• Title/Summary/Keyword: Wee1

Search Result 727, Processing Time 0.036 seconds

Temperature-dependent developmental models and fertility life table of the potato aphid Macrosiphum euphorbiae Thomas on eggplant (감자수염진딧물(Macrosiphum euphorbiae Thomas)의 온도발육모형과 출산생명표)

  • Jeon, Sung-Wook;Kim, Kang-Hyeok;Lee, Sang Guei;Lee, Yong Hwan;Park, Se Keun;Kang, Wee Soo;Park, Bueyong;Kim, Kwang-Ho
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.4
    • /
    • pp.568-578
    • /
    • 2019
  • The nymphal development of the potato aphid, Macrosiphum euphorbiae (Thomas), was studied at seven constant temperatures (12.5, 15.0, 17.5, 20.0, 22.5, 25.0, and 27.5±1℃), 65±5% relative humidity (RH), and 16:8 h light/dark photoperiods. The developmental investigation of M. euphorbiae was separated into two steps, the 1st through 2nd and the 3rd through 4th stages. The mortality was under 10% at six temperatures. However, it was 53.0% at 27.5℃. The developmental time of the entire nymph stage was 15.5 days at 15.0℃, 6.7 days at 25.0℃, and 9.7 days at 27.5℃. In the immature stage, the lower threshold temperature of the larvae was 2.6℃ and the thermal constant was 144.5 DD. In our analysis of the temperature-development experiment, the Logan-6 model equation was most appropriate for the non-linear regression models (r2=0.99). When the distribution completion model of each development stage of M. euphorbiae larvae was applied to the 2-parameter and 3-parameter Weibull functions, each of the model's goodness of fit was very similar (r2=0.92 and 0.93, respectively). The adult longevity decreased as the temperature increased but the total fecundity of the females at each temperature was highest at 20℃. The life table parameters were calculated using the whole lifespan periods of M. euphorbiae at the above six temperatures. The net reproduction rate (R0) was highest at 20.0℃(63.2). The intrinsic rate of increase (rm) was highest at 25℃(1.393). The finite rate of doubling time (Dt) was the shortest at 25.0℃(2.091). The finite rate of increase (λ) was also the highest at 25.0℃(1.393). The mean generation time(T) was the shortest at 25.0℃(9.929).

Comparison of an Automated Most-Probable-Number Technique TEMPO®TVC with Traditional Plating Methods PetrifilmTM for Estimating Populations of Total Aerobic Bacteria with Livestock Products (축산물가공품에서 건조필름법과 TEMPO®TVC 검사법의 총세균수 비교분석)

  • Kim, Young-Jo;Wee, Sung-Hwan;Yoon, Ha-Chung;Heo, Eun-Jeong;Park, Hyun-Jeong;Kim, Ji-Ho;Moon, Jin-San
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.1
    • /
    • pp.103-107
    • /
    • 2012
  • We compared between an automated most-probable-number technique $TEMPO^{(R)}$TVC and traditional plating methods $Petrifilm^{TM}$ for estimating populations of total aerobic bacteria in various livestock products. 257 samples randomly selected in local retail stores and 87 samples inoculated with $E.$ $coli$ ATCC 25922, $Staphylococcus$ $aureus$ ATCC 12868 were tested in this study. The degree of agreement was estimated according to the CCFRA (Campden and Chorleywood Food Research Association Group) Guideline 29 and the agreement indicates the difference of two kinds methods is lower than 1 log base 10($log_{10}$). The samples of hams, jerky products, ground meat products, milks, ice creams, infant formulas, and egg heat formed products were showed above 95% in the agreement of methods. In contrast, proportion of agreement on meat extract products, cheeses and sausages were 93.1%, 92.1%, 89.1%, respectively. One press ham and five sausages containing spice and seasoning, two pork cutlets containing spice and bread crumbs, two meat extract product and two natural cheeses and one processing cheese with a high fat content, and one ice cream containing chocolate of all samples showed the discrepancy. Our result suggest that $TEMPO^{(R)}$TVC system is efficient to analyses total aerobic bacteria to compare manual method in time-consuming and laborious process except livestock products having limit of detection.

