• Title/Summary/Keyword: Water expansion

Search Result 1,060, Processing Time 0.03 seconds

A Study on the Application of the Electric Arc Furnace Slag Aggregate in Concrete (콘크리트용 골재로서 전기로슬래그의 적용성에 대한 연구)

  • 문한영;유정훈
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.3
    • /
    • pp.101-111
    • /
    • 1999
  • Compared with the BF slag, the EAF slag has expansion due to the reaction with water and free CaO. Therefore it is specified in Concrete Specification that the FAP slag aggregated must not be used in concrete. Because of this reason it is unusual to use the EAF slag aggregate in concrete. The EAF slag aggregate treated with accelerated and water aging was comparatively satisfied with fundamental properties, which are specific gravity, unit weight, abrasion and immersion expansion ratio, as concrete aggregate. Therefore when we measured the compressive strength till 28 days, we found that the mortar and concrete replacing the natural aggregate with the EAF slag aggregate by 4 steps had better results than the concrete using the natural aggregate in a view of the compressive strength. But at 91 days, concrete using the EAF slag aggregate had no difference with it using the natural aggregate.

The Performance of a Heat Pump with a Variation of Expansion Valve at Various Charging Conditions (냉매 충전량과 팽창장치 변화에 따른 열펌프 시스템의 성능특성에 관한 연구)

  • 최종민;김용찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.661-666
    • /
    • 2003
  • Constant area expansion devices such as capillary tubes, short tube orifices are being gradually replaced with electronic expansion valves (EEVs) because of increasing focus on comfort and energy conservation. In this study, the performance of a water-to-water heat pump as a function of refrigerant charge is investigated in steady state, cooling mode operation with expansion devices of a capillary tube and an EEV. The performance of the capillary tube system varies drastically according to the change of refrigerant charge amount and inlet temperature of the secondary fluid in the condenser. Cooling capacity and COP of the EEV system show little dependence on the refrigerant charge, while those are strongly dependent on the secondary fluid temperature at the condenser inlet. In general, for a wide range of operating conditions the EEV system shows much higher performance as compared with the capillary tube system. The performance of the EEV system can be optimized by adjusting EEV opening to maintain a constant superheat at all test conditions.

Autogenous Expansion Models of Dam Concrete containing MgO (MgO를 혼입한 댐 콘크리트의 자기팽창 모델)

  • Choi, Seul-Woo;Oh, Sang-Hyuk;Lee, Kwang-Myong;Jang, Bong-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.275-276
    • /
    • 2010
  • In this study, using experimental results on the autogenous expansion of concrete containing MgO, autogenous expansion model which considers water-binder ratio, amount of MgO and curing temperature was suggested. The results predicted by autogenous expansion model agreed well with experiment results.

  • PDF

Decision of Backwashing frequency and method on the GAC adsorber (입상활성탄 흡착지 운영에서 역세척 주기와 팽창률의 영향 평가)

  • Chae, Seon-Ha;Cho, Chang-Hyun;Lee, Hee-Dae;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.6
    • /
    • pp.753-762
    • /
    • 2010
  • The objective of this study was to evaluate the backwashing frequency and method on the Granular Activated Carbon (GAC) in G WTP. A backwashing period was determined as 50 days and 60 days, respectively. Prior to Backwashing by head loss build, biomass concentration in effluent as constant and DO concentration was maintained more than 11.5 mg/L in GAC bed. Peak turbidity of backwashing water was 73.6~303 NTU. Mean turbidity of backwashing water at initial 9 minute of backwash operation was 50.7~82.8 NTU. After 30 minute backwashing operation, final turbidity reaches approximately 10 NTU. The frequency of backwashing and turbidity of backwashing water overtime were evaluated. At 20days of backwashing frequency, the peak turbidity was 73 NTU and 42 NTU respectively when 10% and 25% of expansion of GAC were applied. At 14 minute of backwashing time, it was observed that turbidity of 10% expansion of GAC was higher than that of 20% expansion.

Effect of Water-Soluble Polymer on the Properties of High Strength Hardened Cement Paste (고강도 시멘트 경화체의 특성에 미치는 수용성 폴리머의 영향)

  • 김정환;최상흘;한기성
    • Journal of the Korean Ceramic Society
    • /
    • v.26 no.5
    • /
    • pp.698-704
    • /
    • 1989
  • Basic investigation for the flexural strength and water stability of hardened cement pastes using ordinary portland cement with water-soluble polyer (hydroxypropyl methyl cellulose ; HPMC) was carried out with 0.2 of water cement ratio. For molding of the specimen, the paste was mixed by twin roll mill. According to increase in the content of HPMC, the setting time of cement paste was delayed and the flexural strength was increased. The maximum flexural strength of hardened cement paste with 5.0wt% of HPMC was about 330 kg/$\textrm{cm}^2$. The expansion of the hardened cement paste immersed in water was increased with the content of water soluble polymer(HPMC). Consequently, the strength and the water stability of the hardened cement pastes were remarkably reduced by the expansion of them.

