• Title/Summary/Keyword: Water intake station

Search Result 75, Processing Time 0.036 seconds

A Buoyant Combined Solar-Wave Power Generation and Its Application for Emergency Power Supply of Nuclear Power Plant (부유식 태양광-파력 복합발전 개념 및 원자력발전소 비상전원을 위한 응용)

  • Cha, Kyung-Ho;Kim, Jung-Taek
    • New & Renewable Energy
    • /
    • v.7 no.4
    • /
    • pp.37-41
    • /
    • 2011
  • This paper presents a Combined solar-wave Power Generation (CPG) concept that the CPG unit is maintained as buoyant at the level of sea water and it is also supported by a submerged tunnel, with the aim of supplying emergency electric power during the station blackout events of nuclear power plants. The CPG concept has been motivated from the 2011 Fukushima-Daiichi Accidents due to the loss of both offsite AC power and emergency diesel power caused by natural hazards such as earthquake and tsunami. The CPG is conceptualized by applying different types and different sites for emergency power generation, in order to reduce common cause failures of emergency power suppliers due to natural hazards. Thus, the CPG can provide a new mean for supplying emergency electric power during station blackout events of nuclear power plants. For this application, the CPG requirements are described with a typical configuration at the ocean side of a submerged tunnel.

SEASONAL VARIATIONS OF CHLORIDE, CALCIUM AND MAGNESIUM ION CONCENTRATIONS IN NAGDONG RIVER WATER AT MUL GEUM INTAKE STATION OF BUSAN CITY WATER FROM MARCH 1974 TO MARCH 1975 (낙동강 물금구취수장 상수도원수의 염화이온 칼슘 마그네슘 농도의 연간변동에 대하여(1974년-1975년))

  • WON Jong Hun;YANG Han Serb
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.11 no.2
    • /
    • pp.103-109
    • /
    • 1978
  • The contents of chloride ion, calcium and magnesium in Nagdong River water were determined at Mul Geum where the intake station for Busan city water is located. Samples were taken in spring and neap tides of every month from March 1914 to March 1975. The range and mean values of the chloride ion and total hardness were 5.12-39.4ppm, 11.9ppm; 27.8-70.8ppm, 49.5ppm respectively from March 1974 to January 1975. The highest values were found in the period of the widest tidal range of a year, from February 9 to March 9 in 1975, such as tile ranges and means of chloride ion and total hardness were 10.8-876 ppm, 89.8ppm : 48.0-407ppm, 89.9ppm. On several days of this period those concentrations were over the criteria of drinking water, 150 ppm in chloride and 300ppm in total hardness. Chloride ion concentration was increased with increasing of water level of the Nagdong River at Mul Geum. The patterns of the variations of tide level were similar to that of water level with delay of 2.5 hours in spring tides and 3 hours in neap tides.

  • PDF

Development of Smart Remote Terminal Unit for Water Treatment SCADA System (상하수도 원격감시제어 시스템 구현을 위한 스마트 RTU의 개발 및 적용)

  • Jang, Sang-Bok;Lee, Ho-Hyun;Hong, Sung-Taek;Chun, Myung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.24-30
    • /
    • 2014
  • In this paper, a new remote terminal unit(hereafter RTU) is proposed to manage a wide range of applications and a variety of sensors (eg, pressure, water quality, temperature and humidity sensors, the amount of pollutants, $CO_2$, etc.) to monitor and control the facility such as water treatment plant, intake and effluent pumping station, water tank and distribution network. Fault status of local sensor devices and network are alerted by using the embedded fault handling capabilities of the RTU in the system and also sent to the fault handling server, by which fault can be easily monitored to users. The developed system was applied to one of K-water branch offices in Geoje city and improved its reliability and stability for controlling and monitoring water facility.

SEASONAL VARIATIONS OF THE CONTENTS OF INORGANIC CONSERVATIVE CONSTITUENTS OF NAGDONG RIVER WATER AT MULGEUM INTAKE STATION OF BUSAN CITY WATER FROM JANUARY 1979 TO APRIL 1980 (낙동강 물금취수장 상수도 원수의 무기보존성분량의 연간변동에 대하여(1979년 1월-1980년 4월))

