• Title/Summary/Keyword: Waterproof Design

Search Result 88, Processing Time 0.032 seconds

Consumer Needs and Pattern Sensibility of Jacquard fabrics for Raincoat (레인코트용 자카드 직물의 소비자 요구도 및 패턴 이미지 감성 평가)

  • Kim, Jeong-Hwa;Lee, Jung-Soon
    • Fashion & Textile Research Journal
    • /
    • v.16 no.4
    • /
    • pp.645-652
    • /
    • 2014
  • This study identifies consumer needs and a pattern sensory evaluation of jacquard fabrics for raincoats using quick-drying-absorbing polyester. We investigate the consumer's consciousness and raincoat improvements. Twelve kinds of jacquard fabrics were developed for use in this study. Developed jacquard fabrics were assessed subjectively by 152 university students using a 7-point scale of 26 consumer needs and 31 pattern image sensory descriptors. Data were analyzed by SPSS. The major results were: There was a need for consumers to improve the front fastener type, cuff fastener, mesh patch position, and raincoat pocket position. The most important parameter to choose raincoat fabric was waterproof and the other parameters were vapor-porous/water repellent, design, color, fashionability, air-permeability and easy-put on/off. The pattern image sensibility of jacquard fabrics was explained by seven factors: gorgeous, simple, cute, futuristic, ethnic, feminine, and cool. A higher pattern preference was found in the jacquard fabrics of unique, sporty, natural, luxurious, and trendy images. The pattern preference was predicted at 45.3% with gorgeous, simple, pure, cute, futuristic factors. The correlation coefficient between the pattern image sensibility factor 1 (gorgeous) and pattern preference was 0.674 and with factor 3 (cute) was 0.416, and with factor 6 (cool) was 0.209. The 4 factors (gorgeous, simple, cute, futuristic) were selected as a significant pattern image sensibility that influenced preference.

Development of 3-D Flow Model for Porous Media with Scenario-based Ground Excavation (지반굴착 시나리오 기반의 다공성 매질에 대한 3차원 유동해석모델 구축)

  • Cha, Jang-Hwan;Lee, Jae-Young;Kim, Woo-Seok
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.1
    • /
    • pp.19-27
    • /
    • 2017
  • In recent years, ground subsidence has been frequently occurred by underground cavities due to the excessive groundwater inflow, caused by poor construction and management, during tunnel excavation and underground structure construction. In this study, a numerical model (SEEFLOW3D) was developed to estimate groundwater fluctuations for saturated-unsaturated poros media, evaluates the impact on ground excavation with open cut and non-open cut scenarios. In addition, the visual MODFLOW was applied to demonstrate the verification of the model compared with both results. Our results indicated that the RMSE and NRMSE was obtained to range over -3.95~5.7% and 0.56~4.62%, respectively. The developed model was expected to estimate groundwater discharges and apply analysis tool for optimum design of waterproof wall in future.

A Study on the Properties of Anticorrosive for RC Structure (콘크리트구조물 보수용 방식피복재의 특성)

  • Moon, Han-Young;Shin, Dong-Gu;Kwon, Yong-Jin;Oh, Sang-Kun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.1
    • /
    • pp.251-258
    • /
    • 2005
  • Up until now, most protection design has been concerned primarily with concrete's exterior protection from corrosion, its waterproof ability and its reparability. However, there are many cases in which service life of the concrete is shortened because suitability of the type of concrete surface has not been thoroughly investigated in the development process. According1y, this paper presents the development and test of the material for its reparability and its protection against corrosion in the case of wet surfaces (i.e. water supply facilities, sewage systems, and port facilities) in this country. From the test, both A type and B type are excellent for durability in watertightness, chemical resistance and abrasion. Test results of adhesive strength over $15kgf/cm^2$ under both wet and dry conditions, curing conditions and various temperatures conditions were also achieved in field tests.

