• Title/Summary/Keyword: Water discharge capability

Search Result 46, Processing Time 0.027 seconds

Response Time Index and Suppression Capability of Standard and Quick Response Sprinkler Head (표준형 및 속동형 스프링클러헤드의 반응시간지수와 소화성능)

  • 정길순;이병곤
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.59-70
    • /
    • 1998
  • In this study, response time index(RTI) of standard and quick response type sprinkler head are measured and compared through ramp and plunge test in heated wind tunnel. Also discharge rate and water distribution, actual delivered density(ADD), fire test with wood cribs are performed to compare the fire suppression capability and the operation time and temperature between standard and quick response type sprinkler head.

  • PDF

Discharge Coeficient Analysis according to Flow Condition for Radial Gate Type (Radial Gate 형식의 배수갑문 흐름조건별 유량계수 검토)

  • Park, Yeong-Wook;Hwang, Bo-Yeon;Song, Hyun-Gu
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.306-312
    • /
    • 2005
  • Gates for the purpose of drainage are classified following the types of structure as: Radial Gate, Sluice Gate, Rolling Gate, Drum Gate. In many cases of the reclamation project the sluice type of gates are applied. Different from this general trend, however the radial type of gate was adopted in the Saemangeum project. In this case the discharge coefficients which are used for the sluice type of gate was applied. To estimate the correct amount of discharge which will be evacuated through the gates, therefore the proper discharge coefficients should be estimated before the operation of the gates. The discharge coefficients were estimated through the physical hydraulic modeling, and we got the results as: $0.72{\sim}0.84$ for the submerged condition on the both sides of upstream and downstream, $0.62{\sim}0.83$ for the free surface condition on the downtream side only, and $1.04{\sim}1.12$ for the free surface condition on the both sides of upstream and downstream. The discharge coefficients obtained from the experiments are greater than those of the sluice gates in the design criteria. From the results of the study we may expect that in the Saemangeum project the radial gates could evacuate larger amount of discharge than the originally designed discharge, so that we may sure that the Saemangeum gates have enough capability to control the evacuation of water not only in the usual period but also in the flooding season.

  • PDF

Prediction of Water Quality in Haenam Estuary Reservoir Using Multiple Box Model (I) -Development and Application of Water Quality Subroutines- (Multiple Box 수질모형에 의한 해남호 수질예측 (I) - 수질부 모형의 개발과 적용 -)

  • 신승수;권순국
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.3
    • /
    • pp.116-129
    • /
    • 1990
  • A rational management of water resources in estuary reservoirs necessiates the prediction of water quality. In this study, a multiple box model for the water quality prediction was developed as a tool for the purpose of examining an adequate way to improve and maintain the water quality. Some submodels that are suitable for simulating the mixing behavior of pollutant materials in a lake were considered in this model. The model was appiled for predicting water qualities of Haenam Esturay Reservoir. The result from this study can be summarized as follows : 1.A water quality simulation model that can predict the 10-day mean value of water qualities was developed by adding some submodels that simulate the concentrations of chlorophyll-a, BOD, T-P and T-N to the existing Multiple Box Model representing the mixing and circulating of materials by the hydarulic action. 2.As input data for the model developed, the climatic data including precipitation, solar radiation, temperature, cloudness, wind speed and relative humidity, and the water buget records including the pumping discharge and the releasing discharge by drainage gate were ollected. The hydrologic data for the inflow discharge from the watershed was obtained by simulation with the aid of USDAUL-74/SNUA watershed model. Also the water quality data were measured at streams and the reservoir. 3.As a result of calibration and verification test by using four comonents of water quality such as Chlorophyll-a, BOD, T-P and T-N, it was found that the correlation coefficeints between the observed and the simulated water qualities showed greater than 0.6, therefore the capability of the model to simulate the water quality was proved. 4.The result based on the model application showed that the water quality of the Haenam Estuary Reservoir varies seasonally with the harmonic trend, however the water quality is good in winter and get worse in summer. Also it may be concluded that the current grarde of water quality in the Heanam Esutary Reservoir is ranked as grade 4 suitable only for the agricultutal use.

