• 제목/요약/키워드: Waveguide Sensor

Search Result 123, Processing Time 0.028 seconds

Measurement of Behaviors of Optical Filter using Evanescent Field Coupling between Single Mode Fiber and Multimode Planar Waveguide (단일모드 광섬유와 다중모드 평면도파로의 소산장결합을 이용한 광필터의 동작특성 측정)

  • Kim, Kwang-Taek;Yu, Ho-Jong;Song, Jae-Won;Kim, Si-Hong;Kang, Shin-Won
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.7
    • /
    • pp.42-49
    • /
    • 1999
  • In this paper, we proposed a simple measurement method to find the behaviors of the fiber-to-waveguide coupler. The polished fiber blocks and planar waveguides on silicon dioxide were fabricated independently and then optically coupled by physical pressure. Several kinds of polymer with different refractive indices were used for waveguide films. The proposed method makes it possible to measure the center wavelength, bandwidth, extinction ratio, and polarization dependence of the coupler during fabrication procedure. The wavelength sensitivity increased with refractive index of polymer. The symmetric planar waveguide structure and isotropic property of guiding materials reduced polarization dependent property. Insertion loss of the coupler was less than 0.5dB. It is expected that our measurement method is useful for developing various optical devices using evanescent coupling between polished fiber and planar waveguide such as optical modulators and filters etc.

  • PDF

Design of Integrated-Optic Biosensor Based on the Evanescent-Field and Two-Horizontal Mode Power Coupling of Si3N4 Rib-Optical Waveguide (Si3N4 립-광도파로의 두-수평모드 파워결합과 소산파 기반 집적광학 바이오센서 설계)

  • Jung, Hongsik
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.172-179
    • /
    • 2020
  • We studied an integrated-optic biosensor configuration that operates at a wavelength of 0.63 ㎛ based on the evanescent-wave and two horizontal mode power coupling of Si3N4 rib-optical waveguides formed on a Si/SiO2/Si3N4/SiO2 multilayer thin films. The sensor consists of a single-mode input waveguide, followed by a two-mode section which acts as the sensing region, and a Y-branch output for separating the two output waveguides. The coupling between the two propagating modes in the sensing region produces a periodically repeated optical power exchanges along the propagation. A light power was steered from one output channel to the other due to the change in the cladding layer (bio-material) refractive index, which affected the effective refractive index (phase-shift) of two modes through evanescent-wave. Waveguide analyses based on the rib optical waveguide dimensions were performed using various numerical computational software. Sensitivity values of 12~23 and 65~165 au/RIU, respectively for the width and length of 4 ㎛, and 3841.46 and 26250 ㎛ of the two-mode region corresponding to the refractive index range 1.36~1.43 and 1.398~1.41, respectively, were obtained.

Design and implementation of a X-band Doppler radar sensor using the homodyne detection (호모다인 검파방식을 이용한 X-밴드 도플러 레이더 센서의 설계 및 제작)

  • 장남영;최평석;은재정
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.2
    • /
    • pp.75-82
    • /
    • 2001
  • In this paper, a transmitter and a receiver using a Gunn diode and SBD was designed and fabricated in X-band. This system detects Doppler shift signal reflected by moving target through the homodyne detection, which is Doppler radar sensor for the measurement of the velocity of moving target. By the experimental results, the oscillating condition of the transmitter was satisfied at about the half wavelength between the supporting post of the Gunn diode in the waveguide and the waveguide short. And using the fabricated Doppler radar sensor, the velocity measurement deviation of moving target was 1.24%.

  • PDF

High Sensitivity Analysis of Optical Bio-Sensor based on Grating-Assisted Strip Directional Coupler (격자 구조형 스트립 방향성 결합기에 기초한 광 바이오-센서의 고 민감도 분석)

  • Kwang-Chun Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.6
    • /
    • pp.157-162
    • /
    • 2023
  • A highly sensitive refractive index bio-sensor based on grating-assisted strip directional coupler (GASDC) is proposed. The sensor is designed using two asymmetric strip waveguides with a top-loaded grating structure in one of the waveguides. Maximum light couples from one waveguide to the other at the resonance wavelength satisfying phase-matching condition (PMC), and it shows that the change in phase-matching condition with the change in refractive index of the analyte medium in the cover region can be used as a measure of the sensitivity. The proposed sensor will be an on-chip device with a high refractive index sensitivity, and the sensor configuration offers a low propagation loss, thereby enhancing the sensitivity. Furthermore, variation of the sensitivity with the waveguide parameters of sensor is evaluated to optimize the design.

Optimization of vertical SOI slot optical waveguide with confinement factor and sensitivity for integrated-optical biochemical sensors (구속계수와 감지도에 기반한 집적광학 바이오케미컬 센서에 적합한 수직 SOI 슬롯 광 도파로 최적화)

  • Jung, Hongsik
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.131-138
    • /
    • 2021
  • The optimization of the specifications of vertical silicon on insulator (SOI) slot optical waveguides suitable for integrated-optical biochemical sensors was performed through computational analysis of the confinement factor of the guided mode distributed in the slot in addition to analytical examination of the TE mode. The optimized specifications were confirmed based on sensitivity in terms of the change in the refractive index of the biochemical analyte. When the slot width, rail width, and height were set to 120 nm, 200 nm, and 320 nm, respectively, the confinement factor was evaluated to be about 56% and the sensitivity was at least 0.9 [RIU/nm].