Performance Evaluation for the Application of Roof Green Box Unit System Combined with Engineering P.E.Waterproof and Root Penetration Sheet (엔지니어링 PE방수.방근시트가 결합된 박스 유닛형 옥상 녹화 시스템 적용을 위한 성능평가)

  • Oh, Chang-Won;Hong, Jong-Chul;Park, Ki-Bong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.2
    • /
    • pp.125-131
    • /
    • 2016
  • According to the increment of urban buildings, the demand of eco-environment space will be also increased. Therefore, the artificial ground green system on a roof will be supplied gradually. In this study, the concept of simplification, unification and prefabrication was widely applied to supply green system. Consequently, the box unit system with a continuous soil layer was developed, and adhesive property, wind resistance and insulation property of this system were evaluated for site application. As a results of adhesive property and wind resistance test, comparing with design wind pressure and wind velocity, this system was safe at the height of 100m building located in urban. In addition, results of temperature measurement for 120 days showed 17% higher insulation property at daytime and 45% higher insulation property at night than normal box unit system owing to continuous soil layer.

A Study on the Establishment of the Deterioration Process Model of Roof Waterproofing in the Education facilities (교육시설의 옥상방수 열화도 진행 모델에 관한 연구)

  • Lee, Kang-Hee;Chae, Chang-U;Ryu, Soo-Hoon
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.24 no.6
    • /
    • pp.11-18
    • /
    • 2017
  • Education facilities have much affect to make a good condition for the learning environment. Therefore, various approaches have been conducted to improve the physical, social and educational achievement. Especially, the physical aspect is very important to get rid of the building defect and improve the student their learning environment. For these, it needs to explain the performance and function of components and materials, which is linked with the deterioration degree. The deterioration degree is a imperative factor to make a decision whether the component would be repaired or not and to provide the repair scope of its component. In this paper, it aimed at making the deterioration degree model of roof proof under the hypothesis of which deterioration degree would be equal the repair cost at this time. Results of the study are shown that first, the $3^{rd}$ function is most proper to explain the deterioration degree model among 11 functions in view of resulted statistics. Second, the inflection of deterioration is shown at 15yr of the elementary school and 13yr of the middle and high school. This study has a limit of disclassification of the component or materials and it is, therefore, favorable to include the classification of waterproof material and work. These results would make a change from the breakdown maintenance to preventive maintenance and give a decent the learning environment for student.

Durability Evaluation of Hybrid Expansion Joint System with Improved Replacement (보수성을 개선한 복합형 신축이음장치(HRS) 내구성 평가)

  • Jung Woo Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.2
    • /
    • pp.1-7
    • /
    • 2023
  • Durability was evaluated by performing a full-scale vertical load fatigue test and a wheel load performance test on the HRS, which reduces the replacement time of the existing expansion joint and improves serviceability to allow partial replacement by lane. As a result of the vertical load fatigue test, the maximum stress of the rail-type expansion joint is 170 MPa, which is about 47.8% of the yield strength of the HRS expansion joint rail 355 MPa. The vertical load fatigue test of the HRS expansion joint with improved serviceability set the size and load of the load plate according to the road bridge design standards, did not show any fracture behavior in the vertical load fatigue test and the wheel load performance test 2 million times, and its durability and safety were verified.

Behavior Characteristics of Cement Bentonite Impervious Walls Related to Mixing Methods and Curing Time (강화벤토나이트 차수벽체의 배합방법 및 양생일에 따른 거동 특성)

  • Hwang, Jungsoon;Kim, Seungwook;Jung, Jungi;Lee, Seungjoo;Oh, Byeungsam;Baek, Seungcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.12
    • /
    • pp.45-54
    • /
    • 2016
  • In this study, the construction method of new underground continuos impervious wall that the bentonite slurry keeps the stability of excavated trench and the mixture of cement and bentonite plays a role as a constituent of impervious wall in the trench. The merit of homogeneity of the method so called as a cement-bentonite slurry wall enables to accurately make an estimation of hydraulic conductivity of the walls compared with that by other general grouting methods and to verify their waterproof efficiency without difficulty at the design stage. The use of cement-bentonite slurry walls for the containment of groundwater flow has also proven a cost-effective impervious wall technology by employing the simple combination of construction equipments and easy and fast construction procedures. The engineering characteristics of cement-bentonite impervious wall obtained by carrying out the laboratory experiments under various conditions. This study reveals the effect of variation of constituent materials and their mixing methods (Water-Cement-Bentonite) on the engineering characteristics of a composition. Also, this study makes some recommendations on the optimum mixing ratio and mixing sequence for the best quality at the site. That is the most important factors to estimate the construction cost and design of the technique. The comparison is lastly made to evaluate the effect of ordinary Portland and blast furnace slag cement as a bonding material on the behavior of impervious walls.