A Study on Electron Dose Distribution of Cones for Intraoperative Radiation Therapy (수술중 전자선치료에 있어서 선량분포에 관한 연구)

  • Kang, Wee-Saing;Ha, Sung-Whan;Yun, Hyong-Geun
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.1-12
    • /
    • 1992
  • For intraoperative radiation therapy using electron beams, a cone system to deliver a large dose to the tumor during surgical operation and to save the surrounding normal tissue should be developed and dosimetry for the cone system is necessary to find proper X-ray collimator setting as well as to get useful data for clinical use. We developed a docking type of a cone system consisting of two parts made of aluminum: holder and cone. The cones which range from 4cm to 9cm with 1cm step at 100cm SSD of photon beam are 28cm long circular tubular cylinders. The system has two 26cm long holders: one for the cones larger than or equal to 7cm diamter and another for the smaller ones than 7cm. On the side of the holder is an aperture for insertion of a lamp and mirror to observe treatment field. Depth dose curve. dose profile and output factor at dept of dose maximum. and dose distribution in water for each cone size were measured with a p-type silicone detector controlled by a linear scanner for several extra opening of X-ray collimators. For a combination of electron energy and cone size, the opening of the X-ray collimator was caused to the surface dose, depths of dose maximum and 80%, dose profile and output factor. The variation of the output factor was the most remarkable. The output factors of 9MeV electron, as an example, range from 0.637 to 1.549. The opening of X-ray collimators would cause the quantity of scattered electrons coming to the IORT cone system. which in turn would change the dose distribution as well as the output factor. Dosimetry for an IORT cone system is inevitable to minimize uncertainty in the clinical use.

  • PDF

Carbon Fiber as Material for Radiation Fixation on Device : A comparative study with acrylic (고정기구 재질로써 탄소 섬유와 아크릴의 방사선량 감쇄 영향 비교)

  • Chie, Eui-Kyu;Park, Jang-Pil;Huh, Soon-Nyung;Hong, Se-Mie;Park, Suk-Won;Kim, In-Ah;Wu, Hong-Gyun;Kim, Jae-Sung;Kang, Wee-Saing;Kim, Il-Han;Ha, Sung-Whan;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Radiation absorption parameters of carbon fiber panel were measured in comparison to acrylic panel. $30{\times}30cm$ sized 2mm thick carbon fiber panel and identical sized 6mm thick acrylic panel were placed in tray holder position and 0cm, 5cm, 10cm from surface of phantom. Radiation field size was $10{\times}10cm$. 50MU of 4MV photon was irradiated to the phantom with dose rate of 300MU/min. Source-to-phantom distance was 120cm. Radiation dose was measured with 0.6cc Farmer-type ionization chamber with 1cm build-up. Measurement was repeated thrice and normalization was done to the dose of the open field. Radiation transmission rate of carbon fiber panel is approximately 1% lower than acrylic panel of equivalent thickness. However, considering the strength of the material, transmission rate is higher for carbon fiber panel. Although carbon fiber panel increases the radiation dose when attached to the surface for about 2%, it normalizes the radiation dose to 97-99% of irradiated dose which could have been lowered to as much as 5-7.5% with acrylic panel. As carbon fiber panel is stronger than acrylic panel, radiation fixation device could be made thinner and thus lighter and furthermore, with increased radiation transmission. This in turn makes carbon fiber more ideal material for radiation fixation device over conventionally used acrylic.

Characteristics of Springtime Temperature Within Mt. Youngmun Valley (용문산 산악지역의 봄철 기온특성)

  • Chun, Ji Min;Kim, Kyu Rang;Lee, Seon-Yong;Kang, Wee Soo;Choi, Jong Mun;Hong, Soon Sung;Park, Jong-Seon;Park, Eun-U;Kim, Yong Sam;Choi, Young-Jean;Jung, Hyun-Sook
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.16 no.1
    • /
    • pp.39-50
    • /
    • 2014
  • This paper reviews the results of recent observations in the Yeonsuri valley of Mt. Youngmun during springtime (March to May) in 2012. Automated weather stations were installed at twelve sites in the valley to measure temperature and 2, 3 dimensional wind. We examined temporal and spatial characteristics of temperatures and wind data. The Yeonsuri valley springtime average temperature lapse rate between the top and bottom of the entire period is $-0.44^{\circ}C/100$ m. It can be changed by the synoptic weather conditions, the lapse rates is greatest in order of clear days ($-0.48^{\circ}C/100$ m), rainy ($-0.41^{\circ}C/100$ m) and cloudy days ($-0.40^{\circ}C/100$ m). In the night, the temperature inversion layer (thermal belt) and the cold pool are formed within the valley. In addition, we measured temperature and wind distribution from the bottom to 3.5 m, the cold layers existed up to 1.5 m, which were affected by ground mixed layer. The results will provide useful guidance on agricultural practices as well as model simulations.

