• 제목/요약/키워드: Water quality guideline

검색결과 115건 처리시간 0.027초

국내 농업용수의 유해중금속 수질권고기준 도출 (Derivation of Agricultural Water Quality Guidelines for Heavy Metals in Korea)

  • 안윤주;백용욱;이우미;윤춘경
    • 한국물환경학회지
    • /
    • 제24권5호
    • /
    • pp.533-536
    • /
    • 2008
  • Korean water quality guidelines for agricultural were derived to protect agricultural water uses according to the Canadian methodology. The adverse effect of heavy metals in agricultural water was of concern due to its persistence, bioaccumulation and ecotoxicity to crop plants. The ecotoxicity data of cadmium, copper, lead, and zinc were collected for the crops grown in Korea, and used to estimate the species maximum acceptable toxicant concentration (SMATC), which corresponds to the water quality guideline. Values of irrigation per year and soil bulk density were revised to reflect the Korean situation. The estimated guideline values for cadmium, copper, lead, and zinc were 0.01, 0.5, 0.1, and 1.0 mg/L, respectively. These values are in agreement with the agricultural water quality guidelines of foreign countries and current Korean water quality standard for the protection of public health. Current water quality standards in agricultural uses were for management of public water resource, and was not prepared to protect crop plants from contaminants. The results of this study will be a basis for the designation of Korean water quality guidelines for the protection of agricultural water uses in the future.

논의 수질정화 기능 분석 (Analysis of the Function of the Paddy-field in Purifying Water Quality)

  • 김현수;김영일;김진수
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.599-602
    • /
    • 2003
  • The objective of this study is to analyze the function of the paddy-field in purifying water quality. This study was carried out is based on the data in the six case studies. To improve purification function of paddy field, the following farming management is required. 1) A guideline to control the inlet and outlet of the paddy plot is need to minimize drainage water by means of a reasonable irrigation management. 2) A guideline for fertilizer application in consideration of loading nutrients dissolved in irrigation water. 3) The reuse system of agricultural drainage water is required to minimize impacts on water quality of surface water(reservoir and river).

  • PDF

WQV 기반 비점오염저감시설의 강우유출수 처리비 경험공식의 개선 (The Improvement on the Empirical Formula of Stormwater Captured Ratio for Water Quality Volume Based Non-Point Pollutants Water Quality Control Basins)

  • 최대규;박무종;박배경;김상단
    • 한국물환경학회지
    • /
    • 제30권1호
    • /
    • pp.87-94
    • /
    • 2014
  • According to the technical guideline of water pollutant load management, the rainfall captured ratio which can be estimated by the empirical formula is an important element to estimate reduction loads of non-point pollutants water quality control basin. In this study, the rainfall captured ratio is altered to stormwater captured ratio considering its meaning in the technical guideline of water pollutant load management, and the new empircal formula of stormwater captured ratio is suggested. In order to do this, we calculate stormwater captured ratio by using the hourly rainfall data of seven urban weather stations (Busan, Daegu, Daejeon, Gangreung, Seoul, Gwangju, and Jeju) for 43 years. The regression coefficients of the existed empirical formula cannot reflect the catchment properties at all, because they are fixed values regardless of regions. However the empirical formula of stormwater captured ratio has flexible regression coefficients by runoff coefficient(C), so it is allowed to consider the characteristics of runoff in catchment. It is expected that reduction loads of storage based water quality control basin can be more reasonably estimated than before.

공동주택 지역난방 수질기준 설정에 관한 연구 (A Development of the Guideline for the Heating Water Quality in Apartment Houses with District Heating System)

  • 김용기;이태원;우달식;오준;안창구
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.493-498
    • /
    • 2008
  • Particles or deposit formed by corrosion of the pipe material bring about bad influences on the heating systems with inconvenience, energy loss and so on. In order to obtain the non-corrosive environments, the circulation hot water should properly be treated in several ways to satisfy one or more conditions of the followings: suitable pH-level, low hardness, low oxygen content, low conductivity, low level of chlorides and sulphur compounds and low level of solid particles. This experimental study was carried out to develope the new guidelines on the optimal water quality and directions for water quality management in heating systems. As results, it was recommended that the heating water be maintained pH-level not less than 8, hardness contents as $CaCO_3$ no more than 50 mg/L, turbidity no more than 10 NTU and T-Fe contents 1 mg/L below.

