마이크로터빈이 포함된 빌딩마이크로그리드시스템의 병원건물의 에너지성능평가 (Energy Performance Evaluation of Building Micro-grid System Including Micro-turbine in Hospital Buildings)

  • 김병수;홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.279-283
    • /
    • 2009
  • Distributed generation(DG) of combined cooling, heat. and power(CCHP)has been gaining momentum in recent year as efficient, secure alternative for meeting increasing energy demands. This paper presents the energy performance of microturbine CCHP system equipped with an absorption chiller by modelling it in hospital building. The orders of study were as following. 1)The list and schedule of energy consumption equipment in hospital were examined such as heating and cooling machine, light etc. 2) Annual report of energy usage and monitoring data were examined as heating, cooling, DHW, lighting, etc. 3) The weather data in 2007 was used for simulation and was arranged by meteorological office data in Daejeon. 4) Reference simulation model was built by comparison of real energy consumption and simulation result by TRNSYS and ESP-r. The energy consumption pattern of building were analyzed by simulation model and energy reduction rate were calculated over the cogeneration. As a result of this study, power generation efficiency of turbine was about 30% after installing micro gas turbine and lighting energy as well as total electricity consumption can be reduced by 40%. If electricity energy and waste heat in turbine are used, 56% of heating energy and 67% of cooling energy can be reduced respectively, and total system efficiency can be increased up to 70%.

  • PDF

한국에서 발생한 청천난류 사례들에 대한 수치연구 (A Numerical Study on Clear-Air Turbulence Events Occurred over South Korea)

  • 민재식;김정훈;전혜영
    • 대기
    • /
    • 제22권3호
    • /
    • pp.321-330
    • /
    • 2012
  • Generation mechanisms of the three moderate-or-greater (MOG)-level clear-air turbulence (CAT) encounters over South Korea are investigated using the Weather Research and Forecasting (WRF) model. The cases are selected among the MOG-level CAT events occurred in Korea during 2002-2008 that are categorized into three different generation mechanisms (upper-level front and jet stream, anticyclonic flow, and mountain waves) in the previous study by Min et al. For the case at 0127 UTC 18 Jun 2003, strong vertical wind shear (0.025 $s^{-1}$) generates shearing instabilities below the enhanced upper-level jet core of the maximum wind speed exceeding 50 m $s^{-1}$, and it induces turbulence near the observed CAT event over mid Korea. For the case at 2330 UTC 22 Nov 2006, areas of the inertia instability represented by the negative absolute vorticity are formed in the anticyclonically sheared side of the jet stream, and turbulence is activated near the observed CAT event over southwest of Korea. For the case at 0450 UTC 16 Feb 2003, vertically propagating mountain waves locally trigger shearing instability (Ri < 0.25) near the area where the background Richardson number is sufficiently small (0.25 < Ri < 1), and it induces turbulence near the observed CAT over the Eastern mountainous region of South Korea.

실제 날씨를 고려한 PV-MPPT 제어기의 최적 주기와 변량전압 (Optimum Control Period and Perturbation Voltage for PV-MPPT Controller Considering Real Wether Condition)

  • 류단비;김용중;김효성
    • 전력전자학회논문지
    • /
    • 제25권1호
    • /
    • pp.1-5
    • /
    • 2020
  • Solar power generation systems require maximum power point tracking (MPPT) control to operate PV panels at their maximum power point (MPP). Most conventional MPPT algorithms are based on the slope-tracking concept. A typical slope-tracking method is the perturb and observe (P&O) algorithm. The P&O algorithm measures the current and voltage of a PV panel to find the operating point of the voltage at which the calculated power is maximized. However, the measurement error of the sensor causes irregularity in the calculation of the generated power and voltage control. This irregularity leads to the problem of not finding the correct MPP operating point. In this work, the power output of a PV panel based on the P&O algorithm is simulated by considering the insolation profiles from typical clear and cloudy weather conditions and the errors of current and voltage sensors. Simulation analysis suggests the optimal control period and perturbation voltage of MPPT to maximize its target efficiency under real weather conditions with sensor tolerance.

