• Title/Summary/Keyword: Welding Electrode

Search Result 243, Processing Time 0.031 seconds

Tensile Testing of Groove Welded Joints Joining Thick-HSA800 Plates (HSA800 후판재의 맞댐용접부 인장강도 실험)

  • Lee, Cheol Ho;Kim, Dae Kyung;Han, Kyu Hong;Park, Chang Hee;Kim, Jin Ho;Lee, Seung Eun;Kim, Do Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.4
    • /
    • pp.431-440
    • /
    • 2013
  • In this study, a standard tensile welded-joint test was conducted to select a welding electrode suitable for recently developed HSA800 steel. Two welding electrodes were available at the time of this study; one was GMAW-based and the other FCAW-based. The tensile test specimens were fabricated by joining 60mm-thick HSA800 plates according to the AWS-prequalified groove welded joint details. Specimens which violate the standard root opening distance (ROD) were also included to see if poor construction tolerance could be accommodated. During fabrication, serious concerns about the welding efficiency of the GMAW-based product were raised by a certified welder. Both welding electrodes showed satisfactory and similar performance from welded joint strength perspective. But groove welded joints made by using the FCAW-based rod consistently showed more ductile and stable behavior. The AISC provisions for PJP joint strength were shown to be very conservative under direct tensile loading. Violating the AWS prequalified ROD by 100% apparently passed the strength criteria, but unusual crater-like fracture surface was observed.

Characteristics Evaluation on Welding Metal Zones Welded with Inconel 625 Filler Metal to Cast Steel for Piston Crown Material

  • Jeong, Jae-Hyun;Moon, Kyung-Man;Lee, Sung-Yul;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.542-547
    • /
    • 2015
  • Since the oil price has been significantly jumped for several years, a heavy oil of low quality has been mainly used in the diesel engine of the merchant ship. Thus, a combustion chamber of the engine has been often exposed to severely corrosive environment more and more because temperature of the exhaust gas of the combustion chamber has been getting higher and higher with increasing of using the heavy oil of low quality. As a result, wear and corrosion of the engine parts such as exhaust valve, piston crown and cylinder head surrounded with combustion chamber are more serious compared to the other parts of the engine. Therefore, an optimum repair welding for these engine parts is very important to prolong their lifetime in a economical point of view. In this study, Inconel 625 filler metal were welded with GTAW method in the cast steel which would be generally used with piston crown material. And the corrosion properties of weld metal, heat affected and base metal zones were investigated using electrochemical methods such as measurement of corrosion potential, anodic polarization curves, cyclic voltammogram and impedance etc. in 35% $H_2SO_4$ solution. The weld metal and base metal zones exhibited the highest and lowest values of hardness respectively. Furthermore, the corrosion current density of the weld metal zone revealed the lowest value, having the highest value of hardness. The corrosive products with red color and local corrosion like as a pitting corrosion were considerably observed at the base metal zone, while these morphologies were not wholly observed in the weld metal zone. In particular, the polarization characteristics such as impedance, polarization curve and cyclic voltammogran associated with corrosion resistance property were well in good agreement with each other. Consequently, it is suggested that the mechanical and corrosion characteristics of the piston crown can be predominantly improved by repair welding method using the Inconel 625 electrode.

Optimization of Resistance Spot Weld Condition for Single Lap Joint of Hot Stamped 22MnB5 by Taking Heating Temperature and Heating Time into Consideration (핫스템핑 공정에서 가열온도 및 유지시간을 고려한 22MnB5의 단일겹치기 저항 점용접 조건 최적화)

  • Choi, Hong-Seok;Kim, Byung-Min;Park, Geun-Hwan;Lim, Woo-Seung;Lee, Sun-Bong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1367-1375
    • /
    • 2010
  • In this study, optimization of the process parameters of the resistance spot welding of a sheet of aluminum-coated boron alloyed steel, 22MnB5, used in hot stamping has been performed by a Taguchi method to increase the strength of the weld joint. The process parameters selected were current, electrode force, and weld time. The heating temperature and heating time of 22MnB5 are considered to be noise factors. It was known that the variation in the thickness of the intermetallic compound layer between the aluminum-coated layer and the substrate, which influences on the formation of nugget, was generated due to the difference of diffusion reaction according to heating conditions. From the results of spot weld experiment, the optimum weld condition was determined to be when the current, electrode force, and weld time were 8kA, 4kN, and 18 cycles, respectively. The result of a test performed to verify the optimized weld condition showed that the tensile strength of the weld joint was over 32kN, which is considerably higher than the required strength, i.e., 23kN.

