• Title/Summary/Keyword: Water spray system

검색결과 272건 처리시간 0.162초

전기 분무 시스템의 전기수력학적 특성 (Electrohydrodynamic Characteristics of an Electro-Spray System)

  • 이재복;황정호
    • 대한기계학회논문집B
    • /
    • 제23권8호
    • /
    • pp.1031-1039
    • /
    • 1999
  • Electrospraying comprises the generation of liquid droplets by applying a high voltage to the surface of a liquid. By monitoring the current and the flow rate it was possible to obtain a stable cone jet mode in a given condition. In this work the liquid contained NaCl particles resolved in distilled water. The NaCl particles increased concentration of the ionized solution and thus increased electrical conductivity of the liquid, which was inversely proportional to the flow rate in the cone jet mode. A number of sprayed droplets were sampled and dried enough, and then the size of NaCl particles were measured. The measured droplet diameter was a little larger than two theoretical diameters, Rayleigh diameter and mobility diameter.

400계열 FSTS의 내식성이 ABS 센서 링에 미치는 영향 (Effect on 400 series Ferrite Stainless Steel Corrosion Resistance of ABS Sensor Ring)

  • 양현수
    • 대한안전경영과학회지
    • /
    • 제2권3호
    • /
    • pp.197-210
    • /
    • 2000
  • In this paper, sensor ring for antilock brake system was studied using the 400 series ferrite stainless steel powder. Because of more excellent corrosion resistance and mechanical characteristics than iron, sensor ring has been manufactured by P/M(Powder Metallurgy) method 400 series ferrite stainless steel. the results are following. 1, Compared with sensor ring made by iron, 400 series ferrite stainless steel has shown a good corrosion resistance without an addition surface treatment. thus the decreasing production process has been obtained. 2. The products before sintering are much more corrodible in the condition of spray test of salt water and ammonia than humidity and nitrogen condition.

  • PDF

소규모 LNG 저장시설의 안전거리 기준 연구 (A Study on Safety Distance for Small Scale LNG Storage facility)

  • 오신규;조영도
    • 대한안전경영과학회지
    • /
    • 제16권4호
    • /
    • pp.185-191
    • /
    • 2014
  • In this study safety distance was investigated for small-scale LNG storage facilities in order to provide basic data for safety. The results are as follows; (1) For explosion pressure criteria, current criteria are reasonable, but water spray system should be recommended to LNG storage tank to ensure safety. (2) For criteria based on the results of the quantitative risk assessment, criteria applied to people are $5kW/m^2$ for radiation, LFL for dispersion, and 7kPa for explosion pressure. And criteria applied to facility are $37.5kW/m^2$ for radiation and 20 kPa for explosion pressure.

수술용 2파장 펄스형 Nd:YAG 레이저 개발 (Development of Surgical Two-wavelegth Nd:YAG Laser)

  • 윤길원;김홍식
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권4호
    • /
    • pp.491-498
    • /
    • 1996
  • The development of a compact two-wavelength Nd:YAG laser for dental and ENT applications is presented. The Nd:YAG resonator generates either 1.06$\mu$m or 1.32$\mu$m. The wavelength selection is made at the control panel. The Nd:YAG laser parameters at 1.06$\mu$m are ; the maximum pulse duration of 150$\mu$s, repetition rates of I-100Hz, and the maximum average power of 25W. At 1.32$\mu$m, the pulse duration is the same where the repetition rates and the maximum average power are I-30Hz and lOW respectively. High voltage power supply consists of a simmer module and two identical high voltage DC converters. In order to make a complete medical laser system, an optical fiber delivery unit, foot pedal and water spray handpiece are also developed. The wavelength selection is reliable since no movement of optical or mechanical components is required. The high voltage power supply is compact, easy to be maintained and applicable for other laser systems due to its modular design.

  • PDF

구획화재 시 국부복사열에 노출된 유리면의 수막접촉에 따른 급냉파열특성 관한 실험적 연구 (Experimental Study on Interaction of Water Sprayed Curtain on Hot Surface of a Window Glass and its Effects on Glass Surface Temperature in Room Fires)

