공동주택 지하바닥 및 외벽부위 방수설계를 위한 방수공법 제안 (Waterproofing Method for Waterproof Design of Underground Floor and Exterior Wall of Residential Buildings)

  • 이정훈;서현재;최은규;송제영;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.233-234
    • /
    • 2019
  • Research has begun to change the waterproofing design of domestic underground structure parts from the current negative-side waterproof design to the positive-side waterproof design. For this, active review from the design stage to prevent the ingress of external ground water into the waterproofing measures of the underground of apartment buildings is needed. Therefore, in this study, proper waterproofing method for the major leaks identified in the previous studies and a waterproofing method for the waterproof design of the underground floor and the outer wall is proposed. It is hoped that a follow-up study, such as a review of field applicability, for the proposed methods will provide an alternative to secure leakage stability in waterproof design.

  • PDF

방수 스프레이 흡입 노출로 인한 급성 호흡기 중독 사례 및 원인 고찰 (Comprehensive Review of Acute Respiratory Failure Following Inhalation Exposure to Waterproofing Agents)

  • 박동욱;최예용
    • 한국환경보건학회지
    • /
    • 제38권6호
    • /
    • pp.451-459
    • /
    • 2012
  • Background: In Korea, a healthy 36-year-old man developed acute interstitial pneumonitis soon after inhaling a waterproofing spray which he had applied at home to his outdoor jacket. Objectives: The objectives of this study were to review cases of varying degrees of respiratory toxicity and poisoning in connection with the use of waterproofing spray and summarize major reasons for cases of poisoning. Methods: We searched articles reporting on a combination of a waterproofing agent and/or respiratory symptoms, including acute respiratory syndrome, lung injury, pneumonia, pulmonary toxicity, and respiratory disease. Results: We reviewed a number of cases of varying degrees of respiratory toxicity and poisoning resulting from inhalation of waterproofing spray containing fluorocarbon co-polymer, solvents and propellants reported in a variety of countries. The literature searches concluded that among the ingredients of waterproofing agents, fluorinated polymer may cause acute respiratory health effects. Conclusion: Environmental policy should be implemented in order to prevent consumers from using household and industrial products including waterproofing agents. In addition, a national surveillance system should be created to collect cases of poisoning caused by the use of consumer products.

콘크리트용 무기계 방수제의 침투깊이 측정방법에 관한 연구 (A Study on the Penetration Depth Measurement Methods of Inorganic Waterproofing Agent for Concrete)

  • 최연왕;오성록;박만석;김경환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.116-124
    • /
    • 2014
  • 콘크리트용 무기계 방수제는 내부 막을 형성하지 않기 때문에 무기계 방수제의 침투깊이 정량적으로 평가하기 어렵다. 그러나 무기계 방수제의 침투깊이 평가는 일관된 침투효율을 확보하는데 있어서 매우 중요한 평가지표 중 하나이다. 따라서 본 논문에서는 콘크리트용 무기계 방수제의 침투깊이 측정방법을 고안하였으며, 고안된 침투깊이 측정방법을 통하여 기존 무기계 방수제의 침투깊이를 평가하였다. 실험결과 고안된 무기계 방수제의 침투깊이 측정방법을 통하여 평가된 침투깊이는 90% 이상의 신뢰성이 있는 것으로 나타났다.

원형 접착 절연형의 복합 복층형 노출 방수제와 탈기관을 결합한 옥상 방수 공법에 관한 고찰 (A look at rooftop waterproofing methods that combine a circular adhesive insulated composite duplex exposure repellent with a airvent)

  • 김영석;전상훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.236-237
    • /
    • 2021
  • In the waterproofing of the rooftop of reinforced concrete buildings, it is difficult to solve perfectly according to the proficiency of waterproofing materials, methods, and mechanics. Therefore, this study applies a Tricot Fabric Mesh to the behavior of the bottom concrete. In addition, it responds to the behavior of the concrete cracking, and the waterproofing and protective layer has developed a method to provide convenience for rooftop floor use by adhesion between the base and the waterproof layer with the use of high viscosity urethane to effectively move the surface deformation and surface vapor and install a airvent device on the wall.

  • PDF

연질 및 경질 초속경도막방수재를 복합화한 옥상노출방수공법에 관한 실험적 연구(구조물 거동 대응성) (Development and Application of Unit Table Form using Euro Form for High-rise Building Construction)

  • 최은규;서현재;김범수;이정훈;송제영;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.141-142
    • /
    • 2017
  • New waterproofing technologies have emerged in the field of building waterproofing due to the recent diversification of the size and type of structures, the enhancement of required performance, and the diversification of new technologies (such as materials and methods)(Sheet waterproofing material, coating waterproofing material) is reduced, and composite waterproofing materials that utilize mutual benefits are widely used by compounding them (sheet+coating film, coating film+sheet). However, it is true that there is no evaluation method that can verify these composite waterproof materials, which is the most widely used at present, but the KS standard only specifies tests for individual materials However, there is a situation in which the countermeasures without a test method for composite waterproofing become sudden.

