• Title/Summary/Keyword: Water exchange

Search Result 1,492, Processing Time 0.036 seconds

Preparation and Characterization of Heterogeneous Anion Exchange Membrane for Recovery of Sulfate Ion from Waste Water (폐수 중 황산이온 회수를 위한 불균질 음이온교환막의 제조 및 특성)

  • Choi, Kuk-Jong;Choi, Jae-Hwan;Hwang, Eui-Hwan;Rhee, Young-Woo;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.31 no.3
    • /
    • pp.247-254
    • /
    • 2007
  • Heterogeneous anion exchange membranes were prepared by compression molding for the recovery of sulfate ion from waste water. The swelling ratio, transport number, and ion exchange capacity of the heterogeneous anion exchange membranes were increased and their electrical resistances were decreased as the amount of ion exchange resin content in the matrix was raised. The tensile strength of the heterogeneous anion exchange membrane was decreased with increasing the amount of ion exchange resin in the LLDPE. The tensile strength for the LDPE heterogeneous membrane containing 30 wt% anion exchange resin showed the highest value. The water content increased with increasing amount of ion exchange resin in the membrane. Moreover the highest transport number of the membrane was 0.86. The electrical resistance of LDPE matrix membrane with 50 wt% resin showed $46.5{\Omega}{\cdot}cm^2$. Current efficiency of electrodialysis for sulfate ion showed the highest value at the current density of $125 mA/cm^2$ in 0.5 mol/L sulfuric acids solution.

Cooperation plan between South-North Korea in the water environment sector (물환경분야 남북한 협력방안)

  • Kim, Geonha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.1
    • /
    • pp.23-33
    • /
    • 2020
  • With growing expectations for economic cooperation between the two Koreas, there is much interest in participating in the construction of infrastructure in North Korea. In particular, water and sewage infrastructure is the four major social infrastructures in addition to housing, transportation, electricity and telecommunications. North Korea is known to have severe water pollution and ecosystem destruction in major rivers, water pollution and soil pollution in mining areas are serious, and water and sewage infrastructures in cities other than Pyongyang are known to be weak. Preemptive investment in water supply and drainage in North Korea is the foundation for securing the quality of life of the North Korean and is the foundation of public health and industry. It is a leading investment to reduce the cost of unification and is a new growth engine for the water reloded industry. In this study, we proposed a plan to exchange and cooperate in water environment for building water infrastructure of North Korea by examining the data related to water quality, water resources, water disaster, related legal system and human resources exchange situations in North Korea.

Effects of Turbulent Mixing and Void Drift Models on the Predictions of COBRA-IV-I

  • Yoo, Yeon-Jong;Hwang, Dae-Hyun;Nahm, Kee-Yil;Sohn, Dong-Seong
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.284-289
    • /
    • 1996
  • The predictions of the COBRA-IV-I code with the modified turbulent mixing and void drift models have been compared with the diabatic two-phase flow data on equilibrium quality. The turbulent mixing model based on an equal mass exchange of the existing COBRA-IV-I code has been modified to that based on an equal volume exchange between adjacent subchannels, and a void drift model has been newly incorporated in the code. To evaluate the performance of the equal volume exchange turbulent mixing model and the effects of the void drift model, the diabatic steam-water two-phase flow data obtained for the 9-rod bundle test under the typical operating conditions of the boiling water reactor(BWR) conducted by the General Electric (GE) were analyzed by the modified COBRA-IV-I code. The analysis indicates that the equal volume exchange turbulent mixing model with void drift predicts the observed two-phase flow data trends better than the equal mass exchange model, and to predict the correct data trends a more physically based void drift model need to be developed.

  • PDF

Industrial Waters of Taegu City and on the Objection of Iron for Water Softening (大邱市의 工業用水와 鐵의 軟化障害에 關하여)

  • Lee, Dae-Soo;Hong, Soon-Yung
    • Journal of the Korean Chemical Society
    • /
    • v.6 no.2
    • /
    • pp.117-121
    • /
    • 1962
  • The waters throughout Taegu area for 87 points were analysed and according to the analytical data, following unfavorable characteristics for industrial uses were given: (1)Shows strong hardness, (2)Has high ratio of ignition residue to evaporation residue, (3) pH value is over 7, (4) Contains considerable quntities of iron.And then investigated the exchange rate and regeneration level of iron ion using cation exchange resin, Lewatit KS.When the hard water containing 2.2 ppm of iron with 18.4 ppm of calcium and 6.2 ppm of magnesium was passed through the ion exchange resin under $3cc/cm^2/min$ in exhaustant flow rate, exchange rate of iron reached to 42% after 300 hours flow. The exchange efficiency shows abrupt decreasing in initial stage of flow up to 100 hours flow. The exchanger which contains iron was regenerated with 10% sodium hydroxide aqua solution under SV (space velocity) 4. By this method, 57% of iron was eliminated from exchanger while calcium and magnesium are removed as much as 85% and 87% respectively.

