• Title/Summary/Keyword: Width-to-thickness ratio

Search Result 462, Processing Time 0.028 seconds

Upper Garment Sizing System for Obese School Boys Based on Somatotype Analysis (학령후기 비만 남아의 체형 분석에 따른 plus-size 남자 아동복 상의 치수 규격 제안)

  • Park, Soon-Jee
    • Journal of the Korean Home Economics Association
    • /
    • v.46 no.9
    • /
    • pp.99-112
    • /
    • 2008
  • The increasing rate of obesity in school aged children has become a conspicuous social phenomenon in Korea. This has been linked to greater economic growth, increasingly westernized dietary habits, and a consumer driven society. Given that obesity can lead to social exclusion or unfavorable attention by other students in a school setting, the design of plus-size garments have become important for effective appearance management skills. This research aimed to establish a somatotype database for obese school boys, aged 10 to 12, in order to develop a sizing system for plus-size upper garments. In order to measure somatotype of average and obese school boys, five categories were recorded; height, obesity, length of trunk, thickness of neck and chest. For obese boys, subcutaneous fat thickness and position of B.P/shoulder point factors were recorded. Obesity factor was subdivided into overall and specific ones, and while the deviation of obese body types was severe compared to the average type. Obese body type showed significantly higher measurements in width, girth, thickness. This is linked to the fact that the frequency ratio of obesity increases with age. Stature and chest were chosen as control dimensions for boys' wear. As crosstabulation of stature(5cm interval) and chest girth(2, 3 and 4cm), and stature(5cm interval)/chest girth(3cm interval) sizing system showed, the most effective cover ratio and adaptability to the data distribution $25{\sim}75$ quartile. Based on the findings, 10 sizes were formulated for average body type, while 18 sizes were formulated for obese type, whose size cover ratios were 48% and 62.9%, respectively. The primary ranges of stature were $145cm{\sim}150cm$, while those of chest girth were $79{\sim}82cm$. Each size was declared as "chest-somatotype{A(average)/O(obesity)-stature". This study proposed a plus-size upper garment sizing systems for obese boys, accompanied with reference measurements for suit, casual wear and underwear. The finding showed that the two systems were totally separate and not overlapping, meaning that plus-size sizing system is essential for obese school boys. The obesity type system had more size and wider range specs.

Analysis of stress and distortion that develop during accelerated cooling of plate (가속냉각시 강판에 발생하는 응력 및 변형에 대한 연구)

  • 김호영;김창영;주웅용;장래웅
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.952-958
    • /
    • 1988
  • To analyze the nonflatness and residual stress in accelerated cooled plate, a numerical analysis model has been developed. Two factors, i.e. temperature and phase transformation, are considered in calculating the stress distribution that develops during cooling. The plastic strain and plate-buckling, which are often shown in accelerated cooled plate, were determined from this stress. Mean temperature in through thickness direction and temperature difference in width direction are considered in the model to simplify the calculation. The temperature and stress distribution changes caused by phase transformation are involved in terms of the effective specific heat and the effective thermal expansion coefficient. With the model, accelerated cooling of 10mm(t) $^{*}$3000mm(w) plate was simulated. The condition of accelerated cooling was .deg. C/sec from just after hot rolling to 500.deg. C. The initial temperature-difference ratio, .DELTA.Tr, in width direction is an important factor in evaluating the stress distribution. When .DELTA.Tr is 0.08, buckling occurs during cooling and 7kgf/m $m^{2}$ of residual stress develops at the edge of plate. To secure the flatness, .DELTA.Tr should be less than 0.07. Small scaled cooling test was conducted to verify the exactness of the model and the results proved the usefulness of this numerical analysis model.l.

Machine learning techniques for prediction of ultimate strain of FRP-confined concrete

  • Tijani, Ibrahim A.;Lawal, Abiodun I.;Kwon, S.
    • Structural Engineering and Mechanics
    • /
    • v.84 no.1
    • /
    • pp.101-111
    • /
    • 2022
  • It is widely known that axially loaded fiber-reinforced polymer (FRP) confined concrete presents significant and enhanced mechanical properties with reference to the unconfined concrete. Therefore, to predict the mechanical behavior of FRP-confined concrete two quantities-peak strength and ultimate strain are required. Despite the significant advances, the determination of the ultimate strain of FRP-confined concrete is one of the most challenging problems to be resolved. This is often attributed to our persistence in desiring the conventional methods as the sole technique to examine this phenomenon and the complex nature of the ultimate strain of FRP-confined concrete. To bridge the research gap, this study adopted two machine learning (ML) techniques-artificial neural network (ANN) and Gaussian process regression (GPR)-to analyze observations obtained from 627 datasets of FRP-confined concrete circular and non-circular sections under axial loading test. Besides, the techniques are also used to predict the ultimate strain of FRP-confined concrete. Seven parameters namely width/diameter of the specimens, corner radius ratio, the strength of concrete, FRP elastic modulus, FRP thickness, FRP tensile rupture strain, and the axial strain of unconfined concrete-are the input parameters used to predict the ultimate strain of FRP-confined concrete. The results of the current study highlight the merit of using AI techniques in structural engineering applications given their extraordinary ability to comprehend multidimensional phenomena of FRP-confined concrete structures with ease, low computational cost, and high performance over the existing empirical models.