  • PDF

Volume Expansion of Ionic Liquids in the Presence of Supercritical Carbon Dioxide (초임계이산화탄소의 존재 하에서 이온성액체의 부피팽창)

  • Lim, Bang-Hyun;Shim, Jae-Jin
    • Clean Technology
    • /
    • v.14 no.4
    • /
    • pp.248-255
    • /
    • 2008
  • The volume expansion of three ionic liquids (ILs) in the presence of supercritical carbon dioxide has been measured at pressures up to 32 MPa and at temperatures from 313.15 to 333.15 K in a high-pressure view cell. The imidazolium-derivative ionic liquids 1-butyl-3-methylimidazolium hexafluorophosphate ([bmim][$PF_6$]), 1-butyl-3-methylimidazolium tetrafluoroborate ([bmim][$BF_4$]), and 1-octyl-3-methylimidazolium tetrafluoroborate ([omim][$BF_4$]) were employed in this research. The effects of pressure, temperature, nature of anion and cation as well as the water content on the volume expansion of ILs by absorbing $CO_2$ were investigated experimentally. The volume expansion was higher for the ILs with longer cationic alkyl group and for the ILs with lower anion polarity. The lower the water content, the lower the temperature, or the higher the pressure, the higher was the expansion of IL phase.

  • PDF

An Experimental Study on the Waterproofing Performance of Expansion Equipment for Underground Structures (지하구조물용 신축이음장치의 방수성능에 관한 실험연구)

  • Lee, Young-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4302-4309
    • /
    • 2012
  • Underground structures without the expansion joint in the settled intervals, the underground structures may suffer from structural crack and the water leakage thereby resulting in the occurance of the efflorescence. In this study, the performance of new expansion joint used in underground structures were verified. The spacing of expansion joint was defined by the finite element analysis. Expansion length, resistance and waterproofing performance of developed expansion joint were confirmed by experiment.

A semi-analytical solution to spherical cavity expansion in unsaturated soils

  • Tang, Jianhua;Wang, Hui;Li, Jingpei
    • Geomechanics and Engineering
    • /
    • v.25 no.4
    • /
    • pp.283-294
    • /
    • 2021
  • This paper presents a rigorous solution for spherical cavity expansion in unsaturated soils under constant suction condition. The hydraulic behavior that describes the saturation-suction relationship is modeled by a void ratio-dependent soil-water characteristic curve, which allows the hydraulic behavior to fully couple with the mechanical behavior that is described by an extended critical state soil model for unsaturated soil through the specific volume. Considering the boundary condition and introducing an auxiliary coordinate, the problem is formulated to a system of first-order differential equations with three principal stress components and suction as basic unknowns, which is solved as an initial value problem. Parameter analyses are conducted to investigate the effects of suction and the overconsolidation ratio on the overall expansion responses, including the pressure-expansion response, the distribution of the stress components around the cavity, and the stress path of the soil during cavity expansion. The results reveal that the expansion pressures and the distribution of the stress components in unsaturated soils are generally higher than those in saturated soils due to the existence of suction.

Numerical Simulation on Dynamic Characteristics of a Water Heater System Driven by a Heat Pump (열펌프 가열식 온수기의 동적특성 해석)

  • 김민성;김민수;백남춘
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.1
    • /
    • pp.10-20
    • /
    • 2002
  • A dynamic model of a water heater system heated by a heat pump was developed. The water heater system was composed of heat pump and hot water reservoirs. Finite volume method (FVM) was applied to describe the heat exchangers. A new constraint on electronic expansion valve (EEV) or thermostatic expansion valve (TXV) that can control superheat after the evaporator was developed. Dynamic performances were evaluated for various sizes of the reservoir. In order to compare those performances, time scale was normalized by time constant representing the characteristics of reservoir size. Time constant was determined from quasi steady-state simulation of the system. From the simulation, the size of the water heater reservoir was found to have a large influence on the transient performance of the sys- tem. Therefore, the optimization of the reservoir size is needed in a design process.

The Impact of Climate Change on the Dynamics of Soil Water and Plant Water Stress (토양수분과 식생 스트레스 동역학에 기후변화가 미치는 영향)

  • Han, Su-Hee;Kim, Sang-Dan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.52-56
    • /
    • 2009
  • In this study a dynamic modeling scheme is presented to derive the probabilistic structure of soil water and plant water stress when subject to stochastic precipitation conditions. The newly developed model has the form of the Fokker-Planck equation, and its applicability as a model for the probabilistic evolution of the soil water and plant water stress is investigated under climate change scenarios. This model is based on the cumulant expansion theory, and has the advantage of providing the probabilistic solution in the form of probability distribution function (PDF), from which one can obtain the ensemble average behavior of the dynamics. The simulation result of soil water confirms that the proposed soil water model can properly reproduce the results obtained from observations, and it also proves that the soil water behaves with consistent cycle based on the precipitation pattern. The plant water stress simulation, also, shows two different PDF patterns according to the precipitation. Moreover, with all the simulation results with climate change scenarios, it can be concluded that the future soil water and plant water stress dynamics will differently behave with different climate change scenarios.

  • PDF