• Title/Summary/Keyword: Water pipe supply

Search Result 265, Processing Time 0.019 seconds

The Component Analysis of Foreign Substance Occurred in Water Distribution Networks (상수관망에서 발생하는 이물질의 성분분석)

  • Choi, Min-Ah;Kim, Do-Hwan;Bae, Chul-Ho;Lee, Doojin;Choi, Doo Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.9
    • /
    • pp.614-623
    • /
    • 2014
  • Customers water quality complaints by foreign substance in local water service can be able to call the main cause bring the distrust for tap water and inhibiting the rate of drinking water. In this study, foreign substances were collected in the target region. Foreign objects were subjected to qualitative and quantitative analysis of compounds and elements components to reveal the cause of detection. Also, resolve the complaints by foreign substance and improve the reliability for tap water providing high quality water supply scheme. Collected substances at the water quality complaint area were included in inorganic compounds due to internal corrosion and aging pipeline, as well as organic compounds containing a large amount of carbon (C) and oxygen (O) component. To decide and reduce for foreign substance, objective assessment of pipe condition in target area was required.

Risk analysis of red water and turbid water based on seasonal water usage (계절별 수도사용량에 따른 적수 및 탁수발생 위험도 분석)

  • Han, Jin Woo;Lee, Sang Mok;Kwon, Hyuk Jae
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.7
    • /
    • pp.451-460
    • /
    • 2023
  • In this study, the risk of red water and turbid water occurrence was analyzed by classifying it into detachment risk and deposition risk. First, risk factors for red water and turbid water were determined, and hydraulic analysis was conducted considering seasonal water consumption. The applied area was Cheongju City, and the risk analysis was conducted across 13 areas, and the areas with high deposition risk and high detachment risk were selected. The high risk of both detachment and deposition can be judged as an area with a very high probability of causing water quality problems. The areas with the highest deposition risk and detachment risk are the old towns of Nae deok1-dong and Yul1yang-dong, which are the oldest areas in Cheongju City with an age of more than 30 service years of pipe installation. By analyzing the risk of deposition and detachment, it will be possible to strengthen the maintenance function of the water supply network to provide the safe water to citizens and increase their confidence for tap water.

Development of 1MW Organic Rankine Cycle System for Industrial Waste Heat Recovery Put English Title Here (산업배열회수용 1MW급 유기랭킨 사이클 시스템 개발)

  • Cho, H.C.;Park, H.S.;Lee, Y.K.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.776-781
    • /
    • 2001
  • To enhance thermal efficiency of thermal facility through recovery of low and medium temperature waste heat, 1MW organic Rankine cycle system was designed and developed. The exhaust gases of $175^{\circ}C$ at two 100MW power plants in pohang steel works were selected as the representative of low and medium temperature waste heat in industrial process for the heat source of the organic Rankine cycle system. HCFC-123, a kind of harmless refrigerant, was chosen as the working fluid for Rankine cycle. The organic Rankine cycle system with selected exhaust gases and working fluid was designed and constructed. From the operation, it was confirmed that the organic Rankine cycle system is available for low and medium temperature waste heat recovery in industrial process. The optimum operating manuals, such as heat-up of hot water, turbine start-up, and the process of electric power generation, were derived. However, electric power generated was not 1MW as designed but only 670kW. It is due to deficiency of pump capacity for supply of HCFC-123. So it is necessary to increase the pump capacity or to decrease the pressure loss in pipe for more improved HCFC-123 supply.

  • PDF

Air Layer Effect on the Performance Improvement of a Cross-Flow Hydro Turbine

  • Choi, Young-Do;Shin, Byeong-Rog;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.37-43
    • /
    • 2010
  • The purpose of this study is not only to investigate the effects of air layer in the turbine chamber on the performance and internal flow of the cross-flow turbine, but also to suggest a newly developed air supply method. Field test is performed in order to measure the output power of the turbine by a new air supply method. CFD analysis on the performance and internal flow of the turbine is conducted by an unsteady state calculation using a two-phase flow model in order to embody the air layer effect on the turbine performance effectively. The result shows that air layer effect on the performance of the turbine is considerable. The air layer located in the turbine runner passage plays the role of preventing a shock loss at the runner axis and suppressing a recirculation flow in the runner. The location of air suction hole on the chamber wall is very important factor for the performance improvement. Moreover, the ratio between air from suction pipe and water from turbine inlet is also significant factor of the turbine performance.