Phoria Changes Caused by Lens Adaptation after Wearing of Horizontal Prism Lens and Spherical Lens (수평 프리즘렌즈와 구면렌즈 착용 후 렌즈적응에 의한 사위도의 변화)

  • Lee, Min Jae;Kim, Sang-Yeob;Wee, Sung-Hyun;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.53-59
    • /
    • 2016
  • Purpose: To investigate an individual phoria compensating effect by measuring the lens adaptation after wearing horizontal prism or spherical lenses at near. Methods: 103 subjects (63 males and 40 females) aged $22.43{\pm}2.07years$ participated for this study. Refractive errors of subjects were fully corrected, and subjects were classified into three groups; esophoria, orthophoria and exophoria. The adaptation test of prism and spherical lenses was performed immediately, 15 minutes and 30 minutes after wearing lenses with $OU\;2\;{\Delta}\;BO$ and S+1.00 D for an esophoria group and $OU\;2\;{\Delta}\;BI$ and S-1.00 D for orthophoria and exophoria groups, respectively. Each measured phoria was compared to phoria measured with fully corrected condition, and the phoria changing effects about both lenses was analyzed. Results: The mean of phoria by prism lenses significantly decreased for every group. The mean of phoria by spherical lenses also significantly decreased in orthophoria and exophoria groups. The esophoria group showed a decreasing tendency but has no significance. The decreased phoria value by prism lens was classified into three steps; 90~100%, 0~10% and 50% or more. According to results of individual distribution ratio, it was 5, 64 and 24 subjects at 30 minutes after wearing lenses, respectively. The decreased phoria value by spherical lens was classified into three steps; 90~100%, 0~10% and 50% or more. According to results of individual distribution ratio, it was 37, 53 and 41 subjects at 30 minutes after wearing lenses, respectively. The subjects having no phoria changed by both prism and spherical lenses were 37.9%. Conclusions: When prescribing to compensate the near horizontal phoria using prism or spherical lens, the pretest for lens adaptation should be taken before prescription.

Clinical Effects of SJ-002 on URI - Upper Respiratory Tract Infection - (상기도감염증에 대한 SJ-002액의 임상적 고찰)

  • Chung, Byung-Chun;Kim, Kwang-Won;Woo, Un-Joh;Lee, Young-Sunk;Kim, Seung-Woan;Choi, Young-Hwan;Kim, Yeon-Jae;Kim, Sung-Rok;Kim, Soo-Dong
    • The Korean Journal of Pharmacology
    • /
    • v.27 no.2
    • /
    • pp.211-214
    • /
    • 1991
  • SJ-200 is an oral liquid preparation of acetaminophen, ibuprofen, Dl-methyleph edrine HCl, caffeine, chlorpheniramine maleate, guaifenesin and dextromethorphan HBr, which is indicated when there is a need to improve various cold symptoms such as headache, sore throat, fever, or cough etc. Thirty patients was enroled for this study fro June to July, 1991. They were given one bottle (30 ml) of SJ-200 t.i.d dy P.O for an average of one to seven days. 1) Twenty-eight patients (84.8%) were relieved from the symptoms of upper respiratory tract infection. 2) Side effects with this preparation occured in 8 patients924.2%) but in four patients, they were mild, which wee transienty by the discontinuation f the medication.

  • PDF

Etiologies of Bacterial Pneumonia with Implications for Therapy (세균성 폐렴의 원인균과 그 치료)

  • Woo, Jun-Hee;Lee, Jae-Seok;Kwon, Kwang-Ho;Kim, Kyung-Ho;Choi, Chang-Hyun;Park, Choon-Sik;Lee, Wee-Gyo;Choi, Tae-Youn
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.1
    • /
    • pp.67-75
    • /
    • 1995
  • Background: Although we gain new knowledge, the problem of pneumonia will not be eliminated. We should understand who is at risk, why these people develop this problem, what causes the pneumonia, and how to manage and prevent respiratory infection. To clarify the alterations of the etiologies of bacterial pneumonia we analysed the recent causative organisms and evaluated the therapeutic implications. Methods: A retrospective four-year study of bacterial pneumonia was conducted in Soon Chun Hyang University Hospital. 190 episodes of bacterial pneumonia was investigated. Results: 1) The causative organisms were isolated in 173 cases on the sputum culture: 154 cases (89%) were gram negative bacilli and 19 cases(11%) were gram positive cocci. The major organisms were Pseudomonas species 49 cases(28%), Klebsiella pneumoniae 29 cases(17%), Enterobacter species 25 cases(14%), and Acinetobacter species 20 cases(12%) in decreasing order. Pseudomonas species(13 cases, 34%) were frequently found in nosocomial pneumonia. 2) The causative organisms were isolated in 16 cases on the blood culture: 7 cases(43%) were gram negative bacilli and 9 cases(57%) were gram positive cocci. The major organisms were Staphylococcus aureus(6 cases, 38%), Pseudomonas species(3 cases, 19%) in decreasing order. 3) In the susceptibility test of causative organisms to antimicrobial drugs, Pseudomonas was susceptible to amikacin, ciprofloxacin, aztreonam, ceftazidime(more than 50%) and resistant to piperacillin, gentamicin, carbenicillin(more than 60%). Klebsiella was susceptible to chloramphenicol, gentamicin, cefotetan(more than 70%) and resistant to carbenicillin, ampicillin(more than 70%). Staphylococcus was susceptible to methicillin(64%), and Streptococcus pneumoniae was susceptible to oxacillin(94%). 4) The response rate after antibiotics therapy was 81% and the mortality rate was 19%. Conclusion: As considering the changes of causative organisms and antibiotic resistance, it behooves us to exercise caution in dispending antibiotics in order to maximize their continued efficacy and to do appropiate antibiotics therapy based on cultures and susceptibility test.