저항용접 시뮬레이션을 이용한 가공전극 적용 용접 특성 평가

  • Lee, Sang-Min;Choi, Du-Youl;Park, Yeong-Do
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.97-97
    • /
    • 2010
  • 최근 자동차에서 경량화의 방안으로써 높은 강성을 요구하는 고장력강 사용이 증대 되고 있다. 그러나 고장력강은 저항 점용접 시 일반 강에 비해 높은 전류를 요구하며 계면파단 및 expulsion 발생이 용이하기 때문에 가용 전류 구간이 좁은 특성을 가진다. 많은 연구자들이 hold time, tempering 등의 process를 이용하여 고장력강의 저항 점용접성을 개선하고자 하였으나 생산 공정라인에 적용하기는 어려운 실정이다. 본 연구에서는 용접 공정 변수의 변화에 따른 용접성과 전극 형상 변화을 통한 고장력강 점 용접성 향상에 대한 연구를 실시 하였다. 고장력강의 점 용접성 비교하기 위해 표준 전극(S1)과 인위적으로 가공한 전극(M1)을 사용하였으며, 실험에 사용된 판재는 두께 1.4mm의 DP590이며, 그 결과 표준전극(S1) 보다 가공 전극(M1)의 가용 전류 구간이 0.5kA 정도 넓은 것으로 확인 되었다. 두 전극을 사용한 점용접 시험편들의 인장전단강도를 비교 해보면 표준전극(S1)을 적용한 점용접 시 인장전단강도는 KS B 0850 기준에 만족하나 계면 파단이 발생 하였다. 가공 전극(M1)을 적용한 점용접 시 인장전단강도는 규격 기준에 만족하나 버튼 파단이 발생 하였다. 두 전극을 적용한 점용접부 형상 및 용접부 온도 분포에대해 저항점용접 시뮬레이션 프로그램(SORPAS)을 이용하여 실험 결과 값과 비교 분석하였고 파단모드의 변화에 대한 원인 분석을 도출 하였다.

  • PDF

Study on the Interfacial Reactions between Gallium and Cu/Au Multi-layer Metallization (갈륨과 Cu/Au 금속층과의 계면반응 연구)

  • Bae, Junhyuk;Sohn, Yoonchul
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.2
    • /
    • pp.73-79
    • /
    • 2022
  • In this study, a reaction study between Ga, which has recently been spotlighted as a low-temperature bonding material, and Cu, a representative electrode material, was conducted to investigate information necessary for low-temperature soldering applications. Interfacial reaction and intermetallic compound (IMC) growth were observed and analyzed by reacting Ga and Cu/Au substrates in the temperature range of 80-200℃. The main IMC growing at the reaction interface was CuGa2 phase, and AuGa2 IMC with small particle sizes was formed on the upper part and Cu9Ga4 IMC with a thin band shape on the lower part of the CuGa2 layer. CuGa2 particles showed a scallop shape, and the particle size increased without significant shape change as the reaction time increased, similar to the case of Cu6Sn5 growth. As a result of analyzing the CuGa2 growth mechanism, the time exponent was calculated to be ~3.0 in the temperature range of 120-200℃, and the activation energy was measured to be 17.7 kJ/mol.