  • LEE Bae Jung;WON Jung Hun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.13 no.3
    • /
    • pp.103-108
    • /
    • 1980
  • The contents of inorganic conservative constituents in Nagdong River water were determined at Mulgeum where the intake station for Busan city water is located. Samples were taken at intervals of one hour from 7 a.m. to 7 p.m. at spring and neap tides of every month from January 1979 to April 1980. Annual ranges and means of the chemical constituents were as follows: electrical conductivity $99-912\mu\mho/cm,\;200\mu\mho/cm;$ chlorides 6.0-256 ppm, 17.2 ppm; sulfates 4.1-37.9 ppm, 23.5 ppm; calcium 4.2-28 ppm, 13 ppm; magnesium 2.2-23 ppm, 5.6 ppm; sodium 5,0-126 ppm, 14 ppm; and potassium 1.2-10.8 ppm, 2.6 ppm respectively. At several times in this period, the concentrations of chloride ion exceeded 150 ppm that is the criteria for drinking water. The chloride ion concentration was higher at spring tides than that at neap tides and the contents of inorganic conservative constituents were higher in winter than those in summer. The chloride ion concentration showed the highest value at Mulgeum about 4 hors after the high water in Busan harbour.

  • PDF

Biofouling and Microbial Induced Corrosion -A Case Study

  • Mohammed, R.A.;Helal, A.M.;Sabah, N.
    • Corrosion Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.27-34
    • /
    • 2008
  • In industrial and fluid handling systems, frequently the protective film forming materials suffer from severe corrosion due to microbial effects. As an example, various micro-organisms, including bacteria, exist in seawater normally fed to power and desalination plants. Unless seawater intakes are properly disinfected to control these microbial organisms, biological fouling and microbial induced corrosion (MIC) will be developed. This problem could destroy metallic alloys used for plant construction. Seawater intakes of cogeneration plants are usually disinfected by chlorine gas or sodium hypochlorite solution. The dose of disinfectant is designed according to the level of contamination of the open seawater in the vicinity of the plant intake. Higher temperature levels, lower pH, reduced flow velocity and oxidation potential play an important role in the enhancement of microbial induced corrosion and bio-fouling. This paper describes, in brief, the different types of bacteria, mechanisms of microbiological induced corrosion, susceptibility of different metal alloys to MIC and possible solutions for mitigating this problem in industry. A case study is presented for the power plant steam condenser at Al-Taweelah B-station in Abu Dhabi. The study demonstrates resistance of Titanium tubes to MIC.

Two-Dimensional River Flow Analysis Modeling By Finite Element Method (유한요소법에 의한 2차원 하천 흐름 모형의 개발)

  • Han, Kun-Yeun;Kim, Sang-Ho;Kim, Byung-Hyun;Choi, Seung-Yong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.425-429
    • /
    • 2006
  • The understanding and prediction of the behavior of flow in open channels are important to the solution of a wide variety of practical flow problems in water resources engineering. Recently, frequent drought has increased the necessity of an effective water resources control and management of river flows for reserving instream flow. The objective of this study is to develop an efficient and accurate finite element model based on Streamline Upwind/Petrov-Galerkin(SU/PG) scheme for analyzing and predicting two dimensional flow features in complex natural rivers. Several tests were performed in developed all elements(4-Node, 6-Node, 8-Node elements) for the purpose of validation and verification of the developed model. The U-shaped channel of flow and natural river of flow were performed for tests. The results were compared with these of laboratory experiments and RMA-2 model. Such results showed that solutions of high order elements were better accurate and improved than those of linear elements. Also, the suggested model displayed reasonable velocity distribution compare to RMA-2 model in meandering domain for application of natural river flow. Accordingly, the developed finite element model is feasible and produces reliable results for simulation of two dimensional natural river flow. Also, One contribution of this study is to present that results can lead to significant gain in analyzing the accurate flow behavior associated with hydraulic structure such as weir and water intake station and flow of chute and pool.

  • PDF

Enhanced oxidative stability of meat by including tannin-rich leaves of woody plants in goat diet

