DOI QR코드

DOI QR Code

Bearing Strength of Hybrid Coupled Shear Wall Connections

  • Park Wan-Shin (Dept. of Civil and Environmental Engineering, University of Cincinnati) ;
  • Yun Hyun-Do (Dept. of Architectural engineering, Chungnam National University)
  • 발행 : 2005.12.01

초록

Due to lack of information, current design methods to calculate bearing strength of connections are tacit about cases in which hybrid coupled walls have connection details of stud bolts and horizontal ties. In this study, analytical study was carried out to develop model for calculating the connections strength of embedded steel section. The bearing stress at failure in the concrete below the embedded steel coupling beam section is related to the concrete compressive strength and the ratio of the width of the embedded steel coupling beam section to the thickness of the shear walls. Experiments were carried out to determine the factors influencing the bearing strength of the connection between steel coupling beam and reinforced concrete shear wall. The test variables included the reinforcement details that confer a ductile behavior in connection between steel coupling beam and shear wall, i. e., the auxiliary stud bolts attached to the steel beam flanges and the transverse ties at the top and the bottom steel beam flanges. In addition, additional test were conducted to verify the strength equations of the connection between steel coupling beam and reinforced concrete shear wall. The results of the proposed equations in this study are in good agreement with both our test results and other test data from the literature.

키워드

참고문헌

  1. Pauley, T. and Binney, J. R., Diagonally Reinforced Coupling Beams of Shear Walls, Shear in Reinforced Concrete: Publication No.42, ACI, Detroit, USA, 1974, pp.579-598
  2. Harries, KA., 'Ductility and defonnability of coupling beams in reinforced concrete shear walls', Earthquake Spectra, Vol.17, No.3, 2001, pp.457-78 https://doi.org/10.1193/1.1586184
  3. Roeder, C. W. and Popov, E. P., 'Eccentrically Braced Steel Frames for Earthquakes', J. Struct. Div., ASCE, Vol.104, No.3, 1978, pp.391-411
  4. Gong, B. and Shahrooz B. M., 'Concrete-Steel Composite Coupling Beams', Journal of the Structural Division, ASCE, Vol.127, No.6, 2001, pp.625-631 https://doi.org/10.1061/(ASCE)0733-9445(2001)127:6(625)
  5. PCI Manual on Design of Connections for Precast Prestressed Concrete, Prestressed Concrete Institute, Chicago, 1973, pp.25-38
  6. PCI Design Handbook - Precast and Prestressed Concrete, Prestressed Concrete Institute, Chicago, 1978, 370pp
  7. Kriz, L. B. and Raths, C. H., 'Connection in Precast Concrete Structures-Shear strength of Column Heads', Journal, Prestressed Concrete Institute, Vol.8, No.6, Dec.1963, pp.45-75
  8. Williams, A., The Bearing Capacity of Concrete Loaded Over a limited Area, Technical Report No. 526, Cement and Concrete Association, London, Aug. 1979, pp.70-80
  9. Mattock, A. H. and Gaafar, G. H., 'Strength of Embedded Steel Sections as Brackets', ACI Journal, Vol.79, No.9, Mar.-Apr., 1982, pp.83-93
  10. ACI Committee 318, Building Code Requirements for Structural Concrete and Commentary, American Concrete Institute, Detroit, USA, 2005, pp.105-110
  11. Kent, D. C. and Park, R., 'Flexural Members with Confined Concrete', Journal of the Structural Division, ASCE, Vol.97, ST7, Jul. 1971, pp.1969-1990
  12. Gong B. and Shahrooz B. M., Gillum A. J., Cyclic Response of Composite Coupling Beams, ACI Committee 335 Special Publication, 199
  13. Gong B. and Shahrooz B. M., 'Concrete-Steel Composite Coupling Beams', Journal of Structural Engineering Vol.127, No.6, Jun., 2001, pp.625-631 https://doi.org/10.1061/(ASCE)0733-9445(2001)127:6(625)
  14. Shahrooz B. M., Remmetter M. A., and Qin F., Seismic Response of Composite Coupled Walls, Composite Construction in Steel and Concrete II, ASCE, New York, N. Y., 1992, pp.428-441
  15. Hawkins, N. M., 'The Shear strength of Concrete for Strip Loading', Magazine of Concrete Research (London), Vol.22, No.71, Jun. 1970, Aug. 1979, pp.87-97 https://doi.org/10.1680/macr.1970.22.71.87
  16. Yun H. D, Park W. S, Han B. C, Hwang S. K., and Yang I. L., 'Bearing Strength of Steel Coupling Beam-Wall Connections depend upon Joint Details', Journal of the Architectural Institute of Korea, Vol.20, No.12, 2004, pp.61-8