  • PDF

Simultaneous Determination of Anions and Cations in Natural Water by Ion-exclusion/Cation-exchange Chromatography with a Weakly Acidic Cation-exchange Resin Column

  • Lee, Kwang-Pill;Choi, Seong-Ho;Park, Yu-Chul;Bae, Zun-Ung;Lee, Mu-Sang;Lee, Sang-Hak;Chang, Hye-Yong;Kwon, Se-Mok;Kazuhiko Tanaka
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.9
    • /
    • pp.1324-1328
    • /
    • 2003
  • The simultaneous determination of anions ($SO_4 ^{2-},\;Cl^-,\;and\;NO_3^-$) and cations ($Na^+,\;NH^{4+},\;K^+,\;Mg^{2+},\;and\;Ca^{2+}$) in natural water obtained by Nakdong River waters system in Korea were performed by ion-exclusion/cationexchange chromatography with conductimetric detection. The stationary phase was a polymethacrylate-based weakly acidic cation-exchange resin column in the $H^+$-form and a weak-acid eluent. When using only a 1.4 mM sulfosalicylic acid/6 mM 18-crown-6 ether as an eluent, good resolution of both anions and cations, minimum time required for the separation, and satisfactory detection sensitivity were obtained in a reasonable time. The method was successfully applied to the simultaneous determination of anions and cations in natural waters.

Study of Development of Selective Removal Adsorption Ion Exchange Resin Materials for Fabricated with Chemical-biological Cloth by QFD (QFD 기법을 이용한 특정 유해가스 노출제어 이온선택성 보호복 소재개발연구)

  • Song, Hwa Seon;Koo, Il Seob;Kim, In Sik
    • Journal of Korean Society for Quality Management
    • /
    • v.43 no.3
    • /
    • pp.359-372
    • /
    • 2015
  • Purpose: Through studying the expert's and non-experts panel responses to the questions regarding the attributes of chemical-biological protection cloth quality in terms of the levels of customer demand and technical factors has been studied. We are applied to a QFD matrix with find out the relationship between the selective removal efficiency of chemical-biological cloth and the guidelines of technical approach. Methods: We fabricated several composite of ion-exchange resins with selectively permeable performance designed to facilities water vapor transport and selective adsorption of the harmful gases. With these materials, we characterized on the selectively permeable performance to identify ion-exchange resin with chemical-biological protective cloth. Results: Results showed that ion exchange materials possessed performance with selectively efficiencies as NH3, SOx, NOx and HCl gas. The selective adsorption amount of ammonia and hydrogen gases were $90-80{\mu}g/g$ with TRILITE SCR-BH sulfonated ion exchange resin. The PP non-woven/ion exchange resin adsorbent materials possessed performance with water vapor permeability were 1,100-1,350 g/m2/day, it's was two times high value compare with activated carbon. With these materials, we characterized selectively removal efficiency to identify new ion-exchange material with chemical-biological protective capability. Conclusion: This study shows that a QFD aids in deciding with of the adsorption parameters to optimized with chemical-biological protection cloth manufacturing.

Ion Exchange Membrane for Desalination by Electrodialysis Process: A Review (전기투석법에 의한 담수화용 이온교환막: 총설)

  • Sarsenbek, Assel;Rajkumar, Patel
    • Membrane Journal
    • /
    • v.32 no.2
    • /
    • pp.91-99
    • /
    • 2022
  • It is a global challenge to fulfill the demand for clean water at an affordable cost to all the strata of the population. Desalination of seawater as well as brackish water by the membrane separation process is a well-established and cost-efficient method. However, there is still inherent problem of membrane fouling, disposal of the reject as well as a capital-intensive process. While electrodialysis (ED) is a membrane-based separation process in which a driving force is the potential difference. The advantages of ED process are excellent efficiency and low operation cost. Ion exchange membrane (IEM) used in the ED process needs to have higher chemical and thermal stability along with excellent mechanical strength for long-term use without losing its efficiency. The ion exchange capacity of the ED membrane is largely dependent on the conductivity of IEMs. In this review, the modification strategy of the pristine membrane to enhance the stability and ion conductivity of cation exchange membrane (CEM) and anion exchange membrane (AEM) is discussed.