The study on corrosion fatigue and cathodic protection of the steel plates used for the shipbuilding (조선용강재의 부식피로와 전기방식에 관한 연구)

  • 전대희;김원녕;이의호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.126-142
    • /
    • 1985
  • The plane bending corrosiion fatigue test for the welded metal parats was performed in the air and in the natural sea water with and without applying cathodic protection. The specimens tested were the weld of SM41 steel plates, SM58 steel plates and of SM41 to SM58, which were all prepared by submerged arc welding. The main results obtained from the experiment are summarized as follows: (1) In case with SM41 and SM58 steel plates, lower value of impact strength, higher value of hardness and more noble electrode potential were observed in the welded metal part than in the HAZ and base metal. Also the lowest hardness zone in the HAZ was observed with SM58 which was not found with SM41. In case with weld specimen of SM41 to SM58, the impact strength and the electrode potential of the welded metal part showed again the lowest and most noble value but the hardness value was located between those of SM41 and SM58 base metal. (2) In the fatigue test, the specimens tested in the air and under the cathodic protection were both cracked in a purely mechanical mode, but the specimens tested without cathodic protection were cracked by the combination of mechanical fracture and electro-chemical corrosion. (3) The corrosion fatigue limit of the welded metal parts of the specimen was increased by the cathodic protection. As the protection potential was varied down to -800 mV vs. SCE the fatigue limit was increased to the value tested in the air, and the maximum fatigue limit appeared at the -1, 000 - -1, 200 mV vs. SCE. However, as the protection potential was further decreased below -1, 200 mV vs.SCE, the fatigue limit of weld of SM58 and of SM41-SM58 joining was decreased but the limit was almost constant in the case of weld of SM41. (4) It is suggested that when designing steel ship the corrosion fatigue limit of welded metal parts should be stressed as a designing strength of the structure of steel ship in addition to the conventional basis considering simply tensile strength of steel and safety factor.

  • PDF

Study of Seal-off Triggered Vacuum Switch(TVS) for High Voltage and High Current (고전압 대전류용, Seal-off TVS(Triggered Vacuum Switch) 연구)

  • Park, S.S.;Han, Y.J.;Kim, S.H.;Kwon, Y.K.;Kim, S.H.;Park, Y.J.;Hong, M.S.;Nam, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1823-1826
    • /
    • 2002
  • The purpose of this experiment was to develope Triggered Vacuum Switch (TVS) for the high voltage and high current. The TVS has an array of rods of alternate polarity in which a fixed gap spacing is maintained between the rods. The cross section of each rod has trapezoidal shape. It consists of electrode, ceramic chamber, getter and trigger. Currently, triggered vacuum switch (TVS) with seal-off has been designed and fabricated at PAL. An experimentation and trigger devices for TVS were designed for testing characteristics of electricity. For making the prototype of TVS, it is developed of fabrication process and fined of electrode material. The fabrication of the TVS is a lot of process which have manufacturing of part, chemical clean, ceramic brazing and metal welding. The fabricated TVS is tested of leak for vacuum, hold-off voltage and conditioning of trigger system. The TVS has pinch-off after it is removed of gas in the TVS and activated of getter in degassing furnace. The prototype TVS tested about 20 kV, 75 kA, 83 ${\mu}s$ with 100 kJ capacitor bank and inductance 5 ${\mu}H$. This paper describes the results of tests and the characteristics of the switch.

  • PDF

An Experimental Study on the Turning Property of Welded Material (용접부의 선삭특성에 관한 실험적 연구)

  • Jang, Bok-Deuk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.3 no.3
    • /
    • pp.13-21
    • /
    • 1986
  • Turning property of metal is affected by the cutting condition, tool geome- try and cutting material. But the turning property of welded material is not welknown. Welded structures usually contain nonhomogeneity, defects and resi- dual stresses due to differential contraction between welded metal and base metal. In this paper, authors conducted the experimental test on the turning property, by changing turning condition and welding electrodes of the welded specimens. The results obtained in these experimental tests are as follows; (1) Within the limit of this experimental test, the cutting force of the weld zone is bigger than that of base metal, and this phenomena is caused by the different mechanical property of the weld zone. The range of the variation of cutting force in the weld zone is caused by the nonhomogeneity of the weld zone, respectively. (2) The surface roughness follows the general characteristic of the effect of cutting condition on the surface roughness and the surface roughness of the weld zone shows coarse surface comparing with that of the base metal. (3) The specimen welded by the electrode E4301, shows worse cutting property than that of E4361 and E4313.