  • Garcia, Elisa Mariana;Lopez, Agustin;Zimerman, Maria;Hernandez, Olegario;Arroquy, Jose Ignacio;Nazareno, Monica Azucena
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.9
    • /
    • pp.1439-1447
    • /
    • 2019
  • Objective: The aim of this study was to evaluate the effect of dietary incorporation of tanninrich woody species on meat oxidative stability, carcass traits and meat quality in goats. Methods: Two tannin-rich species were tested using a three-treatments feeding trial, where treatments consisted of: Larrea divaricata and Acacia aroma both at 12.5% in dry matter basis of the diet and a control diet (alfalfa hay). All feeding diets were iso-protein and iso-energy. Carcass conformation, carcass compactness, carcass fatness and subcutaneous fat deposition were evaluated. Intake, liveweigh, Longissimus thoracis et lumborum muscles of goats were analyzed in order to evaluate quality parameters such as pH value, instrumental color evaluation, water holding capacity, total phenolic content, antioxidant activity, meat oxidative stability and fatty acid profiles in meat. Results: Feed intake, liveweight gain, carcass, and meat traits did not differ among treatments. Changes in meat lipid profile among treatments were observed for oleic and elaidic acid contents. Meat total phenolic content and antioxidant activity did not differ among treatments; although, meat oxidative status after storage at room temperature, as well as under refrigerated and frozen conditions were different between control and both supplemented groups. Conclusion: The inclusion of Acacia aroma and Larrea divaricata leaves in goat diet enhanced meat oxidative stability. Modulation of the ruminal biohydrogenation of fatty acids produced by condensed tannins of these plant species need to be further investigated.

Development of Pump/Motor Selection Program for Optimized Pump Decision of the Regional Water Supply Facilities (광역상수도용 펌프의 최적결정을 위한 펌프/모터 선정 프로그램 개발)

  • Roh, Hyung-Woon;Kim, Jae-Soo;Park, Gil-Moon;Suh, Sang-Ho;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.4 s.13
    • /
    • pp.22-27
    • /
    • 2001
  • The pump/motor selection program for optimized selection of regional water supply facilities was developed based on a flowchart compiled from basic operational data, total head requirement, initial pump/motor specification selection etc. This program was developed in Visual Basic. The program accepts, as in the flowchart, operational requirements of pumps and other system requirements, and calculates specific speed based on flow rate, total head and rotational speed. Then the calculated specific speed is used to select pump types and speed prior to determining likelihood of cavitation occurring at the calculated NPSH. Power requirement is then calculated for safe operation of pump to assist final pump selection. Test results of the program match very closely to the design values of Paldang intake pump station(3rd stage) proving that the program can be used as an effective and practical aid for designing new regional water supply systems.

  • PDF

Development of Pump/Motor Selection Program for Optimized Pump Decision of the Regional Water Supply Facilities (광역상수도용 펌프의 최적결정을 위한 펌프/모터 선정 프로그램 개발)

  • Roh, Hyung-Woon;Kim, Jae-Soo;Park, Gil-Moon;Suh, Sang-Ho;Lee, Young-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.171-176
    • /
    • 2001
  • The Pump/Motor Selection Program for optimized selection of regional water supply facilities was developed based on a flowchart compiled from basic operational data, total head requirement, initial pump/motor specification selection etc.. This program was developed in Visual Basic. The program accepts, as in the flowchart, operational requirements of pumps and other system requirements and calculates specific speed based on flow rate, total head and na Then the calculated specific speed is used to select pump types and rpm Prior to determining likelihood of cavitation occurring at the calculated NPSH. Power requirement is then calculated for safe operation of pump to assist final pump selection. Test results of the program matches very closely to the design values of Paldang intake pump station(3rd stage) proving that the program can be used as an effective and practical aid for designing new regional water supply systems.

  • PDF

Assessment of Selective Withdrawal Facility in the Imha Reservoir Using CE-QUAL-W2 Model (CE-QUAL-W2 모델을 이용한 임하호 선택배제시설의 효과분석)

  • Lee, Sanguk;Kim, Jeongkon;Noh, Joonwoo;Ko, Ick Hwan
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.228-235
    • /
    • 2007
  • For efficient turbid water withdrawal in the Imha reservoir, a selective withdrawal facility was recently installed and operated during summer season of year 2006. In this research, CE-QUAL-W2 model was utilized to assess the efficiency of the selective withdrawal facility, in comparison with the original surface withdrawal, on turbid water management. Model calibration was carried out using data observed at four automatic monitoring stations in the reservoir. It was found that the model appropriately simulated, with the RMSE less than 5.2 NTU, the observed vertical and horizontal distributions of water temperature and turbidity as well as the location of maximum turbid water at each monitoring station. The analysis results showed that selective withdrawal is more effective in removing high turbid water than surface withdrawal as selective withdrawal contributed to reducing $35Mm^3$ of high turbidity water (> 100 NTU) in the reservoir by increasing outflows of high turbid water. Therefore, effective management of turbid water in the reservoir can be achieved by changing locations of intake depending on turbid water distribution conditions. The results of this study will provide some basic information for establishing better operation strategies to cope with turbid water problems.