 비 즉, 1차 권선의 절연을 담당하는 다량의 에폭시 수지와 그에 비해 소량의 구리 도선을 고려하여 결정하였다. 반면에 2차 권선의 경우 구성 성분은 다량의 구리도선과 절연을 담당하는 소량의 에폭시 수지로 되어 있다. 2차 권선 열전도도는 질량 비로서 결정될 수 없기 때문에 2차 권선의 열전도도값은 시작품의 측정 최고온도와 FEM을 이용한 분석결과를 비교하여 결정하였다. 각 권선부의 물리적 특징을 고려하여 상용 프로그램을 통해 시뮬레이션 모델을 만들었다. 본 연구결과를 바탕으로 몰드변압기 권선부에 Hole이 존재할 때와 안할 때 각각에 대해 주위온도·풍속변화에 따른 최고온도 변화를 고찰하였다.

BLDC 모터의 열적 성능에 대한 설계 인자의 영향 (Effects of Design Parameters on the Thermal Performance of a Brushless DC Motor)

  • 김민수;이관수
    • 대한기계학회논문집B
    • /
    • 제32권2호
    • /
    • pp.141-148
    • /
    • 2008
  • A numerical simulation of brushless DC motor is performed to elucidate thermo-flow characteristics in winding and bearing with heat generation. Rotation of rotor and blades drives influx of ambient air into the rotor inlet. Recirculation zone exists in the tiny interfaces between windings. The flow separation causes poor cooling performance in bearing part and therefore the redesign of the bearing groove is required. The design parameters such as the inlet location, geometry and bearing groove threshold angle have been selected in the present simulation. As the inlet location moves inward in the radial direction, total incoming flow rate and heat transfer rate are increased. Total incoming flow rate is increased with increasing the inlet inner length. The effect of the bearing groove threshold angle on the thermal performance is less than that of other design parameters.

단상 SRM의 고속 구동 제어에 관한 연구 (The High-speed Operation of Single Phase Switched Reluctance Motor)

  • 안준선;이주
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권10호
    • /
    • pp.470-476
    • /
    • 2005
  • In this paper PU control scheme is presented. The proposed scheme has following features. The one is oft-starting method which is used for preventing to flow large current in motor phase winding when motor starts. The ther is the selection of the level of the over current. The first feature is implemented by increasing the PWM duty lowly, the second feature is implemented by limiting the magnitude of the phase current level by which the over heat f motor by copper losses and magnetic saturation decreases. By the analysis using FEM considering load condition, the peed of mode transition from PW to single pulse control is selected and confirmed by simulation that there is no ver current occurs during the mode transition. For the verification of proposed scheme, the simulation using MATLAB Simulink with considering non-linearity of inductance profile from FEM analysis is performed and the experiment with SRM drive system which has the DSP controller and single Phase SRM are peformed.

직동식 공압서보밸브의 Force Motor 설계 및 성능시험 (Design and Performance Test of the Force Motor for Direct Drive-type Pneumatic Servo Valve)

  • 이원희;김동수;박상운
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.836-839
    • /
    • 2003
  • A pneumatic servo valve which is widely applied in industrial field. And It is consist of force motor, spool & sleeve and servo controller. In this study. we developed the force motor which is consume to low power for a pneumatic servo valve. We could reduce the number of turn of the solenoid by using ferromagnetic permanent magnet and took different direction of each other using one coil instead of two coil. we modeled a system consisting of various electro-mechanical subsystems. The appropriateness of the model was verified by simulation. The simulation model resolved the motion of spool, the winding current and the magnetic force. Also, we calculated the displacement and velocity of the spool, flux contour line, b vector. flux density. flux linkage, back EMF etc.

  • PDF

PSCAD를 이용한 전력용 변압기 모델링과 과도 해석 (Power Transformer Modeling and Transient Analysis using PSCAD)

  • 박철원
    • 전기학회논문지P
    • /
    • 제65권2호
    • /
    • pp.122-129
    • /
    • 2016
  • Current differential protection relaying with second harmonic restraint is the main protection for large capacity power transformer. PSCAD simulation program is widely used for modeling of dynamic varying transients phenomena. This paper deals with a power transformer model and transients analysis using PSCAD software to develop IED for power transformer. Simulation was carried out using a three phase 40MVA, 154/22.9kV, 60Hz, two-winding transformer with Y-Y connection used in actual fields. The paper analyzed transformer magnetizing inrush, external fault, and internal fault conditions with this model in the time domain. In addition, we performed an analysis in the frequency domain using FFT during several conditions.

공기압 Servo Valve 설계 및 해석 (The Analysis and Design of Electro-pneumatic Servo Valve)

  • 고진호;류동렬;이주호;김영석;김동수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1210-1214
    • /
    • 2008
  • Electro-pneumatic servo valve is an electro-mechanical device which converts electric signal into pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristic, no air leakage at null, and can be fabricated at a low-cost. The first objective of this research is to design and fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In this paper, we has been modeled as a system consisting of coupled electro-mechanic and mechanical subsystems. The appropriateness of the model has been verified by simulation. The simulation model resolves the valve body motion and the solenoid current at high accuracy. Also, we are calculate the displacement of spool and computed results show winding currents, magnetic actuator force, flux density line, displacement, velocity, back EMF, eddy current etc.

  • PDF

고온초전도동기모터의 시변자계에 따른 회전자의 손실 해석에 관한 연구 (A Study on the Analysis for Electrical Losses of the Rotor considering Time Varying Field of High Tc Superconducting Synchronous Motor)

  • 송명곤;윤용수;장원갑;장인배;이상진;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.340-342
    • /
    • 1998
  • This paper presents the ac losses simulation in the rotor having an high-Tc superconducting field winding using Ag sheathed Bi-2223. The analysis was conducted with an equivalent model of the high-Tc superconducting motor under transition condition during the load that varies from 250watt to 500watt. The simulation results show that the transient state lasts for about 2 seconds, and the ac losses decreased exponentially from the initial value above 2 watts.

  • PDF