  • 박형주;지남용
    • 한국화재소방학회논문지
    • /
    • 제17권4호
    • /
    • pp.124-130
    • /
    • 2003
  • 본 연구는 방화구획에 적용 가능한 수막형성유리벽에의 직근에 화원이 위치하는 경우 국부복사열에 의해 수막형성전 유리면이 가열된 상태에서 상부 수막분사노즐에서 분사되는 수막이 접촉함에 따른 급냉파열현상을 규명하기 위한 연구이다. 유리면 직근에서 국부복사열을 주는 실화재실험을 실시하여 분석하면 보통유리는 유리면 포면온도(가열측)가 $100^{\circ}C$를 넘는 경우에 수막을 접촉시킬 경우 파열이 발생하며, 강화유리는 유리 가열면 온도가 $250^{\circ}C$이상일 때 수막형성에 의한 급냉 파열이 발생함을 알 수 있었다. 향후 강화유리에 수막을 도포시키는 현재 방화구획에 사용되고 있는 유리의 대다수가 강화유리인 것을 감안하면 수막의 도포이전에 강화유리면의 온도가 $300^{\circ}C$이내에서는 수막을 유리면에 급속히 접촉시켜도 유리면의 급냉 파열이 일어나지 않음을 발견하였다. 따라서 일정한 공간구획 내에서 화재발생시 유리면의 직근에 화원이 위치하여 국부적으로 복사열을 가할 경우에도 화원상부 천정면에 설치된 감지시스템에 의해 한계온도이전에 수막형성시스템을 작동시켜 급냉파열현상을 발생시키지 않는다면 수막형성유리벽을 실제 방화구획의 경계벽으로 사용하는데 있어서 예측가능한 장애요인을 제거하는 데 비약적인 공헌을 한 것에 그 의미를 둔다.

Experimental Investigation of Coupling Effects between Particle Size and Temperature on the Thermal Conductivity of Alumina Nanofluids

  • Lee, Ji-Hwan;Jang, Seok Pil;Lee, Seung-Hyun;Park, Yong-Jun;Kim, Dong Jin;Koo, Jaye
    • 한국분무공학회지
    • /
    • 제19권4호
    • /
    • pp.174-181
    • /
    • 2014
  • This study investigates the effects of nanoparticle size and temperature on the thermal conductivity enhancement of water-based alumina ($Al_2O_3$) nanofluids, using the centrifuging method and relative centrifugal forces of differing magnitude to produce nanofluids of three different particles without involving any dispersants or surfactants. We determined the coupling dependency in thermal conductivity enhancement relative to nanoparticle size and temperature of the alumina nanofluids and also experimentally showed that the effect of temperature on thermal conductivity is strongly dependent on nanoparticle size. Also, our experimental data presented that the effective medium theory models such as the Maxwell model and Hasselman and Johnson model are not sufficient to explain the thermal conductivity of nanofluids since they cannot account for the temperature- and size-dependent nature of water-based alumina nanofluids.

EHC 기반 Urea-SCR 시스템 히터 표면온도 분포의 1-D 모델링 (1-D Modeling of Heater Surface Temperature Distribution in EHC-based Urea-SCR System)

  • 박선홍;손지현;문석수;오광철;장성욱;박성서
    • 한국분무공학회지
    • /
    • 제27권1호
    • /
    • pp.11-17
    • /
    • 2022
  • In upcoming Post Stage-V and Tier 5 regulations of construction machineries, nitrogen oxide (NOx) emissions are strictly limited in cold start conditions. In response to this, a method of improving NOx conversion efficiency has been applied by installing an electric heating catalyst (EHC) in front of conventional urea-SCR systems so that the evaporation and thermal decomposition of urea-water solution can be promoted in cold start conditions. In this strategy, the evaporation and thermal decomposition of urea-water solution and corresponding NOx conversion efficiency are governed by temperature conditions inside the EHC. Therefore, characterizing the temperature distribution in the EHC under various operating conditions is crucial for the optimized operation and control of the EHC in Urea-SCR systems. In this study, a 1-D modeling analysis was performed to predict the heater surface temperature distribution in EHC under various operating conditions. The reliability of prediction results was verified by comparing them with measurement results obtained using an infrared (IR) camera. Based on 1-D analysis results, the effects of various EHC operation parameters on the heater surface temperature distribution were analyzed and discussed.

다이케스팅 이형재 분사 로봇시스템의 터빈 모듈 설계에 관한 연구 (Study of Turbine Module Design for Die Casting Mold Release Injection Robot System)

  • 최현진;손영범;박철우;이승용;최성대
    • 한국기계가공학회지
    • /
    • 제14권5호
    • /
    • pp.1-7
    • /
    • 2015
  • Cleaning by injecting dry ice and water is a generally adopted trend these days to clean molds (injection, diecasting foundry, press, rubber mold, etc). This cleaning method is performed manually, or by installing multiple high pressure spray nozzles. We have manufactured a turbine cleaning module device that is able to clean diecasting modules at any position and angle in the space by mounting an articulated robot instead of the existing pipe type injection nozzle, to minimize lead time and enhance working yield of the cleaning process. In this paper, we analyzed process factors that are required to design the turbine module by reviewing number of revolution, and results according to different blade angles and thicknesses of the mold release injection turbine module, using computational fiuid dynamics (CFD).