  • PDF

방수재료 및 공법의 내구성 평가를 위한 복합열화분석용 3차원 거동대응 시험결과 (A Study on the Analysis of 3 Dimensional Substrate Behaviour of Complex Environmental Deterioration and the Analysis of Results)

  • 송제영;서현재;최은규;이정훈;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.189-190
    • /
    • 2018
  • KS standards mostly relate to single component material evaluation, so in cases of underground structure environments, most cannot predict the existing composite forms of deterioration, resulting in the applied waterproofing materials becoming unable to respond to these damaging factors. Current domestic waterproofing market in Korea mainly uses single-ply waterproofing materials comprised of coatings or waterproof sheets and two or more-ply composite waterproofing methods. In order to evaluate these types of composite waterproofing systems, a new test equipment and method that incorporates various deterioration conditions (joint displacement, chemical exposure, water pressure etc) was developed. In a comparison testing, the results showed that flexible type materials have higher response performance towards joint displacement than the hardened material.

  • PDF

지붕용 톱코팅재의 내구성 향상에 관한 성능 및 평가방법에 관한 기초적 연구 (A Study on the Performance Evaluation Method of Waterproofing-Seal as Leakage Cracks Repairing Material using on the Underground Structure)

  • 박진상;강효진;오상근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.517-520
    • /
    • 2006
  • The waterproofing of Building on the roof has been exposed more underground or the other part of waterproofing than environmental factor(solar heat, UV, salt, acid rain, wind, temperature, snow, rain, etc.) or physical factor. So it must be have a waterproofing performance and it has a special technique for the maintaining of concrete durability. Therefore, exposed waterproof layer has to protected from UV, solar heat, rain and the outside environment also, to endurance durability methods spread face plate topcoat material on the waterproof layer. But, actuality faceplate waterproof layer of topcoat materials are unbearable to UV, solar heat and moisture etc. and it doesn't have adhesion with waterproof layer in the middle. So it happens to crack, separating and heaving etc. Therefore, in the study, we will suggest that using of the exposed roof waterproof layer topcoat materials test method manage rooftop waterproof layer for the durability and the stability.

  • PDF

AHP기법을 이용한 방수공법 선정 평가항목의 가중치 결정에 관한 연구 (A Research for Weight Decision of Waterproofing Methods Selection Evaluation Item using the AHP)

  • 최성민;임종권;오상근;서치호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.205-211
    • /
    • 2008
  • Recently, selects method of waterproofing where is suitable with method and material physical properties, construction technique, Productive technique and specifications and maintenance techniques evaluation for the same evaluation method is coming to be presented. Respects the application which select system is substantial objectively reflects a weight to evaluation item the research for is necessary. This research the evaluation which in order is effective and the decision-making to be possible about technically countermeasures for a quality security from waterproofing materials, method selection processes, clearly responsible dividing of construction and maintenance techniques. A sets weight of evaluation item for right select system, it stratify the causes which affect in priority based on AHP.

  • PDF

역수압 작용을 고려한 방수·방식재의 부착강도 시험방법에 관한 연구 (A Study on the Test Methods of Bond Strength in Waterproofing and Anti-corrosion Materials by Reversed Pressure)

  • 김명지;최수영;최성민;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.232-233
    • /
    • 2014
  • Recently, water treatment facility is usually eastablished in underground, and waterproofing and anti-corrosion materials for concrete structures applied water treatment tank is developing in various ways. However, as the limit of research focused on durability improvement of top coating material, it is insufficient to study on the adhesion strength between the concrete surface and primer. Therefore, there is to confirm the adhesion of between concrete surface and the three primers used as anti-corrosion waterproofing materials, and to investigate the properties of adhesion strength according to the condition such as wet codition and water pressure condition of the concrete surface in this study.

  • PDF

방수시트의 평행접합방법에 따른 인장성능 평가연구 (A Study on the Evaluation of Tensile Performance According to Pareral Jointing Methods of the Sheet Membrane Waterproofing System)

  • 이정윤;오미현;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술대회지
    • /
    • pp.39-44
    • /
    • 2004
  • A heat and room temperature construction method of asphalt have been mainly applying to rooftop waterproofing in concrete structure, and the rest construction method are sheet, membrane and mortar waterproofing construction method. In particular, joint method in sheet waterproof method is as overlap joint which on being reinforced with fiber and tape, have been applying for job site to mechanical fix using protection disk and anchorage and metal ironwork on the end of sheet. These construction method cause cutting off joint of sheet as behavior of structure according to repairs of sheet itself and thermal conduct, outdoor air environment. In conclusion, we analyzed and examined the application of various sheets and piece ashes about superior 'I' joint which divide from one and the other sheet and progressed about joint construction method of fixing method for overlap.