• 제목/요약/키워드: Water-saving valve

검색결과 16건 처리시간 0.02초

급수제어장치 설치에 따른 건축물의 에너지 효율 및 경제성 평가 (A Study on Economic Evaluation and Energy Efficiency for the Installation of Water Control Device in Building)

  • 박강현;차정훈;김수민
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.338-341
    • /
    • 2011
  • Water usage for cleaning the toilet bowl accounts for 27% of the total water usage. Water-saving valve that can select the amount of water for cleaning toilet bowl can be reduced expenditure. After installing water-saving valve, analysed the economic effects. Water-saving valves compared with flush valves, and researched the amount of water usage. Then analyzed fort he economic effects. Water-saving valve was used 5.6 ${\ell}/time$ for cleaning toilet bowl. In contrast, flush valve was consumed 8.4 ${\ell}/time$. Water-saving valve's water-saving rate was 33.3%. The initial payback period for Water-saving valve was 459.5 days. By a small investment in water saving valve, the economic benefits can be obtained.

  • PDF

세척밸브 급수제어장치 설치에 따른 경제적 효과 분석 (A Study on Economic benefits for Water Control Device Installed with a Flush Valve on a Toilet)

  • 박강현;김수민
    • 설비공학논문집
    • /
    • 제23권10호
    • /
    • pp.656-661
    • /
    • 2011
  • The amount of water resources that can be used tend to be decreased gradually. In contrast, the rapidly increasing water consumption is a problem that need to be addressed. Renovation and equipment replacement to improve energy efficiency and to reduce expenditure for building usage is required. But the excessive initial investment cost and the prolonged of pay back period may be uneconomical choice. Water usage for cleaning the toilet bowl accounts for 27%of the total water usage. Water-saving valve that can select the amount of water for cleaning toilet bowl can be reduced expenditure. After installing water-saving valve, analysed the economic effects. Water-saving valves compared with flush valves, and researched the amount of water usage. Then analyzed for the economic effects. Water-saving valve was used 5.6 ${\ell}$/time for cleaning toilet bowl. In contrast, flush valve was consumed 8.4 ${\ell}$/time. Water-saving valve's water-saving rate was 33.3%. The initial payback period for Water-saving valve was 459.5 days. By a small investment in water saving valve, the economic benefits can be obtained.

물 수요관리를 위한 물 사용실태 및 물 절약 설문조사 (Survey on water utilization status and saving mind for water demand management)

  • 임봉수;권정인;저소웅;이범희
    • 상하수도학회지
    • /
    • 제32권6호
    • /
    • pp.507-515
    • /
    • 2018
  • The results of the survey on water utilization status, the wasted water factor, the awareness, and the education and promotional activities of water saving in Daejeon City are as follows: The percentage of using tap valve with a closure was 66% when showering. 74% of water was used with closing the tap valve when washing faces with no water needed, it was still considered that there existed a wasting water. The most wasting reasons of water were found to be shower, bath, and laundry in order. In the awareness of practicing tap water saving, 9.1% of respondents acted actively, 53.4% of them were trying to practice it, and more than 63% had a positive awareness. In the contents of practicing saving water, locking water when soaping while showering, non-laundry of small quantity, and using cups when brushing teeth were top priorities. About 50% of the reasons for saving water was to practice purely saving water, when saving for economic help was excluded. The level of water saving awareness was not high when considering that the ratio of usage without water saving equipment and installation, and using method was relatively high when moving in. In order to make usage of water saving equipment more common, it was deemed necessary to provide information on the purchase of water saving equipment and to promote and educate the efficiency of saving of related products. More than about 90% of the respondents responded that water saving education or promotional activities had an effect of improving water saving awareness. The most effective method of education and promotional activities was found to be 40.4% by mass media activities, and 21.7% by promotions through mobile devices.

사무소 건물의 급수배관경 산정을 위한 동시사용유량에 관한 연구 (The evaluation of the simultaneous flow rate for sizing the water supply piping in the office building)

  • 이용화
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.511-517
    • /
    • 1999
  • Determining the simultaneous flow rate in any particular section of piping is the important step in order to determine the size of water supply piping. Now we are using the diversity curve of common water closet in order to determine the simultaneous flow rate of water supply piping, but there is a difference between a determined flow rate of general water closet and that of water closet for water saving. This study aims to find out the fixture unit of a flush valve type water closet for water saving in office building, and to determine the correlation between the fixture units and peak flow rates on the basis of the probability theory. A flush valve type water closet for water saving that have a 7.5 second duration of flush operation with an average design flow rate 72 $\ell$/fin was considered. Simulation results indicate that the number 5 is shown to be reasonable to the fixture unit of water closet for water saving. And the design can be undersized considerably with the revised diversity curves using modified fixture unit.