Analyses of Seasonal Water Quality Pollution for Side Planning (수변계획을 위한 계절별 수질오염 분석)

  • Lee, Yang-Kyoo;Han, Jung-Geun;Hong, Chang-Sun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.3
    • /
    • pp.347-355
    • /
    • 2006
  • Anyang Stream including its main branch is the biggest branch stream of Han River in Korea. The geological and geomorphological characteristics were investigated to the affected area of Anyang Stream, in which rainfall characteristic was analyzed. The water quality surveyed that the analysis of water pollution used to biotic index and biological water pollution. The rainfall pattern in this area was like to that of typical Korea, but the rate of trigger and runoff during summer season(June~August) is more higher than mean of Korea. Before 2003, a dried stream is severe status, which was due to abundant runoff, but this status are improved. After 1997, water quality of stream is recovering status such as water pollution of stream steeply decreased. Especially after 2003, this trend is more quickly improved. Although, owing to the increasing of a T-N and SS at upstream wastewater were due to bad collection of industrial factories, livestock's and mans living, the water quality worsted at upstream. Water quality in total section of main stream was severely contaminated that water-quality limit is 5 with polysaprobic by water self-purification. That of main branch was 1~3limits with ${\alpha}$- and ${\beta}$-mesosaprobic in Anyang city area, But water quality in all area about another branch of Anyang stream except Anyang city area was almost under of 3 grades. Though trying of Anyang city for recover movement(completion of 2nd Sewage Treatment Plant and Water supply pipe system) on Anyang stream, water pollution states of upper branch in Anyang stream was not better than its of 2002 because it may be difference of control area on other cities.

Efficiency evaluation of water leakage management methods in local small and medium cities (지방중소도시의 누수관리방법에 대한 효율성 평가)

  • Hwang, Jinsoo;Choi, Taeho;Kim, Kibum;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.2
    • /
    • pp.121-133
    • /
    • 2021
  • This study set up the estimates of leakage management efficiency evaluation and leakage management goal that could be used in local water distribution networks efficiency business and modernization business. The data were analyzed using data envelopment analysis and multiple regression analysis. To this end, with leakage management input indices concerning leakage reduction activities (e.g., aged pipe replacement, water meter replacement, leakage restoration, and leakage detection) and leakage management calculation indices (e.g., the increase of revenue water ratio and the reduction of leakage ratio), the data on 22 K-water consignment local water supply systems were analyzed for the years from 2004 through 2018. Using the results of efficiency analysis by data envelopment analysis, the other DMUs (Decision Making Unit) benchmarked the DMU with the highest efficiency to maximize the leakage management efficiency for all DMUs. Through this, leakage management goal estimates were drawn with the input indices of four leakage reduction activities and calculation indices of the increase of revenue water ratio and the reduction of leakage ratio by multiple regression analysis for each group based on the revenue water ratio and leakage ratio. The correlation coefficients of the leakage management goal estimate for the criteria for the revenue water ratio amounted to 0.553 and 0.771. The correlation coefficients of the leakage management goal estimate for the criteria for leakage ratio were 0.397 and 0.865. Accordingly, we estimated the quantity and priority of four leakage reduction activities for the target leakage ratio and revenue water ratio.

Efficiency Evaluation of Genetic Algorithm Considering Building Block Hypothesis for Water Pipe Optimal Design Problems (상수관로 최적설계 문제에 있어 빌딩블록가설을 고려한 유전 알고리즘의 효율성 평가)