  • PDF

Development of Kinematic Wave-based Distributed Model for Flood Discharge Analysis (홍수유출해석을 위한 운동파기반의 분포형모형 개발 및 적용)

  • Park, Jin-Hyeog;Hur, Young-Teck
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.5
    • /
    • pp.455-462
    • /
    • 2008
  • In this research, a distributed rainfall-runoff model based on physical kinematic wave was developed to simulate temporal and spatial distribution of flood discharge considering grid rainfall and grid based hydrological information. The developed model can simulate temporal change and spatial distribution of surface flow and sub-surface flow during flood period, and input parameters of ASCII format as pre-process can be extracted using GIS such as ArcGIS and ArcView. Output results of ASCII format as post-process can be created to express distribution of discharge in the watershed using GIS. The Namgang Dam Watershed was divided into square grids of 500m resolution and calculated by kinematic wave into an outlet through channel networks to review capability of the developed model. The model displayed precise results to be compared to the hydrograph.

Study on Establishment of the Industrial Wastewater Effluent Limitations Based on Best Practicable Control Technology Currently Available - Case Study for the Pulp, Paper and Paper Board Manufacturing (실용 가능한 최적처리기술에 근거한 산업폐수 배출허용기준 설정 연구 - 펄프.종이 및 종이제품 제조시설 적용 사례)

  • Kim, Jaehoon;Shin, Jinsoo;Lee, Chulgu;Lee, Jungyoung;Lee, Youngsun;Yu, Soonju
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.608-614
    • /
    • 2012
  • The effluent limitation of industrial wastewater is based on uniform regulatory criteria for effluent discharge facilities of all in Korea. But, an individual effluent limitation on each effluent discharge facility is widely applicable for regulation of industrial wastewater in US.EPA. To decide an individual effluent limitation, TBEL (Technology-based effluent limitation) and WQBEL (Water quality-based effluent limitation) are used. TBEL is based on the capability of a treatment technology to reduce the pollutants. WQBEL is based on ambient water quality standards. In this study, TBEL were derived for the pulp, paper and paper board manufacturing based on best practicable control technology currently available. It was suggested that effluent limitations were $BOD_5$ 4.7 mg/L, $COD_{Mn}$ 44.3 mg/L, SS 13.2 mg/L, TN 1.4 mg/L, TP 0.15 mg/L and best practicable control technology currently available (BPT) was neutralization, activated sludge treatment and coagulation and sedimentation for the pulp, paper and paper board manufacturing.

A Development of Real Time Artificial Intelligence Warning System Linked Discharge and Water Quality (II) Construction of Warning System (유량과 수질을 연계한 실시간 인공지능 경보시스템 개발 (II) 경보시스템 구축)

  • Yeon, In-Sung;Ahn, Sang-Jin
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.7 s.156
    • /
    • pp.575-584
    • /
    • 2005
  • The judgement model to warn of possible pollution accident is constructed by multi-perceptron, multi layer neural network, neuro-fuzzy and it is trained stability, notice, and warming situation due to developed standard axis. The water quality forecasting model is linked to the runoff forecasting model, and joined with the judgement model to warn of possible pollution accident, which completes the artificial intelligence warning system. And GUI (Graphic User Interface) has been designed for that system. GUI screens, in order of process, are main page, data edit, discharge forecasting, water quality forecasting, warming system. The application capability of the system was estimated by the pollution accident scenario. Estimation results verify that the artificial intelligence warning system can be a reasonable judgement of the noized water pollution data.

A Study on the Application and Design Procedure of Multi-Purpose Wet Detention Ponds for Improving Water Quality - Case Study of NamAk New Town Development Area - (다목적 저류지의 수질개선을 위한 설계과정 및 적용에 관한 연구 - 남악 신도시 개발지를 대상으로 -)

  • Woo, Chang-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.7 no.1
    • /
    • pp.97-109
    • /
    • 2004
  • The disposal of stormwater is one of the major problems in urban water management. One method of reducing peak runoff rates and other detrimental impacts of stormwater is detention storage. Detention ponds as a water quality control alternatives have been investigated by a number of researchers. Recognizing multiple roles such as flood peak attenuation, pollution removal and aesthetic enhancement, the design and management of detentions ponds deserve more research. The purpose of this research is to establish design criteria wet detention ponds to improve water quality. Water quality in detention pond discharge might be improve with physical, chemical and biological alterations. Physical alteration was focused in this study. There are several methods for estimating the suspended solid control capability of wet detention ponds. Existing models of suspended solids removal are based on sedimentation and gravity settling theory. The pollutant trap efficiency of pond is a function of several interrelating factors. Detention time is the most important factor, because it determine gravity settling quantities of pollutants. Desirable modification of physical factors for improvement of water quality in wet detention ponds are volume ratio, area ratio, length to width ratio, depth, out let location, bottom soil type. In order to apply design procedure in actual site, Namak new town development area was selected.