  • PDF

A Feasibility Study on Thermal Energy Resource in Deep Ocean Water (해양심층수 에너지자원 이용 타당성 분석 연구)

  • Kim, Jeong-Hyop;Kim, Gwang-Tae;Park, Se-Hun;Oh, Wee-Yeong;Kim, Hyeon-Ju
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.1
    • /
    • pp.9-18
    • /
    • 2012
  • Annual power consumption of our country is positioned in the upper percentile in the world, and because the proportion of fossil power generation is high, which ranks the 10th $CO_2$ emission country. In this regard, government has established and is implementing the National Energy Basic Plan to realize to get out of fossilization in energy supply while focusing on securing the technology for renewable energy as well as its commercialization in order to reduce greenhouse gas. Resource recovery technology for deep seawater thermal energy which is one of renewable energies is newly getting attention domestically as well as in overseas for securing resources and environmental improvement as a core technology for multilateral use of marine resources for low carbon and green growth. Economic feasibility analysis was conducted for the research and development as follows on the use of ocean thermal energy conversion and seawater air conditioning. First, in the case of power generation using deep seawater and warm discharge water from ocean thermal energy conversion plant of 1MW level, it is judged that the economic feasibility is insufficient but the feasibility will be significantly improved if we consider not only power generation but also drinking water and certified emission reduction by developing the power plant to the size for commercialization. Second, the economic feasibility for the use of deep seawater as air conditioning for the power plant of 1,000RT level turned out to be very good. Especially, when we consider certified emission reduction, it will be possible to secure sufficient economic feasibility. When we use it in connection with ocean thermal energy conversion, water conversion and agricultural and fishery use, it is judged that economic ripple effect will be significant and therefore it will be necessary to conduct research and development for early commercialization, distribution and diffusion of deep seawater energy.

Preparation and Animal Imaging of $^{153}Sm$-EDTMP as a Bone Seeking Radiopharmaceutical (골친화성 방사성의약품 $^{153}Sm$-EDTMP의 합성과 동물영상)

  • Choi, Tae-Hyun;Kim, Se-Jung;Shin, Byung-Chul;Woo, Kwang-Sun;Chung, Wee-Sup;Choi, Chang-Woon;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.44-48
    • /
    • 2005
  • Purpose: Ethylenediamine-tetramethylenephosphonic acid (EDTMP) has widely used chelator for the labeling of bone seeking radiopharmaceuticals complexed with radiometals. $^{153}Sm$ can be produced by the HANARO reactor at the Korea Atomic Energy Research Institute, Taejon, Korea. $^{153}Sm$ has favourable radiation characteristics $T1/2=46.7\;h,\;{\beta}_{max}=0.81\;MeV\;(20%),\;0.71\;MeV\;(49%),\;0.64\;MeV\;(30%)\;and\;{\gamma}=103\;keV\;(30%)$ emission which is suitable for imaging purposes during therapy. We investigated the labeling condition of $^{153}Sm$-EDTMP and imaging of $^{153}Sm$-EDTMP in normal rats. Materials and methods: EDTMP 20 mg was solved in 0.1 mL 2 M NaOH. $^{153}SmCl^3$ was added to EDTMP solution and pH of the reaction mixtures was adjusted to 3 and 12, respectively. Radiochemical purity was determined with paper chromatography. After 30 min. reaction, reaction mixtures were neutralized to pH 7.4, and the stability was estimated upto 120 hrs. Imaging studies of each reaction were perfomed in normal rats (37 MBq/0.1 mL). Results: The labeling yield of $^{153}Sm$-EDTMP was 99%. The stability of pH 8 reaction at 60, 96 and 120 hr was 99%, 95%, 89% and that of pH 12 at 36, 60, 96 and 120 hr was 99%, 95%, 88%, 66%, respectively. The $^{153}Sm$-EDTMP showed constantly higher bone uptake from 2 to 48 hr after injection. Conclusion: $^{153}Sm$-EDTMP, labeled at pH 8 reaction condition, has been stably maintained. Image of $^{153}Sm$-EDTMP at 2, 24, 48 hr after injection, demonstrate that $^{153}Sm$-EDTMP is a good bone seeking radiopharmaceuticals.