• 제목/요약/키워드: Water quality measurement

검색결과 537건 처리시간 0.029초

2차원 이송-확산 모형을 이용한 취수장 유입 수질 예측 (Water Quality Modeling for Intake Station by 2-dimensional Advection-Dispersion Model)

  • 김재동;김지훈;김영도;송창근;서일원
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.667-679
    • /
    • 2011
  • In this study, the influences of pollutant from Dae-po Stream and So-gam Stream located at the downstream of Nak-dong River on the water quality at Mul-geum water intake station were analyzed using RAMS model. Field measurements of velocity by ADCP, and water quality distribution of BOD and TP by water sampling were carried out to present the input and verification data for numerical simulations. The comparison between RAM2 and ADCP measurement, which aimed for the analysis of 2-D velocity distribution around Mul-geum water intake station showed that two results matched well along the spanwise direction. The prediction of pollutant concentration by RAM4 agreed fairly well with the measured data except for the points nearby right banks in the vicinity of tributary pollutant source. Flushing effect by the increase of mainstream discharge in Nak-dong River was analyzed to provide the damage mitigation in preparation for the accidental water pollution. With increasing mainstream discharge, high velocity and increased water quantity induced increasing dilution effect, thereby decreasing the inflow pollutant concentration rapidly.

완도 육상 해수 양식장과 조위관측소의 수질 환경 데이터 비교 분석 (The Comparative Analysis of Water Quality Environment Data of Wando Onshore Seawater Farm and Tidal Observatory)

  • 예성빈;권인영;김태호;박정선;한순희;정희택
    • 한국전자통신학회논문지
    • /
    • 제16권5호
    • /
    • pp.957-968
    • /
    • 2021
  • 육상 양식장 수질 모니터링 시스템의 데이터 신뢰도 향상 및 효율적 시스템 운영을 위하여 현재 시험 운영중인 육상 해수 양식장과 해양환경정보망(완도조위관측소)의 수질 데이터를 비교 분석한다. 또한 수질 모니터링 시스템의 데이터 오류를 제거하고, 측정 데이터의 신뢰도를 높이는 방법으로 데이터 유효성 검증, 데이터 범위 필터, 데이터 변위 검사를 적용하여 비교 분석한다.

산업폐수 방류수의 생태독성 평가 (Ecotoxicity Assessment of Industrial Effluent in Korea)

  • 오경택;김지원;김우근;이순애;윤홍길;이성규
    • 한국물환경학회지
    • /
    • 제22권1호
    • /
    • pp.37-44
    • /
    • 2006
  • Ecotoxicity assessments of 90 selected effluents of 22 industry types from 2002 to 2004 in Korea were evaluated by a toxic battery of bioassay test using fish Oryzias latipes, invertebrate Daphnia magna, algae Selenastrum capricornutum and bacteria Vibrio fischeri with the physicochemical measurement items and permit concentrations on the present Water Quality Conservation Act in Korea. Total toxic unit (${\Sigma}TU$) of 8 industry types of 22 industry types by the toxic battery appeared in order of the value site as follows; Pigment Dye Manufacturing (${\Sigma}TU$ 217.1) > Textile and Dye (${\Sigma}TU$ 39.3) > Semiconductor Electronic Manufacturing (Small) (${\Sigma}TU$ 25.6) > Wastewater and Sewage Treatment Plants (${\Sigma}TU$ 25.4) > Coating (${\Sigma}TU$ 23.8) > Leather Skin Manufacturing (${\Sigma}TU$ 18.0) > Synthetic Resin Manufacturing (${\Sigma}TU$ 15.6) > Assemble Metal Manufacturing (${\Sigma}TU$ 10.7). Our results demonstrate that ecotoxicity assessment, by bioassay test, is effective and practical for industrial wastewater management for 90 selected effluents with the limitation of the physicochemical permit. Among 90 effluents, 9 samples failed physicochemical permit limitation and 81 passed it. In result of ecotoxicity assessment of 90 effluents by the toxic battery, 76 effluents exhibited ecotoxicity and the others did not. The physicochemical measurement items and permit concentrations on the present Water Quality Conservation Act in Korea were low related to the ecotoxicity value by the toxic battery and appeared limited for water quality management to water-ecosystem and environment-friendly management of water.