Intelligent Tuning of the Two Degrees-of-Freedom Proportional-Integral-Derivative Controller On the Distributed Control System for Steam Temperature Control of Thermal Power Plant

  • Dong Hwa Kim;Won Pyo Hong;Seung Hack Lee
    • KIEE International Transaction on Systems and Control
    • /
    • 제2D권2호
    • /
    • pp.78-91
    • /
    • 2002
  • In the thermal power plant, there are six manipulated variables: main steam flow, feedwater flow, fuel flow, air flow, spray flow, and gas recirculation flow. There are five controlled variables: generator output, main steam pressure, main steam temperature, exhaust gas density, and reheater steam temperature. Therefore, the thermal power plant control system is a multinput and output system. In the control system, the main steam temperature is typically regulated by the fuel flow rate and the spray flow rate, and the reheater steam temperature is regulated by the gas recirculation flow rate. However, strict control of the steam temperature must be maintained to avoid thermal stress. Maintaining the steam temperature can be difficult due to heating value variation to the fuel source, time delay changes in the main steam temperature versus changes in fuel flow rate, difficulty of control of the main steam temperature control and the reheater steam temperature control system owing to the dynamic response characteristics of changes in steam temperature and the reheater steam temperature, and the fluctuation of inner fluid water and steam flow rates during the load-following operation. Up to the present time, the Proportional-Integral-Derivative Controller has been used to operate this system. However, it is very difficult to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error. This paper focuses on the characteristic comparison of the PID controller and the modified 2-DOF PID Controller (Two-Degrees-Freedom Proportional-Integral-Derivative) on the DCS (Distributed Control System). The method is to design an optimal controller that can be operated on the thermal generating plant in Seoul, Korea. The modified 2-DOF PID controller is designed to enable parameters to fit into the thermal plant during disturbances. To attain an optimal control method, transfer function and operating data from start-up, running, and stop procedures of the thermal plant have been acquired. Through this research, the stable range of a 2-DOF parameter for only this system could be found for the start-up procedure and this parameter could be used for the tuning problem. Also, this paper addressed whether an intelligent tuning method based on immune network algorithms can be used effectively in tuning these controllers.

  • PDF

수처리 시설물 콘크리트 표면처리 방법에 따른 금속용사 피막의 부착성능 평가에 관한 실험적 연구 (An Experimental Study on Evaluation of Bond Strength of Arc Thermal Metal Spaying According to Treatment Method of Water Facilities Concrete Surface)

  • 박진호;이한승;신준호
    • 한국건축시공학회지
    • /
    • 제16권2호
    • /
    • pp.107-115
    • /
    • 2016
  • 본 연구에서는 금속용사 시스템을 수처리 시설 콘크리트 구조물의 방수/방식 공법으로 사용하기 위하여 콘크리트 표면처리 방법에 따른 기초적 성능 평가 실험을 진행하였다. 실험결과 Sa-P-R-(S)(샌딩-침투성표면강화제-조면형성제-봉공처리)의 경우가 3.57MPa로 가장 높은 부착성능을 나타냈다. 부착성능이 확보된 면처리 방법을 기반으로 투수성, 투기계수 측정실험을 진행하였다. 실험 결과 Sa-P-R-(S)의 경우가 각각 $0.68{\times}10^{-8}cm/sec$, $0.45{\times}10^{-16}m^2$로 가장 우수한 성능을 나타내었다. 또한 SEM분석 결과 침투성 표면강화제를 도포한 실험체가 그렇지 않은 경우에 비해 콘크리트의 미세 구조가 더 치밀한 것을 확인 할 수 있었으며, 이러한 구조로 인해 침투제를 도포한 경우의 실험체에서 가장 높은 부착성능이 나타난 것으로 판단된다. 따라서 콘크리트의 표면 처리 방법은 금속용사 시스템을 적용하는데 있어, 매우 중요한 영향을 미치는 것으로 판단되며, 본 연구를 통하여 Sa-P-R-(S)의 경우가 수처리 시설 콘크리트 구조물의 적용하기에는 가장 적합한 면처리 방법이라 판단된다.