Numerical simulation of air discharged in subcooled water pool

  • Y. Cordova ;D. Blanco ;Y. Rivera;C. Berna ;J.L. Munoz-Cobo ;A. Escriva
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3754-3767
    • /
    • 2023
  • Turbulent jet discharges in subcooled water pools are essential for safety systems in nuclear power plants, specifically in the pressure suppression pool of boiling water reactors and In-containment Refueling Water Storage Tank of advanced pressurized water reactors. The gas and liquid flow in these systems is investigated using multiphase flow analysis. This field has been extensively examined using a combination of experiments, theoretical models, and Computational Fluid Dynamics (CFD) simulations. ANSYS CFX offers two approaches to model multiphase flow behavior. The non-homogeneous Eulerian-Eulerian Model has been used in this work; it computes global information and is more convenient to study interpenetrated fluids. This study utilized the Large Eddy Simulation Model as the turbulence model, as it is better suited for non-stationary and buoyant flows. The CFD results of this study were validated with experimental data and theoretical results previously obtained. The figures of merit dimensionless penetration length and the dimensionless buoyancy length show good agreement with the experimental measurements. Correlations for these variables were obtained as a function of dimensionless numbers to give generality using only initial boundary conditions. CFD numerical model developed in this research has the capability to simulate the behavior of non-condensable gases discharged in water.

Performance evaluation of a subsurface drainage culvert system in converted paddy fields

  • Do, Jong Won;Park, Jongseok;Kim, Hyuntai;Lee, Kwangya;Shin, Hyungjin
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.2
    • /
    • pp.263-273
    • /
    • 2020
  • With the change of the agricultural environment (increased rice production, decreased rice consumption, and rice production policies), converting paddy fields into upland fields is an increasing trend. In terms of conversion into upland fields, subsurface drainage is one of the most important factors for good field crop growth. This study evaluates the performance of a subsurface drainage culvert system in paddy fields and reclaimed lands. The obtained results are briefly summarized as follows: 1) After a comparative evaluation of several subsurface drainage culvert systems, including excavated subsurface drainage and non-excavated subsurface drainage types, type 3 (non-excavated, perforated drain pipe 50 mm, filter mat B50 cm, subsoiling 70 cm and culvert spacing 5 m) shows relatively high values among four types in terms of effectiveness (subsurface discharge capability) and economic efficiency (construction cost). 2) Type 3 has proven that it is suitable for design standards of discharge capacity through field tests performed in paddy fields (three sites: Gong-geom, Gae-san, Juk-san) and reclaimed lands (two sites: Gum-ho, Mi-am). 3) In the experiment of Sesamum indicum growth according to the existence of a drainage system, Sesamum indicum growth with a subsurface drainage culvert system had good value in terms of plant shoot and root length, shoot fresh and dry weight, and root fresh and dry weight).

Development and assessment of water management resilience of mid-small scale tributaries (지류 중소하천의 물관리 탄력성 평가지수 개발 및 평가)

  • Park, Jung Eun;Lee, Eul Rae;Lim, Kwang Suop
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.2
    • /
    • pp.95-106
    • /
    • 2016
  • Water Management Resilience Index (WMRI) was developed as a policy measure of adaptability to withstand water stresses and to set up water management strategies mainly in mid-small scale tributaries, and then evaluated on 117 sub-basins in South Korea. The index consists of 3 sub-indices such as vulnerability, robustness and redundancy sub-indices, each including indicators of 3 sectors: water use, flood mitigation, and river environment. Total number of indicators selected for the index was 31. Taking into account the stream order and control capability of river flow discharge, sub-basins were categorized into 3: 1 for mainstreams of lower large dams, 2 and 3 for tributaries, respectively without and with flow discharge regulation. As a result of the evaluation, resilience index scores in Category 2 and 3 are much lower than that of Category 1, especially with very poor score of redundancy. Although there was no significant difference between mainstream and tributaries in vulnerability and robustness sub-indices, results of redundancy sub-index in tributaries were lower than those in mainstream. Thus, it is conceived that the variety of water management schemes should be considered to improve their resilience in the face of future uncertainty. Addressing comprehensive stability of river basin against internal and external impacts, WMRI in this study can also be used for the prioritization of water management plans.