실제 일사량 조건에서의 최적 MPPT 제어주기 (Optimum MPPT Control Period for Actual Insolation Condition)

  • 류단비;김용중;김효성
    • 전력전자학회논문지
    • /
    • 제24권2호
    • /
    • pp.99-104
    • /
    • 2019
  • Solar power generation systems require maximum power point tracking (MPPT) control to acquire maximum power using inefficient and high-cost PV modules. Most conventional MPPT algorithms are based on the slope-tracking concept. The perturb and observe (P&O) algorithm is a typical slope-tracking method. The two factors that determine the MPPT performance of P&O algorithm are the MPPT control period and the magnitude of the perturbation voltage. The MPPT controller quickly moves to the new maximum power point at insolation change when the perturbation voltage is set to large, and the error of output power will be huge in the steady state even when insolation is not changing. The dynamics of the MPPT controller can be accelerated even though the perturbation voltage is set to small when the MPPT control period is set to short. However, too short MPPT control period does not improve MPPT performance but consumes the MPPT controller resources. Therefore, analyzing the performance of the MPPT controller is necessary for actual insolation conditions in real weather environment to determine the optimum MPPT control period and the magnitude of the perturbation voltage. This study proposes an optimum MPPT control period that maximizes MPPT efficiency by measuring and analyzing actual insolation profiles in typical clear and cloudy weather in central Korea.

Hydro-meteorological analysis of January 2021 flood event in South Kalimantan Indonesia using atmospheric-hydrologic model

  • Chrysanti, Asrini;Son, Sangyoung
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.147-147
    • /
    • 2022
  • In January 2021 heavy flood affected South Kalimantan with causing many casualties. The heavy rainfall is predicted to be generated due to the ENSO (El Nino-Southern Oscillation). The weak La-Nina mode appeared to generate more convective cloud above the warmed ocean and result in extreme rainfall with high anomaly compared to past historical rainfall event. Subsequently, the antecedent soil moisture distribution showed to have an important role in generating the flood response. Saturated flow and infiltration excess mainly contributed to the runoff generation due to the high moisture capacity. The hydro-meteorological processes in this event were deeply analyzed using the coupled atmospheric model of Weather Research and Forecasting (WRF) and the hydrological model extension (WRF-Hydro). The sensitivity analysis of the flood response to the SST anomaly and the soil moisture capacity also compared. Result showed that although SST and soil moisture are the main contributors, soil moisture have more significant contribution to the runoff generation despite of anomaly rainfall occurred. Model performance was validated using the Global Precipitation Measurement (GPM) and Soil Moisture Operational Products System (SMOPS) and performed reasonably well. The model was able to capture the hydro-meteorological process of atmosphere and hydrological feedbacks in the extreme weather event.

  • PDF

LiDAR 측량 기반의 지형자료와 기상 데이터 관측시스템을 이용한 태양광 발전량 분석 (The analysis of Photovoltaic Power using Terrain Data based on LiDAR Surveying and Weather Data Measurement System)

  • 이근상;이종조
    • 지적과 국토정보
    • /
    • 제49권1호
    • /
    • pp.17-27
    • /
    • 2019
  • 본 연구에서는 LiDAR 측량을 활용하여 취득한 정밀 지형자료와 센서 기반의 기상데이터 관측시스템을 구축하여 태양광 발전량을 예측하는 연구를 수행하였다. 2018년 평균 일조시간은 4.53 시간으로 나타났으며, 태양광 발전량은 2,305 MWh으로 분석되었다. 그리고 태양광 모듈의 설치각도에 따른 태양광 발전량의 영향을 분석하고자 모듈 설치각도를 $10^{\circ}$ 간격으로 배치한 결과, 모듈 배치 각도 $30^{\circ}$에서 발전시간은 4.24 시간으로 나타났으며, 일 발전량과 월 발전량이 각각 3.37 MWh와 102.47 MWh로 가장 높게 평가되었다. 따라서 모듈 배치 각도를 $30^{\circ}$로 설계시 모듈 각도 $50^{\circ}$에 비해 발전효율이 약 4.8% 상승하는 것을 알 수 있었다. 또한 태양광 모듈의 설치각도에 따른 계절별 태양광 발전량의 영향을 분석한 결과, 날씨가 차가운 11월~2월까지는 모듈 각도가 큰 $40^{\circ}{\sim}50^{\circ}$가 태양광 발전량이 높게 나타났으며 날씨가 따뜻한 3월~10월까지는 모듈 각도가 작은 $10^{\circ}{\sim}30^{\circ}$가 태양광 발전량이 높게 나타남을 알 수 있었다.