Finite element modelling and design of partially encased composite columns

  • Chicoine, Thierry;Tremblay, Robert;Massicotte, Bruno
    • Steel and Composite Structures
    • /
    • v.2 no.3
    • /
    • pp.171-194
    • /
    • 2002
  • In this paper, the behaviour of axially loaded partially encased composite columns made with light welded H steel shapes is examined using ABAQUS finite element modelling. The results of the numerical simulations are compared to the response observed in previous experimental studies on that column system. The steel shape of the specimens has transverse links attached to the flanges to improve its local buckling capacity and concrete is poured between the flanges only. The test specimens included 14 stubcolumns with a square cross section ranging from 300 mm to 600 mm in depth. The transverse link spacing varied from 0.5 to 1 times the depth and the width-to-thickness ratio of the flanges ranged from 23 to 35. The numerical model accounted for nonlinear stress-strain behaviour of materials, residual stresses in the steel shape, initial local imperfections of the flanges, and allowed for large rotations in the solution. A Riks displacement controlled strategy was used to carry out the analysis. Plastic analyses on the composite models reproduced accurately the capacity of the specimens, the failure mode, the axial strain at peak load, the transverse stresses in the web, and the axial stresses in the transverse links. The influence of applying a typical construction loading sequence could also be reproduced numerically. A design equation is proposed to determine the axial capacity of this type of column.

Buckling analysis of FGM Euler-Bernoulli nano-beams with 3D-varying properties based on consistent couple-stress theory

  • Hadi, Amin;Nejad, Mohammad Zamani;Rastgoo, Abbas;Hosseini, Mohammad
    • Steel and Composite Structures
    • /
    • v.26 no.6
    • /
    • pp.663-672
    • /
    • 2018
  • This paper contains a consistent couple-stress theory to capture size effects in Euler-Bernoulli nano-beams made of three-directional functionally graded materials (TDFGMs). These models can degenerate into the classical models if the material length scale parameter is taken to be zero. In this theory, the couple-stress tensor is skew-symmetric and energy conjugate to the skew-symmetric part of the rotation gradients as the curvature tensor. The material properties except Poisson's ratio are assumed to be graded in all three axial, thickness and width directions, which it can vary according to an arbitrary function. The governing equations are obtained using the concept of minimum potential energy. Generalized differential quadrature method (GDQM) is used to solve the governing equations for various boundary conditions to obtain the natural frequencies of TDFG nano-beam. At the end, some numerical results are performed to investigate some effective parameter on buckling load. In this theory the couple-stress tensor is skew-symmetric and energy conjugate to the skew-symmetric part of the rotation gradients as the curvature tensor.

Design of a Broadband Series-Fed Bow-tie Dipole Pair Antenna for Mobile Base Station (이동통신 기지국용 광대역 직렬 급전 보우타이 다이폴 쌍 안테나 설계)

  • Yeo, Junho;Lee, Jong-Ig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1445-1450
    • /
    • 2013
  • In this paper, a broadband series-fed bow-tie dipole pair (SBDP) antenna operating in the band of 1.7-2.7 GHz for mobile communication base station applications is proposed. The proposed antenna uses bow-tie-shaped dipole elements instead of straight strip dipole ones used in a conventional series-fed dipole pair (SDP) antenna. The simulation results show that the lowest operating frequency is shifted toward lower frequency as the flare angle increases, and so the lengths of the bow-tie dipole elements can be reduced in proportion to the frequency shift toward lower frequency. An SBDP antenna with a flare angle of 10 degrees is fabricated on an FR4 substrate (dielectric constant = 4.4 and thickness = 1.6 mm) and total width of the fabricated antenna is reduced by 10% compared to that of the conventional SDP antenna. The measured impedance bandwidth for voltage standing wave ratio (VSWR) < 2 is 48.8% (1.69-2.78 GHz), gain is 5.8-6.3 dBi, and the front-to-back ratio (FBR) is 14-17 dB.

Effect of Pass Schedule on the Microstructures and Mechanical Properties of Multi-step Cold Rolled High Carbon Steel Wires (다단계 냉간 압연된 고탄소강 와이어의 미세조직 및 기계적 특성에 미치는 패스스케줄의 영향)