Sensitivity Analysis for Specifications of Silicon-on-Insulator (SOI) Slot Optical Waveguide-based Single and Add-drop Channel Ring-resonant Biochemical Integrated Optical Sensors (SOI 슬롯 광 도파로 기반 단일 및 삽입-분기 채널 링-공진형 바이오·케미컬 집적광학 센서의 제원에 대한 감도 해석)

  • Jang, Jaesik;Jung, Hongsik
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.107-114
    • /
    • 2022
  • The effects of ring radius and coupling spacing on the free spectral range (FSR), full width at half maximum (FWHM), quality factor, and sensitivity of single-channel and add-drop channel slot ring resonators were systematically investigated using FIMMPROP and PICWAVE numerical software. The single-channel ring resonator exhibited better characteristics, namely, a wider FSR and narrower FWHM compared with the add-drop structure; thus, it was evaluated to be more suitable for biochemical sensors. The FSR, FWHM, quality factor, and sensitivity for a single channel ring resonator with a radius of 59.4 ㎛ and coupling gap of 0.5 ㎛ were 2.4 nm, 0.087 nm, 17677, and 550 [nm/RIU], respectively.

Development of a Ranging Inspection Technique in a Sodium-cooled Fast Reactor Using a Plate-type Ultrasonic Waveguide Sensor (판형 웨이브가이드 초음파 센서를 이용한 소듐냉각고속로 원격주사 검사기법 개발)

  • Kim, Hoe Woong;Kim, Sang Hwal;Han, Jae Won;Joo, Young Sang;Park, Chang Gyu;Kim, Jong Bum
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.1
    • /
    • pp.48-57
    • /
    • 2015
  • In a sodium-cooled fast reactor, which is a Generation-IV reactor, refueling is conducted by rotating, but not opening, the reactor head to prevent a reaction between the sodium, water and air. Therefore, an inspection technique that checks for the presence of any obstacles between the reactor core and the upper internal structure, which could disturb the rotation of the reactor head, is essential prior to the refueling of a sodium-cooled fast reactor. To this end, an ultrasound-based inspection technique should be employed because the opacity of the sodium prevents conventional optical inspection techniques from being applied to the monitoring of obstacles. In this study, a ranging inspection technique using a plate-type ultrasonic waveguide sensor was developed to monitor the presence of any obstacles between the reactor core and the upper internal structure in the opaque sodium. Because the waveguide sensor installs an ultrasonic transducer in a relatively cold region and transmits the ultrasonic waves into the hot radioactive liquid sodium through a long waveguide, it offers better reliability and is less susceptible to thermal or radiation damage. A 10 m horizontal beam waveguide sensor capable of radiating an ultrasonic wave horizontally was developed, and beam profile measurements and basic experiments were carried out to investigate the characteristics of the developed sensor. The beam width and propagation distance of the ultrasonic wave radiated from the sensor were assessed based on the experimental results. Finally, a feasibility test using cylindrical targets (corresponding to the shape of possible obstacles) was also conducted to evaluate the applicability of the developed ranging inspection technique to actual applications.

Design of a Rectangular Waveguide Antenna for Automotive Side and Rear Radar Sensor Applications (차량 측후방 레이더 센서용 직사각형 도파관 안테나 설계)

  • Lee, Jae-Min;Ryu, Hong-Kyun;Woo, Jong-Myung;Koo, Bon-Hee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.1
    • /
    • pp.42-52
    • /
    • 2012
  • In this paper, a waveguide antenna is designed and fabricated for side and rear radar sensor of vehicles in UWB (Ultra Wide Band) high band (center frequency : 9.5 GHz, -10 dB bandwidth : 600 MHz (6.4 %)). For the radar antenna, a probe fed rectangular waveguide antenna having simple structure and wide bandwidth is used. An important performance factor in this antenna is the isolation between transmitting (TX) and receiving (RX) waveguide antennas because this radar system uses TX and RX antennas separately. Thus the isolation between two antennas was simulated for E-plane and H-plane array. As a result, it was verified that the isolation of the H-plane array of the antennas is better than E-plane array, due to the TE10 mode. Therefore, H-plane arrayed waveguide antennas were mounted on a T-shaped radar module and performance of antennas was investigated. The -10 dB bandwidth of the TX and RX antenna mounted on T-shaped radar module was measured as 1000 MHz (10.52 %) and 1090 MHz (11.47 %) respectively and the isolation is less than -50 dB in the operation band. The peak gain is 7.65 dBi for the TX antenna and 7.26 dBi for the RX antenna and the beamwidth of H-plane of TX and RX antenna was measured as $64^{\circ}$ and $65^{\circ}$ respectively. Consequently, we verified that the proposed waveguide antenna is appropriate for a vehicle radar applications.

Study on the Feasibility of High-Temperature Immersion Ultrasonic Sensor with a Strip Waveguide (도파띠를 이용한 고온 액침 초음파센서의 가능성 연구)

  • Choi, M.S.;Lee, J.P.;Jung, T.E.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.3
    • /
    • pp.151-156
    • /
    • 1994
  • Exertion has been made to develop high-temperature (about $250{\sim}650^{\circ}C$) immersion ultrasonic sensor for the visualization of objects, temperature measurement, dimensional check, or nondestructive testing of welds under liquid sodium. In this study, the feasibility of the ultrasonic sensor taking advantage of a strip waveguide was confirmed by water-experiment. The lowest order of antisymmetric Lamb wave was used in the frequency range with negligible dispersion. This plate wave was excited in the stainless steel strip waveguide of 1.0mm thickness and 13mm width by the comb-structure transducer of 2.3MHz frequency. Its attenuation coefficient was 1.2dB/m in air and 380dB/m in water. The signal to noise ratio of 25dB was obtained from a planar reflector 270mm away from the beam aperture of $13mm{\times}39mm$ size.