부하지속곡선을 이용한 중랑천의 유량 조건별 수질특성 평가 (Assessment of the Water Quality of Jungnang Stream by Flow Conditions Using Load Duration Curve)

  • 최경완;신경용;이형진;전상호
    • 한국환경보건학회지
    • /
    • 제38권5호
    • /
    • pp.438-447
    • /
    • 2012
  • Objective: The objective of this study was to suggest a method through which load duration curve was used to assess the achievement of water quality targets in accordance with the criteria for pollutant load depending on flow rate variation. Methods: The stage-discharge curve and flow duration curve of Jungnang Stream were deduced. Using water quality targets and measurement of the stream, the flow duration curve was also drawn. Based on these, the feasibility of achievement of water quality targets in respect to flow rate was assessed. Results: In terms of the load duration curve of the stream, it was observed that excess of criteria for concentrations of $BOD_5$, $COD_{Mn}$ and SS frequently occurred. On the other hand, when the flow rate was low, the concentrations of T-N and T-P exceeded the criteria. Conclusions: Through the load duration curve, the overall water quality of Jungnang Stream was understood. When the flow rate is high, management of point source of $BOD_5$, $COD_{Mn}$ and SS is needed to achieve water quality targets for Jungnang Stream. On the other hand, when the flow rate is low, the management of non-point source T-N and T-P is necessary to attain the water quality goal.

저수지 플러싱 방류가 하류 수질에 미치는 영향 모의를 위한 수질모델의 성능 평가 (Evaluation of the Performance of Water Quality Models for the Simulation of Reservoir Flushing Effect on Downstream Water Quality)

  • 정용락;정세웅;윤성완;오동근;정희영
    • 한국물환경학회지
    • /
    • 제25권1호
    • /
    • pp.48-57
    • /
    • 2009
  • A two-dimensional (2D), laterally-averaged hydrodynamic and water quality model, CE-QUAL-W2 was applied to evaluate the performance on simulating the effect of flushing from Daecheong Reservoir on the downstream water quality variations during the flushing events held on November, 2003 and March, 2008. The hydraulic and water quality simulation results were compared with field measurement data, as well as a one-dimensional (1D), unsteady model (KORIV1) that revealed limited capability in the previous study due to missing the resuspension process of river bottom sediments. The results showed that although the 2D model made satisfactory performance in reproducing the temporal variations of dissolved matters including phosphate, ammonia and nitrate, it revealed poor performance in simulating the increase of biological oxygen demand and suspended sediment (SS) concentrations during the passage of the flushing flow. The reason of the error was that the resuspension process of the 2D model is only the function of shear stress induced by wind. In reality, however, as shown by significant correlation between bottom shear stress ($\tau$) and observed SS concentration, the resuspension process can be significantly influenced by current velocity in the riverine system, especially during flushing event. The results indicate that the resuspension of river bottom materials should be incorporated into the water quality modeling processes if $\tau$ is greater than a critical shear stress (${\tau}_c$) for better simulation of flushing effect.

수질자동모니터링시스템의 설치 현황과 전망 (A Real Time Monitoring for Water Quality of River)

  • 류재근
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.1-11
    • /
    • 2004
  • Water quality is monitored at 1,837 points which are streams and sources for water supply in Karea. The monitoring carry out the measurement of 16 parameters of pH, BOD, SS, DO and so on with once a month, and of other parameters such like heavy metal with once a quarter. But most of the monitoring is carried out uncontinuously, so it is very difficult to understand exactly the changes of water quality compared with continuous monitoring. Therefore, real time monitoring system was equipped with basic parameters such as pH, temperature, DO, turbidity and electric conductivity at 25 major sources of water supply after installation of Noryangjin and Dukdo in 1974. But the systems have some problems which cannot be considered the sampling sites to represent for water quality of stream of lake, and can be caused a change of water quality by long distance from analyzer to intake pipe. Therefore, it has carefully to evaluate selection of sample sites for real time monitoring system. Also, problems on the area has been to identify which parameters are best suited to monitoring stream of lake water and the differences, of analyzing results compared with manual analyzing. This paper presents some approaches to handle such problems, namely selection of sampling site and measurable parameters, to connect with bio-monitoring system solving a Limitation of measurable parameters, The bio-monitoring system of an early alarm that is desirable to perceive a toxic material inflow into stream can be applied to continuos water quality monitoring system effectively. Also, this paper presents to build a on line system transmitting immediately from a mobile analyzer house or container to main monitoring center the results of analyzer by a telemeter.