  • PDF

Consideration of Methods Evaluating the Growing Process of Stress Corrosion Cracking of the Sensitized 18-8 Austenitic Stainless Steel in High Temperature Water Based on Electric Circuit Theory: The Effects of Stress Factors

  • Tsukaue, Yasoji
    • Corrosion Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.103-111
    • /
    • 2007
  • The effect of stress factors on the growing process of stress corrosion cracking (SCC) of the sensitized 18-8 stainless steel in high temperature water was investigated using equations of crack growth rate derived from applying electric circuits to SCC corrosion paths. Three kinds of cross sections have to be considered when electric circuit is constructed using total current. The first is ion flow passage area, $S_{sol}$, of solution in crack, the second is total dissolving surface area, $S_{dis}$, of metal on electrode of crack tip and the third is dissolving cross section, $S_{met}$, of metal on grain boundary or in base metal or in welding metal. Stress may affect each area. $S_{sol}$ may depend on applied stress, $\sigma_{\infty}$, related with crack depth. $S_{dis}$ is expressed using a factor of $\varepsilon(K)$ and may depend on stress intensity factor, K only. SCC crack growth rate is ordinarily estimated using a variable of K only as stress factor. However it may be expected that SCC crack growth rate depends on both applied stress $\sigma_{\infty}$ and K or both crack depth and K from this consideration.$\varepsilon(K)$ is expressed as ${\varepsilon}(K)=h_2{\cdot}K^2+h_3{\cdot}K^3$ when $h_{2}$ and $h_{3}$ are coefficients. Also, relationships between SCC crack growth rate, da/dt and K were simulated and compared with the literature data of JBWR-VIP-04, NRC NUREG-0313 Rev.2 and SKIFS Draft. It was pointed out in CT test that the difference of distance between a point of application of force and the end of starter notch (starting point of fatigue crack) may be important to estimate SCC crack growth rate. An anode dissolution current density was quantitatively evaluated using a derived equation.

Oxidation Behavior of Ti Added Alumina Dispersion Strengthening Copper Alloy (티타늄이 첨가된 알루미나 분산강화 동합금의 산화물 형성 거동)

  • Joh, Hongrae;Han, Seung Zeon;Ahn, Jee Hyuk;Lee, Jehyun;Son, Young Guk;Kim, Kwang Ho
    • Korean Journal of Materials Research
    • /
    • v.25 no.4
    • /
    • pp.202-208
    • /
    • 2015
  • Alumina dispersion strengthening copper(ADSC) alloy has great potential for use in many industrial applications such as contact supports, frictional break parts, electrode materials for lead wires, and spot welding with relatively high strength and good conductivity. In this study, we investigated the oxidation behavior of ADSC alloys. These alloys were fabricated in forms of plate and round type samples by surface oxidation reaction using Cu-0.8Al, Cu-0.4Al-0.4Ti, and Cu-0.6Al-0.4Ti(wt%) alloys. The alloys were oxidized at $980^{\circ}C$ for 1 h, 2 h, and 4 h in ambient atmosphere. The microstructure was observed with an optical microscope(OM) and a scanning electron microscope(SEM) equipped with energy-dispersive X-ray spectroscopy(EDS). Characterization of alumina was carried out using a 200 kV field-emission transmission electron microscope(TEM). As a result, various oxides including Ti were formed in the oxidation layer, in addition to ${\gamma}$-alumina. The thickness of the oxidation layer increased with Ti addition to the Cu-Al alloy and with the oxidation time. The corrected diffusion equation for the plate and round type samples showed different oxidation layer thickness under the same conditions. Diffusion length of the round type specimen had a value higher than that of its plate counterpart because the oxygen concentration per unit area of the round type specimen was higher than that of the plate type specimen at the same diffusion depth.