A Sanitary Survey on the Clean Water by Domestic Purifier (가정용 정수기의 수질에 대한 위생학적 조사 소견)

  • 채용곤
    • Journal of environmental and Sanitary engineering
    • /
    • v.5 no.1
    • /
    • pp.65-72
    • /
    • 1990
  • To study on the water quality of domestic purifier, twenty four samples of clean water by purifier and the raw water(tap water) were tested for biological and physico-chemical examination and were checked for style of purification and the period elapsed after changing of purification medium. The results were as follows; Biological and physico-chemical findings of raw water were not exceeded standard values. Average number of general bacteria,2.coli and pH in clean water were significantly higher than that of raw water(respectively, p<0.01), but mean contents of turbidity, chloride, nitrate and iron in clean water were significantly lower than that of raw water(respectively, p<0.01). In general count of bacteria and E.coli, a half of the clean water of ceramic filter and roverse osmosis style were exceeded standard values for drinking water. All of the pH of the ion exchange style clean water were exceeded standard values. But other findings were within standard values. In average bacterial counts and physico-chemical findings of clean water by purification style of purifier, clean water of ion exchange style purifier were lowest number of general bacteria and not detected in 2. coli. But other items were highest. The longer period elapsed after changing of purification medium were the higher contents of biological and physico-chemical findings of clean water.

  • PDF

A Review of Industrially Developed Components and Operation Conditions for Anion Exchange Membrane Water Electrolysis

  • Lim, Ahyoun;Cho, Min Kyung;Lee, So Young;Kim, Hyoung-Juhn;Yoo, Sung Jong;Sung, Yung-Eun;Jang, Jong Hyun;Park, Hyun S.
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.265-273
    • /
    • 2017
  • Solid-state alkaline water electrolysis is a promising method for producing hydrogen using renewable energy sources such as wind and solar power. Despite active investigations of component development for anion exchange membrane water electrolysis (AEMWE), understanding of the device performance remains insufficient for the commercialization of AEMWE. The study of assembled AEMWE devices is essential to validate the activity and stability of developed catalysts and electrolyte membranes, as well as the dependence of the performance on the device operating conditions. Herein, we review the development of catalysts and membranes reported by different AEMWE companies such as ACTA S.p.A. and Proton OnSite and device operating conditions that significantly affect the AEMWE performance. For example, $CuCoO_x$ and $LiCoO_2$ have been studied as oxygen evolution catalysts by Acta S.p.A and Proton OnSite, respectively. Anion exchange membranes based on polyethylene and polysulfone are also investigated for use as electrolyte membranes in AEMWE devices. In addition, operation factors, including temperature, electrolyte concentration and acidity, and solution feed methods, are reviewed in terms of their influence on the AEMWE performance. The reaction rate of water splitting generally increases with increase in operating temperature because of the facilitated kinetics and higher ion conductivity. The effect of solution feeding configuration on the AEMWE performance is explained, with a brief discussion on current AEMWE performance and device durability.

Numerical simulation on capillary absorption of cracked SHCC with integral water repellent treatment

  • Yao Luan;Tetsuya Ishida
    • Computers and Concrete
    • /
    • v.34 no.1
    • /
    • pp.123-135
    • /
    • 2024
  • Strain-hardening cement-based composites (SHCC) under cracked condition exhibits remarkable capillary absorption due to water ingress from multiple cracks. Surface treatment using water repellent agents is an effective way for improving water resistance of SHCC, but the water resistance may remarkably decrease when cracks penetrate impregnation depth. Another way is to add water repellent agents directly into the mixture, offering SHCC integral water repellency even if cracks form later. However, although integral water repellent treatment has been proved feasible by previous studies, there is still lack of simulation work on the treated SHCC for evaluating its durability. This study presents a simulation method for capillary absorption of cracked SHCC with integral treatment based on a multi-scale approach proposed in the authors' previous work. The approach deals with water flows in bulk matrix and multiple cracks using two individual transport equations, respectively, whereas water absorbed from a crack to its adjacent matrix is treated as the mass exchange of the two equations. In this study, the approach is enhanced for the treated SHCC by integrating the influencing of water repellency into the two transport equations as well as the mass exchange term. Using the enhanced approach, capillary absorption of water repellent SHCC under cracked condition is simulated, showing much more reduced water ingress than the untreated concrete, which is consistent with total absorption data from previous tests. This approach is also capable of simulating water spatial distribution with time in treated SHCC reasonably.