A Study on integrated water management system based on Web maps

  • Choi, Ho Sung;Jung, Jin Young;Park, Koo Rack
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권8호
    • /
    • pp.57-64
    • /
    • 2016
  • Initial prevention activities and rapid propagation conditions is the most important to prevent diffusion of water pollution. If water pollutants flow into streams river or main stresm located in environmental conservation area or water intake facilities, we must predict immediately arrival time and the diffusion concentration to the proactive. National Institute of Environmental Research developed water pollution incident response prediction system linking dam and movable weir. the system is mathematical model which is updated daily. Therefore it can quickly predict the arrival time and the diffusion concentration when there are accident of oil spills and hazardous chemicals. Also we equipped with mathematical model and toxicity model of EFDC(Environmental Fluid Dynamics Code) to calculate the arrival time and the diffusion concentration. However these systems offer the services of an offline manner than real-time control services. we have ensured the reliability of data collection and have developed a real-time water quality measurement data transmission device by using the data linkage utilizing a mode bus communication and a commercial SCADA system, in particular, we implemented to be able to do real-time water quality prediction through information infrastructure of the water quality integrated management business created by utilizing the construction of the real-time prediction system that utilizes the data collected, the Open map, the visual representation using charts API and development of integrated management system development based on web maps.

관거 정비에 따른 하수발생특성 분석 (Analysis of the wastewater characteristics variation in sewerage by rehabilitation)

  • 정시몬;박인혁;박정하;하성룡
    • 상하수도학회지
    • /
    • 제23권3호
    • /
    • pp.287-293
    • /
    • 2009
  • The study involved the measurement of flowrate and BOD in the Yeoju area and analyzed annual sewerage data by the I/I analysis technique which is common in Korea. The results of this study are as follows. The I/I for the Y-1 site before maintenance and after the completion of the whole process was reduced from 62% to 16.1% respectively with respect to maximum sewage flow per day. The average quality of water increased. The study measured the Y-2 site from a point of time corresponding to an 80% process rate and its I/I rate went up a little from 8.5% to 11.5%. At the Y-3 site, the I/I rate went up a little from 11% to 13.8%, while little change was noted in the average water quality. At the Y-4 site, the I/I rate was reduced from 43% to 16.9% and its average water quality went up. At the Y-5 site, the I/I quantity went up a little however its average water quality also went up largely. Therefore, it was concluded that the Y-5 site showed great improvement due to the sewer pipe maintenance.

저가형 냉각탑 자동 수질 진단 시스템 개발 (Development of a Low-cost Automatic Water Quality Diagnosis System for Cooling Towers)

  • 김정환;박한빈;강태삼;박정근
    • 센서학회지
    • /
    • 제23권1호
    • /
    • pp.58-65
    • /
    • 2014
  • We developed a low-cost automatic diagnosis system for water quality in cooling towers to measure the concentrations of key ingredients such as $Ca^{2+}$, $Cl^-$, $PO{_4}^{3-}$, and $Fe^{2+}$. $Ca^{2+}$, and $Cl^-$ are the main factors that cause the generation of scale, corrosion, and sludge in water pipes. $PO{_4}^{3-}$ prevents corrosion, sludge and scale by inhibiting the ions (i.e., $Ca^{2+}$, $Cl^-$) from sticking to the pipes. $Fe^{2+}$ is an indicator of pipe corrosion. The proposed system consists of a microprocessor, a specimen container and heater, a precision pump, relays and valves, LED optical sources, and photo detectors. It automatically collects water samples and carries out pretreatment for determining the concentration of each chemical, and then estimates the concentration of each ion using low-cost LED optical sources and detectors. Experimental results showed that the accuracy of the proposed system is sufficiently high for water quality diagnosis and management of cooling towers, demonstrating the possibility of the proposed system's wide usage in real environments.

장기간 유량측정 자료를 이용한 경안천의 부하지속곡선 특성 (Analysis of Load Duration Curve Using Long Time Flow Measurement Data of Kyeongancheon)

  • 노창완;권필상;정우석;이명구;조용철;유순주
    • 환경영향평가
    • /
    • 제28권1호
    • /
    • pp.35-48
    • /
    • 2019
  • 장기간 유량측정과 수질분석은 수질오염총량관리제도 유역의 목표수질과 허용 부하량을 결정하기 위하여 필요하다. 목표수질 달성여부를 평가하는데 사용되는 부하지속곡선은 유량과 수질간의 관계를 설명하고, 유량조건별 오염부하량 특성을 평가한다. 경안천의 부하지속곡선은 경안천 목표수질과 2006년부터 2015년까지 연평균 8일 간격으로 측정한 유량자료를 이용한 유량지속곡선에 의해서 작성되었다. 연구결과 경안천은 갈수량 구간에서 목표수질을 초과하여 점오염원에 대한 관리가 필요한 것으로 분석되었다. 또한, 연중 3월에서 6월 사이의 기간 동안에만 목표수질을 초과하는 것으로 나타나 이 기간 동안 경안천의 목표수질을 달성하기 위한 체계적인 유역 관리가 필요한 것으로 판단된다.