  • PDF

대용량 전기추진시스템 설계를 위한 제어알고리즘 개발 (Control Algorithm Development for Design of Cooling System in High-power Propulsion Motor)

  • 오진석;정성영;공영경;빈재구;김한호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권1호
    • /
    • pp.195-201
    • /
    • 2010
  • 본 논문에서는 에너지 절감 기능을 포함한 대용량 전기추진모터용 냉각 시스템을 제안한다. 기존 시스템에서 청수, 해수 펌프 속도는 일정하며, 냉각수의 과냉각을 방지하기 위해 3-way valve으로 열교환기에 들어가는 유량을 제어하였다. 그리하여 외부 해수 온도의 변화와 관계없이 펌프의 전력 사용량은 일정하였다. 제안된 시스템은 외부 해수 온도에 따라 청수, 해수 펌프의 속도를 인버터로 제어하여 3-Way valve를 최소한으로 동작하도록 함으로써 에너지 손실을 방지한다. 본 연구에서는 제안한 시스템의 효율성을 확인하기 위해 시뮬레이션을 통하여 검증하였다.

형상기억합금을 이용한 난방용 온도조절 밸브 및 원격 제어장치 개발 (Development of Heat Control Valve Using SMA and Remote Controller for House Heating System)

  • 최정주;염정국
    • 한국기계가공학회지
    • /
    • 제9권2호
    • /
    • pp.6-11
    • /
    • 2010
  • For the purpose of reducing the energy consumption in the house heating, the various devices have been developed. One of these is to control the flow in the heat pipe and the flow control valve using shape memory alloy(SMA) spring is proposed in our study. The proposed house heating system is to save the gas consumption and the remote control system is designed for the convenience of using the proposed valve. The developed valve consists of SMA spring, disk, return spring, and regulation handle. The regulation handle is for supplying the additional hot water and is controlled by remote-control-motor. In order to design the remote control system, the Zigbee wireless communication protocol is used. The performance of the proposed valve structure is shown through the experimental result.

공동주택 기계실 난방설비 운전 개선 연구 (A Study on Improved Operation of Apartment Heating System in a Machine Room)

  • 서정아;신영기;김용기;이태원
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.38-42
    • /
    • 2017
  • This study proposes an idea for energy saving in apartment machine rooms. A conventional district heating system is equipped with constant-flow pumps and bypass valves to regulate pump differential pressure. Each family unit is equipped with a constant-flow on/off valve. This leads to excessive hot water circulation and a high return temperature. To reduce energy loss, this study assumes that each family unit is renovated with a heating valve which regulates the return temperature at $35^{\circ}C$. The hot water supply pump is also replaced with a pump with an inverter to vary flow rate. Expected energy savings is then estimated from field test data. According to the results, pump electricity consumption was reduced by 6,100 kWh for a family unit building over about half a year. The supply temperature can also be lowered by $5^{\circ}C$, which can contribute to a production of electricity of 10.3 kWh/ton of hot water.

발전용 밸브누설 음향 진단 및 감시시스템 (Acoustic Valve Leak Diagnosis and Monitoring System for Power Plant Valves)

  • 이상국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.425-430
    • /
    • 2008
  • To verify the system performance of portable AE leak diagnosis system which can measure with moving conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured during operation on total 11 valves of the secondary system in nuclear power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, type of valve, pressure difference, valve size and fluid. The results of this field study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve. The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18 ". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

인버터구동 모터펌프를 이용한 아이스 슬러리형 빙축열시스템 전유량제어 운전시험 (Laboratory Test on Total Flow Control for Ice Slurry System with Inverter Fed Motor Pump)

  • 최병윤;이경호;이상렬;이학주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.260-265
    • /
    • 2001
  • This paper describes total flow control of an ice slurry system for pump energy saving. Similar turbo machinery has a characteristic that input power ratio is proportional to the three time of revolution speed ratio. To reduce the energy cost of brine pump in ice slurry storage systems, inverter is adapted instead of 3-way valve to control the speed of brine pump motor. One type of cooling load profile was used as driving load of the system, generated by a boiler and warm water storage tank. As results of the laboratory test, energy consumption and cost of the pump were reduced by 11.4%.

  • PDF

인버터 구동방식에 의한 실습선 냉각수 펌프의 에너지 절감 방법 (Put Investigation on the energy saving method using inverter driving for cooling pump at MMU training ship)

  • 임명환;안병원;김부기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권6호
    • /
    • pp.880-885
    • /
    • 2009
  • The ships have a lot of electric machinery needed to supply electricity from the moment of launching coming out of dry dock to docking at jetty. Thus, the ships always have to use alternator and electric machinery that has low efficiency under the low load. Many government service ships like the MMU training ship have been spending lots of time at jetty rather than sailing at sea. These ships are operated under the condition of low load due to the operation of basic machinery at jetty and electric machineries are driven with the status of low efficiency. This paper would suggest the energy saving method for these ships. The investigation describes that shore connection is a great asset to these ships and that the flow rate control by adjusting revolution with the adoption of inverter is better than flow rate control by using throttle valve to save energy. The result is based on the investigation of cooling pump at MMU training ship.