  • Woo, Dong-Hyeok;Lee, Wook-Jin;Park, Ik-Min;Park, Yong-Ho
    • Korean Journal of Materials Research
    • /
    • v.21 no.6
    • /
    • pp.320-326
    • /
    • 2011
  • Flat rolling of wire is an industrial process used to manufacture electrical flat wire, medical catheters, springs, piston segments and automobile parts, among other products. In a multi-step wire flat rolling process, a wire with a circular crosssection is rolled at room temperature between two flat rolls in several passes to achieve the desired thickness to width ratio. To manufacture a flat wire with a homogeneous microstructure, mechanical and metallurgical properties with an appropriate pass schedule, this study investigated the effect of each pass schedule (1stand ~ 4stand) on the microstructures, mechanical properties and widths of cold rolled high carbon steel wires using four-pass flat rolling process. The evolutions of the microstructures and mechanical properties of the widths of cold rolled wires during three different pass schedules of the flat rolling process of high carbon wires were investigated, and the results were compared with those for a conventional eight-pass schedule. In the width of cold rolled wires, three different pass schedules are clearly distinguished and discussed. The experimental conditions were the same rolling speed, rolling force, roll size, tensile strength of the material and friction coefficient. The experimental results showed that the four-pass flat cold rolling process was feasible for production of designed wire without cracks when appropriate pass schedules were applied.

Importance of Relative Comparison of Capsular Widths on the Affected and Non-Affected Sides of Temporomandibular Joint Arthralgia Patients: An Ultrasonography Study

  • Hee-Won Kim;Yong-Woo Ahn;Sung-Hee Jeong;Soo-Min Ok;Hye-Mi Jeon;Hye-Min Ju
    • Journal of Oral Medicine and Pain
    • /
    • v.48 no.3
    • /
    • pp.106-111
    • /
    • 2023
  • Purpose: In this study, we evaluate the potential of the relative ratio of capsular width (RCW) between the affected side (Aff) and non-affected side (Non-aff) in patients with temporomandibular joint (TMJ) arthralgia. We assessed whether RCW may hold greater diagnostic significance than the objective capsular width (CW) reported in previous studies when diagnosing arthralgia using ultrasonography (US). Methods: Forty-nine patients were assessed using US, excluding four patients with bilateral arthralgia. The patients were divided into two groups: 40 with unilateral arthralgia (UA), and nine without arthralgia (NA). We measured CW and masseter muscle thickness using US. Moreover, we employed RCW to analyze the variances between the groups. The numerical rating scale (NRS) and RCW were compared before and after dexamethasone injection in 10 patients who underwent follow-up evaluations. Results: Within the UA group, CW on the Aff was found to be significantly larger compared to the Non-aff (p<0.001). Additionally, RCW in the UA group was greater than that in the NA group (p<0.01). Furthermore, after dexamethasone injection, a reduction in the NRS and RCW values was observed in the 10 patients who were followed up. Conclusions: While previous studies have suggested a link between arthralgia and TMJ effusion, making CW a possible indirect diagnostic indicator for arthralgia, our findings propose that RCW could hold more diagnostic value than objective CW. However, additional studies are required to standardize the protocols for interpreting US results and determining the cutoff value of RCW in diagnosing TMJ arthralgia.

Out-of-plane buckling and bracing requirement in double-angle trusses

  • Chen, Shaofan;Su, Mingzhou
    • Steel and Composite Structures
    • /
    • v.3 no.4
    • /
    • pp.261-275
    • /
    • 2003
  • Truss members built-up with double angles back-to-back have monosymmetric cross-section and twisting always accompanies flexion upon the onset of buckling about the axis of symmetry. Approximate formulae for calculating the buckling capacity are presented in this paper for routine design purpose. For a member susceptible only to flexural buckling, its optimal cross-section should consist of slender plate elements so as to get larger radius of gyration. But, occurrence of twisting changes the situation owing to the weakness of thin plates in resisting torsion. Criteria for limiting the leg slenderness are discussed herein. Truss web members in compression are usually considered as hinged at both ends for out-of-plane buckling. In case one (or both) end of member is not supported laterally by bracing member, its adjoining members have to provide an elastic support of adequate stiffness in order not to underdesign the member. The stiffness provided by either compression or tension chords in different cases is analyzed, and the effect of initial crookedness of compression chord is taken into account. Formulae are presented to compute the required stiffness of chord member and to determine the effective length factor for inadequately constrained compressive diagonals.

Bearing Strength of Hybrid Coupled Shear Wall Connections

  • Park Wan-Shin;Yun Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.1065-1074
    • /
    • 2005
  • Due to lack of information, current design methods to calculate bearing strength of connections are tacit about cases in which hybrid coupled walls have connection details of stud bolts and horizontal ties. In this study, analytical study was carried out to develop model for calculating the connections strength of embedded steel section. The bearing stress at failure in the concrete below the embedded steel coupling beam section is related to the concrete compressive strength and the ratio of the width of the embedded steel coupling beam section to the thickness of the shear walls. Experiments were carried out to determine the factors influencing the bearing strength of the connection between steel coupling beam and reinforced concrete shear wall. The test variables included the reinforcement details that confer a ductile behavior in connection between steel coupling beam and shear wall, i. e., the auxiliary stud bolts attached to the steel beam flanges and the transverse ties at the top and the bottom steel beam flanges. In addition, additional test were conducted to verify the strength equations of the connection between steel coupling beam and reinforced concrete shear wall. The results of the proposed equations in this study are in good agreement with both our test results and other test data from the literature.