  • PDF

수질자동측정망 자료의 신뢰성 제고를 위한 정도관리 (Quality Control to Improve Reliability of Automatic Water Quality Data)

  • 임병진;홍은영;김현욱
    • 생태와환경
    • /
    • 제43권2호
    • /
    • pp.338-344
    • /
    • 2010
  • 상수원 및 수계의 수질관리 업무를 효율적이고 능동적으로 수행하고, 수질오염사고 발생시 신속한 대응조치를 할 수 있는 조기경보체계 구축을 위하여 주요 상수원 및 하천 등에 수질자동측정망을 설치하여 운영하고 있다. 수온, pH, EC, DO, TOC 항목에 대한 정도평가를 실시하여, 수질자동 측정 자료에 대한 정확도를 확보하여 신뢰도를 제고하고자 하였다. 수질자동측정기기와 수동측정기기에 대한 측정값을 비교한 결과, 대체로 일반항목(수온, pH, EC, DO) 및 TOC의 상대정확도가 20% 이내의 목표를 만족하였다. 그러나 수질자동측정소의 저류수조의 측정기기(내부)와 채수지점의 측정기기(외부)의 측정값 차이를 분석한 결과, 채수거리가 먼 측정소의 DO에 대한 내부-외부의 상대정확도는 목표값을 다소 벗어나는 것으로 나타났다. 채수관로에 조류 및 미생물 부착에 의한 오염이 원인으로 판단되어 역세척하여 측정한 결과, 측정된 DO 농도는 최대 53%까지 상승하는 효과를 나타냈다. 따라서 채수관로 관리가 수질자동측정 자료의 신뢰성을 확보하는데 중요함을 알 수 있었다.

수변구역 산림의 수질정화기능 증진 (II) -­문제점과 대책을 중심으로­- (Enhancement of Water Purification Functions of Watershed Basin (II) -­With a Special Reference to the Point at Issue and Counterplans­-)

  • 박재현
    • 한국환경복원기술학회지
    • /
    • 제5권3호
    • /
    • pp.58-65
    • /
    • 2002
  • This study synthesizes previous research accomplishments with analysis of problems and counterplan for the riparian forest zone management and ongoing research strategy is suggested. If a part of budgets for water use allotments is supported for forest watershed owner, this policy for the forest owner could encourage the forest management of watershed. Integrated riparian forest management guideline in city and county needs to be established for the implementation of government guidelines. Base on the guideline, working plans of city and county could be evaluated. Public Forest Tending Work for stream water quality and quantity conservation should be enlarged for forest watershed and forest area management in five big river watersheds. Forest watershed should be managed with a connected system for a pollutant reduction strategy in urban and industrial areas.

국내 먹는샘물의 수질특성비교 (Comparison of water quality of domestic natural mineral water)

  • 두용균;김준환;김창수;장덕
    • 환경위생공학
    • /
    • 제15권1호
    • /
    • pp.88-94
    • /
    • 2000
  • The purpose of this study was to analyze and compare the contents of minerals and ionic components in domestic commercial natural mineral waters, and to investigate the relationship between water quality and characteristics of suspended and rocks there of its source. All mineral waters tested in this study met the korean mineral water quality guideline, although chemical components varied widely depending upon the geological characteristics and degree of urbanization of the source area or physical water treatment method. The water quality of commercial bottled water was different from that of source water, especially in cationic components, and showed a tendency to become worse with time elapsed. The water quality on the bottle was also different from the measured quality.