태양광 및 풍력 하이브리드 발전 시스템에 관한 연구 (A study on solar-wind hybrid power generation system)

  • 오진석;조관준
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권8호
    • /
    • pp.1226-1231
    • /
    • 2009
  • 본 연구는 해양 시설물용 태양광-풍력 하이브리드 발전 전력 제어 시스템에 대한 연구를 수행하였다. 해양시설물은 대부분 태양광 기반의 발전 시스템으로 되어 있다. 이러한 태양광 발전 시스템은 흐른 날씨에는 전력 생산량이 감소한다. 이러한 발전 특성을 보완하기 위해 태양광과 풍력을 연계하는 시스템을 연구 하였다. LabVIEW를 이용하여 태양광과 풍력 발전 시스템을 시뮬레이션 하였다. 전력 특성을 반영하여 벅컨버터를 이용한 발전 전력 시스템을 개발하였다. 이를 실험을 통하여 풍력과 태양광 전력을 안정적인 충전을 수행하였다.

이상저온 발생 시점 확인을 위한 알고리즘 패턴 개발 (Development of Algorithm Patterns for Identifying the Time of Abnormal Low Temperature Generation)

  • 이정원;이충호
    • 산업융합연구
    • /
    • 제21권8호
    • /
    • pp.43-49
    • /
    • 2023
  • 2018년부터 기후변화에 따른 폭염과 한파에 의해 사회기반시설에 점증적으로 많은 피해를 미치고 있다. 최근 4년간 기후변화에 따른 영향 중에 냉해에 대한 피해가 매년 증가하여 특정 지역에 국한되었던 피해가 이제는 전국에 걸쳐서 나타나고 있으며, 이를 최소화하기 위한 각계각층의 전문가들에 의한 노력이 집중되고 있다. 그러나 불연속적으로 측정되는 데이터들 속에서 지역 특색을 반영하고자 하는 기존 연구들에서는 갑작스럽게 발생하는 이상 저온에 대한 실시간 관측 연구는 쉽지 않은 상황이다. 본 연구에서는 냉해 발생에 영향을 미치는 기상 데이터를 기준으로 냉해 피해가 발생하였던 시점의 기상 패턴을 탐색한 후 이상저온 발생 시점을 확인할 수 있는 알고리즘 패턴 개발을 하였다. 본 연구의 결과물은 과거의 데이터에 의존하지 않고 실시간으로 발생하는 데이터에 의한 이상저온이 발생한 시점을 시간 시점에서 확인할 수 있다는 점에서 지역적 기상 편차를 의식하지 않고 확인이 가능하다는 점에서, 이상저온 발생 시점 데이터를 확보할 수 있다는 점에서 관련 분야에 많은 도움이 될 것으로 기대할 수 있다.

온도규격 설정을 위한 동아시아 온도 분석연구 (A Temperature Analysis Study of East Asia for Generation of Temperature Specification)

  • 김인수;강치우
    • 한국군사과학기술학회지
    • /
    • 제5권3호
    • /
    • pp.11-22
    • /
    • 2002
  • In this paper, a statistical meaning that the 1% frequency value which is used as a basis for the temperature specification generation for weapon systems is similar to $3{\sigma}$ frequency value of a year is presented, and the theoretical reference for temperature specification generation is made. The new method which extracts the 1% frequency value from general weather data, not depending on long term temperature hour data, is established, and the temperature analysis result of East Asia is also presented by using this method. On the basis of these result, operational temperature for the weapon systems to be used in the area of East Asia is recommended.

태양광발전과 연료전지의 하이브리드 시스템 (Hybrid System of Solar Cell and Fuel Cell)

  • 황준원;최용성;이경섭
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.568-573
    • /
    • 2009
  • Because of environmental crisis, researchers are seeking and developing a new, clean, safe and renewable energy. Solar cell energy and fuel cell energy have inestimable development potential. The paper introduces hybrid photovoltaic-fuel cell generation systems supplying a remote power load and hybrid system of solar cell and fuel cell considering the advantages of stable and sustainable energy from the economic point of view. Fuel cell power system has been proven a viable technology to back up severe PV power fluctuations under inclement weather conditions. Fuel cell power generation, containing small land us, is able to alleviate the heavy burden for large surface requirement of PV power plants. In addition, the PV-fuel cell hybrid power system shows a very little potential for lifetime $CO_2$ emissions. In this paper shows the I-V characteristics of the solar module which are dependent on the power of the halogen lamp and the I-V characteristics of fuel cells which are connected in parallel. Also, it shows efficiency of the hybrid system.