A Study on the Ground Reinforcement of Jeju Scoria Layer by Chemical Grouting (약액주입에 의한 제주도 송이지층의 지반보강에 관한 연구)

  • Yang, Kiho;Park, Jeongjun;Kim, Younghun;Byun, Yoseph;Lee, Eunjong;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.2
    • /
    • pp.75-82
    • /
    • 2014
  • Recently, public works becoming bigger in Jeju are implemented various kinds of ground reinforcement method including the chemical grouting method. In this study, we have been investigated on the proper material and the injection condition for the excellent injection effect and the excellent strength of injection material and the permanent waterproof and reinforcement through the experiment. The kind of injection material has been selected through the uniaxial compression test and the endurance test of injection material as the chamber test. An experiment was performed with model ground made of scoria, the injection performance of selected material has been identified through the evaluation test of injection range using the decision test of injection amount and the calibration chamber test. As a result of test, it has been analyzed that MSG appeared to have the excellent strength, durability and injection performance all compared with the ordinary cement, this result is judged to be possible as the ancillary data of design at time of design and construction with the chemical grouting method in the future.

Derivation of Flood Hazard Curves for SOC Facilities under Local Intensive Precipitation (LIP(극한강우) 조건하에서 중요 SOC 시설물에 대한 재해도 곡선 작성)

  • Kim, Beom Jin;Han, Kun Yeun*
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.183-194
    • /
    • 2019
  • In recent years, the risk of external flooding of major national facilities has increased significantly since 2000 due to the increase in local heavy rainfall events. For important domestic national facilities, it is necessary to analyze the risk of external flooding as flooding in major sites due to heavy rain can cause functional paralysis in major facilities and ultimately lead to massive trouble events. In order to manage the safety of main facilities and its related facilities at a high level, it is necessary to analyze the degree of disaster such as flood depth, flood flow rate, flood time and flood intensity when extreme floods (LIP) are introduced. In addition, the degree of vulnerability of these related facilities should be assessed and risk assessments should be reassessed through linkage analysis that combines the degree of disaster and vulnerability. By calculating a new flood hazard curve for the flood depth and flood intensity in major national facilities under the heavy rainfall conditions through this study, it is expected to be a basis for the waterproof design of important SOC facilities, flood prevention function design, advancement of flood prevention measures and procedures and evaluation of flood mitigation functions.

Determining of Ground Condition Criteria for Dam Reinforced RIM Grouting (댐체 강화 RIM부 그라우팅을 위한 지반상태 기준 결정)

  • Han, Kiseung;Lee, Donghyuk;Park, Duhee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.2
    • /
    • pp.181-186
    • /
    • 2022
  • Dam slope RIM is a highly important contact interface where the main body and the base surface are connected. In general, when the grouting for the slope of the dam structure is designed, it is planned using limited data (drilling, geological map, etc.). This makes it very difficult to accurately consider the original ground characteristics of the slope RIM grouting target, In addition, when the grouting volume planned during the design is drilled and injected into the original ground where the waterstop is secured, there is a possibility that the original ground with the waterstop is disturbed and the effect of the waterstop is rather diminished. In order to overcome such problems, it is more suitable to first consider geological conditions and determine whether to perform optimal grouting on the original ground through on-site repair tests before performing RIM grouting. In this paper, to determine the grouting of the RIM unit, a pilot hole water pressure test was performed on the rock of the slope in the target section. The analysis shows grouting volume of 1 Lugeon or less, and the cement injection amount also shows the injection result of 1 kg/m or less. In this case, performing grouting is rather counterproductive. This result can be evaluated through a rock of which some degree of order of mass is secured, as it is a dam design standard of 1 Lugeon or less when analyzed, using the results of visual observation and geological map creation during slope cutting. Therefore, in conclusion, it is preferable to make the decision for using RIM grouting on the slope of the dam body structure, based on 1 Lugeon in a rock state, and the cement injection amount also at 1 kg/m.