  • Lim, Seung Hyun;Lee, Chan Wook;Hong, Sung Jin;Yoo, Do Guen
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.294-302
    • /
    • 2020
  • In a genetic algorithm, computer simulations are performed based on the natural evolution process of life, such as selection, crossover, and mutation. The genetic algorithm searches the approximate optimal solution by the parallel arrangement of Schema, which has a short definition length, low order, and high adaptability. This study examined the possibility of improving the efficiency of the optimal solution by considering the characteristics of the building block hypothesis, which are one of the key operating principles of a genetic algorithm. This study evaluated the efficiency of the optimization results according to the gene sequence for the implementation in solving problems. The optimal design problem of the water pipe was selected, and the genetic arrangement order reflected the engineering specificity by dividing into the existing, the network topology-based, and the flowrate-based arrangement. The optimization results with a flowrate-based arrangement were, on average, approximately 2-3% better than the other batches. This means that to increase the efficiency of the actual engineering optimization problem, a methodology that utilizes clear prior knowledge (such as hydraulic properties) to prevent such excellent solution characteristics from disappearing is essential. The proposed method will be considered as a tool to improve the efficiency of large-scale water supply network optimization in the future.

Development of Technology to Secure Refuge Space by Using Existing Restroom (화장실을 이용한 층별 피난공간 확보 기술개발)

  • Kim, Ji-Seok;Shin, Hyun-Joon;Kim, Jung-Yup;Park, Byoung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.24-30
    • /
    • 2015
  • The fire on a high-rise building would possibly cause fatalities because of ineffective egress due to extended evacuation distance in huge building structure, coupled with dense population, thus requiring secured optimal evacuation method and space. The restroom located in the living space is considered to be useful refuge space which is built with wet pipe and noncombustible materials. This study aimed to develop a system that would make use of the existing restroom as a fire refuge space. Ventilation duct were installed to discharge odor during normal conditions. We could serve the air supply duct to also raise the air pressure in the restroom so as to prevent the toxic gas from gapping around the restroom. The nozzle for the water screen would be installed in restroom door facing the living room to form the water screen which would protect the door. This study is intended to replace the existing refuge space with the restroom in such a way as described above.

A Study on the Characteristics of Local Corrosion for Gas Absorption Refrigeration and Hot Water Systems in LiBr-$H_2O$ Working Fluids (LiBr작동유체 중에서 가스흡수식 냉온수기의 국부부식 특성에 관한 연구)

  • Uh- Joh Lim;Ki-Cheol Jeong;Byoung-Du Yun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.714-720
    • /
    • 2003
  • Due to the electric power shortage in summer season and regulation of freon refrigerant, the application of gas absorption refrigeration and hot water systems are considerably increasing trend. But, this system consists of condenser, heat exchanger, supply pipe and radiator etc. which are easily corroded by acidity and dissolved oxygen and gases. In result, this system occurs scale attachment and corrosion damage like pitting and crevice corrosion. In this study, electrochemical polarization test of heat exchanger tubing material (copper, aluminium brass, 30% cupronickel(30% Cu-Ni)) was carried out in 60% lithium bromide solution at $95^{\circ}C$. As a result of polarization test, corrosion behavior by impressed potential and local corrosion. such as galvanic corrosion, pitting corrosion behavior, of tubing materials was investigated. The main results obtained are as follows: (1) The effect of pitting and crevice corrosion control of 30% cupronickel in 60% LiBr solution at $95^{\circ}C$ is very excellent. (2) Dissimilar metal corrosion of 30% cupronickel coupling to aluminium bronze is the most sensitive. (3) Current density behavior of tube materials by impressed potential is high in order of copper > aluminium brass > 30% cupronickel.

Development of Hybrid Device for Photovoltaic Power Generation and Heating (복합식 태양광 발전 및 난방장치 개발)

  • Lee, Dong Il;Baek, Seung Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.11
    • /
    • pp.907-914
    • /
    • 2014
  • The objective of this study was to increase the generating efficiency of concentrated photovoltaics (CPV) by using hybrid solar tracking. Further, the proposed system was demonstrated to have the ability to extract thermal energy from a concentrated photovoltaic system by using thermal absorbers containing heat pipe, which could then be used for a heating system or hot-water supply. The average electrical efficiency was 16 during the day, and the average thermal efficiency was 62. Therefore, this system demonstrated a total efficiency (electrical thermal) of 78. All the processes, i.e., tracking of the sun, calculation of the sun's position, reinstatement of the heating device toward the east for tracking on the next day, and system shutdown, were programmed using Simulink. A parametric analysis of the heat pipe, concentration ratio, and inlet velocity was also performed in terms of the operating temperature of the CPV and the outlet temperature. The simulation and experimental results for the thermal absorber were found to be in good agreement.