  • PDF

수질제어를 통한 관 내부 부식방지 기술의 정수처리공정 적용방안 (Approaches to Internal Corrosion Control Technologies by Controlling Water Quality in Water Treatment Systems)

  • 서대근;왕창근
    • 상하수도학회지
    • /
    • 제20권4호
    • /
    • pp.509-518
    • /
    • 2006
  • Although final water of domestic water treatment plants almost contains highly corrosive characteristics, the countermeasures for eliminating internal corrosion of pipeline system have not been conducted yet by controlling water quality in plants. The technologies of internal corrosion control are to control water quality parameters(pH, Alkalinity, and Calcium Hardness etc.) and to use corrosion inhibitor. Under the conditions of domestic water treatment, first of all, the technologies of adjusting water quality parameters has to be considered. Otherwise, The technology of using corrosion inhibitor is favorably thought to be applied with the technology of adjusting water quality parameters in accordance with the result of availability for water treatment process. Since the technology of adjusting water quality parameter influences on other water treatment processes, the guideline of water quality management to be apt for water quality characteristic is required to be estabilished. While the selection of proper chemicals and technologies is dependent upon the raw water characteristics and water treatment process, typically, the technology of $Ca(OH)_2$ & $CO_2$ additions is considered more effective than other technologies in order to adjust pH and Alkalinity, increase $Ca^{2+}$ and form $CaCO_3$ film

합병정화조 기술현황 및 전망 (Current Condition and Prospect of On-Site Domestic Wastewater Treatment Technologies)

  • 임연택
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 제6회 하계 Workshop (98 한국막학회, 국립환경연구원 국제 Workshop, 수자원 보전과 막분리 공정)
    • /
    • pp.95-112
    • /
    • 1998
  • Water quality in the public water course has been polluted more seriously than ever before due to the increase of the number and aremount of pollution sources such as domestic and industrial wastewater. For water quality conservation, the Korean government has been trying to construct sewage treatment facilities continually, of which treatment capacity reached to 11,452,400m$^{3}$/day in 1996. Night soil treatment facilites of m nationwide have the treatment capacity of 24,038m$^{3}$/day. But water quality has not been improved because the sewer systems were insufficient and the treatment efficiencies of sewage were not high, enough. For renovation of water quality, miscellaneous domestic wastewater must be treated because 27g BOD/day out of total 40g BOD/person-day come from miscellaneous wastewater, comparing to 13g BOD/day from night soil. However, sole treatment purifier treat only night soil from the flushing toilet. Therefore, it may be desirable to treat the miscellaneous domestic wastewater and the night soil from flushing toilet together by joint treatment purifier system as on-site domestic wastewater treatment technology. In Korea, the joint treatment purifier system, introduced in 1997, have the benefit as follows; i) good water poiluion control effect, ii ) good effect on river water flow, iii) water pollution control with sewage treatment facility, and iv) rapid pollution control effect, etc. In order to achieve a good effect as stated before, i ) strengthening effluent guideline including BOD, nitrogen and phosphorus, ii ) specializing operation to maintain high performance, and iii) supporting its construction and maintenance costs by the governmental level may be necessary: In addition, automation system of joint treatment purifier, technology for its package and compactness, and a new bio-media bio-filter with higher capacity should be further developed in agreement with a more stringent effluent guideline.

  • PDF

생태수질기준설정을 위한 대상물질의 생태위해성 평가 (Ecological Risk Assessment of Chemicals of Concern for Initiation of Ecorisk-based Water Quality Standards in Korea)

  • 안윤주;남선화;김용화
    • 한국물환경학회지
    • /
    • 제24권5호
    • /
    • pp.592-597
    • /
    • 2008
  • Current water quality standard (WQS) in Korea is based on the protection of human health, not considering the protection of aquatic organisms. Most of chemicals can be toxic to ecological biota as well as human. Health of aquatic biota is closely related to the human health via food chain, therefore ecological risk based-WQS needs to be developed to protect the aquatic ecosystem. In this study, we selected the 31 chemicals in the Project entitled 'Development of integrated methodology for evaluation of water environment'. The methodology for calculating water quality criteria was derived from the Australian and New Zealand processes for deriving guideline trigger value for aquatic ecosystem. The available ecotoxicity data were collected from US EPA's ECOTOXicology Database (ECOTOX), TOX-2000 Database, European Chemicals Bureau (ECB)'s International Uniform Chemical Information Database (IUCLID) and Environmental Protection Agency (US EPA)'s report 'Ambient Water Quality Criteria (AWQC)'. The aquatic toxicity data for the Korean species were selected for risk assessment to reflect the Korean water environment. The monitoring values were calculated from the water quality monitoring data four main Korean rivers. We suggested the order of priorities of chemicals based on ecological risk assessment. We expect that these results can be useful information for establishing the WQS for the protection of aquatic ecosystem.